Call Us
Send Inquiry    Call Me Free
Testing the Barrier Properties of Pet Food Packaging

Testing the Barrier Properties of Pet Food Packaging

50000 USD ($)/Set

Product Details:

  • Mounting Type Benchtop
  • Port Size DN15
  • Interface Type RS232/USB
  • Operating Voltage 220V AC
  • Application Pet food packaging barrier property analysis
  • Specimen Size 108 mm x 108 mm
  • Power Supply 220V, 50Hz
  • Click to View more
X

Testing the Barrier Properties of Pet Food Packaging Price And Quantity

  • 50000 USD ($)/Set
  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set

Testing the Barrier Properties of Pet Food Packaging Product Specifications

  • 120 kg
  • Pet food packaging barrier property analysis
  • DN15
  • 220V AC
  • RS232/USB
  • Benchtop
  • Barrier property tester
  • < 5 seconds
  • 0.01 10,000 cc/m24h
  • 0 100 mm
  • 0.001 cc/m24h
  • Up to 300 mm
  • 220V, 50Hz
  • 108 mm x 108 mm
  • 10C 40C
  • 350 mm
  • 20 90% RH
  • Automatic
  • 50 Hz
  • High sensitivity, stable performance, automatic operation
  • 1 3 simultaneously
  • 1% of reading
  • 0.1 500 mm/min
  • LCD digital display
  • 0.6 MPa
  • Testing oxygen and water vapor transmission rates
  • 0.01 10,000 cc/m24h
  • Microprocessor-based automatic control
  • 0 50 N

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Brand new rainbow bridge structural test cell and 360 air circulation constant temperature technology ensure better temperature stability.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • The test cell is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.

High Efficiency 6 Test Cells

  • Independent six sets of 50cm2 standard area test cells, which is three times the traditional oxygen transmission rate test instrument.
  • Six samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 6.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • Intelligent test cell hood which opens and closes automatically with sound and light alert.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Space Saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving laboratory space.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C406H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.02 200
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.02 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.02 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.02 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.15
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%, 100%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 6 test chambers
Specimen Size 4.6 x 4.6i1411.7cm11.7cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Real-Time Data & Efficient Reporting

Experience automated test cycles with real-time data output and comprehensive report generation, enabling fast review and documentation of barrier property results for pet food packaging. The included Windows-compatible software allows seamless data management and analysis, promoting productivity and precision in laboratory environments.


Automatic Calibration for Accurate Results

Benefit from automatic calibration using standard gases or films, which ensures measurement accuracy and reduces manual intervention. The equipment maintains consistent performance, backed by CE and ISO 17025 certifications, giving you confidence in every test result.


Fast Sample Preparation & Versatile Testing

Prepare samples in under three minutes and select from test cycles ranging between 30 minutes and 10 hours, adaptable to different barrier types and testing requirements. The system supports simultaneous testing of up to three specimens, enhancing laboratory throughput and flexibility.

FAQ's of Testing the Barrier Properties of Pet Food Packaging:


Q: How does the barrier property tester deliver real-time data and generate test reports?

A: The tester features integrated software for Windows OS, which continuously captures and displays real-time measurement data. After each cycle, comprehensive test reports are automatically generated, detailing key parameters such as transmission rates and sample specifics.

Q: What is the process for preparing samples, and how long does it take?

A: Sample preparation is streamlined and takes less than three minutes. You simply cut the packaging material to the required 108 mm x 108 mm size, mount it in the specimen holder, and the equipment manages the rest through its automated cycle.

Q: When should I use automatic calibration, and how does it work?

A: Automatic calibration should be performed before routine testing to ensure precision. The equipment uses standard calibration gases or films and runs internal checks automatically, guaranteeing consistent accuracy without manual adjustments.

Q: Where can this tester be used, and what safety certifications does it have?

A: The device is suitable for use in manufacturing, quality control laboratories, and research centers focused on pet food packaging. It is certified with CE and ISO 17025, ensuring safe operation and compliance with international standards.

Q: What types of barrier properties does this equipment measure?

A: This tester measures both oxygen and water vapor transmission rates, critical for evaluating the protective qualities of pet food packaging and ensuring product integrity and shelf life.

Q: How accurate are the measurements and what sensors do the device use?

A: Measurements have an accuracy of 1% of the reading, utilizing high-sensitivity electrochemical and infrared sensors, which provide reliable and precise barrier property analysis.

Q: What are the key benefits of using this automated barrier property tester?

A: The main benefits include rapid sample preparation, comprehensive real-time data, automatic calibration, multi-specimen capacity, low noise operation, and compliance with essential safety standards for efficient and dependable packaging analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.