Product Description
Product FeaturesNote1
Innovative Design of Automatic Lifting of Sled & Upgraded Testing Accuracy and Repeatability
- Two test modes are available i.e. coefficient of friction and peel test
- Innovative automatic lifting of sled ensures accurate still time of the sled and guarantees the high repeatability of coefficient of friction test results
- The sliding plane and the sled are treated by degaussing and remanence detection which effectively reduce the system errors
- Wide range and high-precision of automatic temperature control system to support tests at different temperatures
- Force measuring system is supplied by global well-known supplier, the testing accuracy is higher than 0.5%FS, with better repeatability, multiple test ranges for choice
- Intelligent designs including position restriction, overload protection and auto reset guarantee the safe operation
- The instrument conforms to multiple ISO, ASTM and GB standards
High-end Easy-to-Use Embedded Computer Controlled System
- Large touch screen tablet is easy to view and operate
- Brand new software which is easy to use simplifies the testing operations
- The instrument supports comparative analysis of group of test data, with unit conversion features
- USB ports and net port for data transmission and external connection
- The instrument conforms to the requirements of GMP (optional)
- Labthinks unique data security system,separates the test data from the computer to avoid the risks caused by computer virus
- Labthinks unique DataShiledTM System for data management and connecting with information system (optional)
Test StandardNote1
ISO 8295, ISO 8510-2, ASTM D1894, ASTM D4917, ASTM D3330, TAPPI T816, TAPPI T549, GB 10006,GB/T 2790,GB/T 2791,GB/T 2792
Applications
| Basic Applications |
- Plastic Films and Sheets
Coefficient of static and dynamic friction tests of plastic films and sheets
|
- Paper and Paperboard
Coefficient of static and dynamic friction tests of paper and paperboard
|
- Textiles, Non-woven Fabrics and Woven Bags
Coefficient of static and dynamic friction tests of textiles, non-woven fabrics and woven bags
|
- Rubber
Coefficient of static and dynamic friction tests of rubber products
|
- Aluminum Foils and Aluminum Foil Composite Films
Coefficient of static and dynamic friction tests of aluminum foils, aluminum foil composite films and other metal products
|
- Printing Matters
Coefficient of static and dynamic friction tests of printing matters
|
| Extended Applications |
- High Temperature Test
Coefficient of static and dynamic friction tests at higher temperature than room temperature
|
- Wood and Flooring
Coefficient of static and dynamic friction tests of wood and flooring
|
- Photographic Films
Coefficient of static and dynamic friction tests of photographic films
|
- Screen of Mobile Phone and Leather
Coefficient of static and dynamic friction tests of mobile screens against the leather products
|
- Adhesives
Peeling test of the adhesive products
|
- Medical Adhesives
Peeling test of medical adhesives e.g. adhesive bandages and plasters
|
- Protection Films
Peeling test of protection films for mobile phones or computers
|
- Magnetic Cards
Peeling test of the films and magnetic cards
|
Technical SpecificationsNote2
| Specifications |
C620H Friction / Peel Tester |
| Test Range |
0 5 N (standard) 0 10 N, 0 30 N, 0 50N, 0 100N (optional) |
| Force Accuracy |
Displayed Value 0.5% (10%FS-100%FS) 0.05%FS (0%-10% of the load cell range) |
| Force Resolution |
0.001 N |
| Test Speed |
0 500 mm/min (Any integer within this range can be set) |
| Speed Accuracy |
Displayed Value 0.5% (1%100% of maximum speed) |
| Stroke |
10 300 mm |
| Displacement Resolution |
0.01 mm |
| Test Temperature |
Room Temperature 100C |
| Temperature Variation |
0.2C |
| Temperature Accuracy |
2C (Single point calibration, within effective area of the test platform) |
| Test Platform |
400mm150mm |
| Specimen Thickness |
2 mm |
| Sled |
Weight: 200g Size: 63.5mm63.5mm Customization is available |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Instrument Dimension |
635 mm (L) 300 mm (W) 250 mm (H) |
| Net Weight |
25 kg |
Configurations
- Standard Configurations
- Instrument, Tablet, COF Test Fixture, Peel Test Fixture, 200g Sled, Sampling Block
- Optional Parts
- Standard Pressure Roller, Test Plate, Printer, Air Compressor, GMP System, DataShieldTM Note3
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Advanced Peeling Strength AnalysisEngineered for precise and repeatable tests, this instrument utilizes a 180 peel configuration and programmable settings to deliver consistent results. Researchers and manufacturers benefit from electronic auto-calibration and selectable measuring units, ensuring reliable data across multiple specimens and testing conditions. Its robust stepper motor drive and intuitive digital interface make it ideal for quality control and packaging applications.
User-Friendly Digital Controls and Data HandlingEquipped with a digital LCD display, USB and RS232 data ports, and the ability to store up to 1000 test results, this instrument simplifies test management and traceability. Programmable test times and digital force display empower users with flexibility, while semi-automatic operation streamlines workflows and maintains process efficiency.
Safety, Compliance, and VersatilityWith overload protection and an emergency stop function, user safety is prioritized throughout testing. This instrument complies with international standards such as ASTM F88 and ISO 11334. Its flexible mounting and clamping options make it suitable for various laminated film types, supporting robust quality assurance for manufacturers and exporters.
FAQ's of Laminated Film Peeling Strength Measuring Instrument:
Q: How do I operate the Laminated Film Peeling Strength Measuring Instrument for optimal results?
A: Ensure specimens are cut to the specified size (100 mm x 30 mm) and placed securely using manual or pneumatic clamps. Use the digital microprocessor control to select test parameters such as speed (50 mm/min) and test time (1-999 sec). Perform tests in a dust-free environment for maximum accuracy.
Q: What types of data outputs are available with this instrument?
A: Test results can be exported via USB or RS232 interfaces, allowing compatibility with various data management systems. The instrument also stores up to 1000 results internally for easy access and review.
Q: When should the instrument be recalibrated, and how is calibration performed?
A: Thanks to its electronic auto-calibration feature, the instrument performs self-calibration as needed. It is advisable to check calibration status periodically or whenever there is a significant change in ambient conditions.
Q: Where is this peeling strength tester most commonly used?
A: This equipment is widely used in packaging film analysis, laboratory research, and quality control environments, particularly where compliance with ASTM F88 and ISO 11334 is required.
Q: What is the process for conducting a peel strength test with this system?
A: Secure the specimen in the clamps, program the test parameters, and initiate the peel test via the digital interface. The instrument's stepper motor drives the peeling motion at a controlled speed, collecting force data until the test concludes or reaches 250 mm stroke length.
Q: How does programmable speed and force display benefit users?
A: Programmable speed ensures consistent and repeatable testing, while the digital force display delivers real-time measurement feedback. This combination enhances accuracy for quality assurance and makes result interpretation more straightforward.
Q: What ambient operating conditions are recommended for the instrument?
A: Optimal performance is achieved in a dust-free environment, within temperature ranges of 10C to 30C and relative humidity between 40% and 80%.