Product Description
Product FeaturesNote1
Ten Test Modes to Meet Various Testing Demands
- Ten independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, puncture test of rubber closure and puncture retention force test, etc. at users choice
- The instrument supports bidirectional testing modes, which can be used for puncture test of rubber closure and breaking force test of ampoule and test speed can be adjusted freely
- Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users
Excellent Testing Mechanism & Improved Test Accuracy
- Force measuring system is supplied by top global supplier, ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
- Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
- Global renowned brand pneumatic control system supports pneumatic specimen clamping, avoids the specimen slipping and guarantees the accuracy of test data
High-end, Secure and Easy-to-Use Embedded Computer-controlled System
- The instrument is integrated with software requiring no external computer
- The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
- Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
- The instrument is equipped with USB ports and Internet ports for convenient data transmission.
- Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.
Test StandardNote1
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
C610M is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:
| Basic Applications |
|
|
- Test of Tensile Strength and Elongation Rate
|
- Test of Tensile Strength at Break
|
|
|
|
|
|
|
|
|
- Tensile Strength Test at Defined Elongation
|
Extended Applications (Additional Accessories Required) |
- Puncture Test of Hypodermic Needles in Artificial Skin
|
|
- Puncture Test of Infusion Bags
|
- Puncture/Pullout Test of Flexible Rubber Closures
|
- Opening Resistance Test of Combined Covers
|
- Tear Test of ZD - Type Caps
|
- Opening Force Test of Oral Liquid Caps
|
- Puncture/Pullout Test of Oral Liquid Caps
|
- 90 Degree Pullout Test of Infusion Bag Caps
|
- Pullout Test of Infusion Bag Caps
|
- 23 Degree Pullout Test of Bottle Caps
|
- Puncture/Pullout Test of Bottle Caps or Rubber Closures
|
- 90 Degree Peel Test of Adhesive Tapes
|
- Tear Resistance Test of Adhesive Binding Books
|
- 90 Degree Peel Test of Water-soluble Plasters
|
- Tear Resistance Test of Adhesives
|
- Adhesive Strength Test (soft)
|
- Adhesive Strength Test (hard)
|
- Peel Test of Flexible Tube Caps
|
- Removal Force of Pipes and Pipe Joints
|
- Pullout Test of Cosmetic Brush Hair
|
- Pullout Test of Tooth Brush Hair
|
- Tensile Strength of Ropes at Break
|
- Opening Force Test of Jelly Cups and Yogurt Cups
|
|
|
- Pullout Test of Rubber Stoppers
|
- 45 Degree Peel Test of Bottle Membranes
|
- Tensile Strength of Sealing Bags
|
- Peel Test of Magnetic Cores
|
- 90 Degree Peel Test of Magnetic Cards
|
- Tear Resistance of Heat Sealing Films
|
- Separating Force of Protection Films
|
- Peel Test of Release Paper
|
- Tear Test Using Trouser Method
|
- Unwrapping Force of Adhesive Tapes
|
- Compressive Resistance of Plastic Bottles
|
|
|
- 135 Degree Peel Test of Plugs
|
- Peeling Grips of Floating Rollers
|
|
|
|
|
|
|
- Tensile Strength of Contact Lenses at Break
|
- Compression Resistance of Jelly Cups
|
- Compression Resistance of Package
|
- Compression Resistance of Sponge
|
|
Technical Specifications
| Specifications |
C610M Auto Tensile Tester |
| Load Cell Capacity |
500 N (standard) 50 N, 100 N, 250 N, 1000 N (optional) 5N (Customization available) |
| Accuracy |
0.5% of indicated value (2%FS 100%FS) 0.01%FS (0% 2%FS) |
| Resolution |
0.001 N |
| Test Speed |
0500 mm/min |
| Speed Accuracy |
0.5% of indicated value |
| Number of Specimens |
1 |
| Specimen Width |
30 mm (Standard Grip) |
| 50 mm (Optional Grip) |
| Clamping Way |
Pneumatic Specimen Clamp |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 MPai1472.5psii101.5psii14 |
| Stroke |
950 mm (customization available for 1200mm) |
| Instrument Dimension |
450 mm (L) x 450 mm (W) x 1410 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
95 kg |
Configurations
- Standard Configurations
- Instrument (with embedded software), LCD Monitor, Keyboard, Mouse, Pneumatic Sample Girps
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Air Compressor
- Note
- 1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Advanced Seal Strength Testing PrecisionThe Heat Sealing Strength Tester offers accurate and reproducible measurement of seal strength in medical plastic packaging. Powered by microcomputer control and precision load cell, it supports peal, tensile, and shear test modes to comprehensively evaluate packaging integrity. The device's capacity (up to 100 N) and rapid response (0.5 s) ensure swift and reliable results, crucial for medical standard compliance and product safety.
Flexible Operation and Data ManagementFeaturing both manual and auto calibration, users can easily maintain accuracy. Test results are displayed on a digital LCD, stored internally, and exported via USB or printed directly. The multi-language support (English/Chinese) allows convenient operation for global teams. With adjustable test speeds and widths, laboratories can tailor assessments for specific packaging requirements, maximizing operational flexibility.
Safety and Compliance AssuranceBuilt with robust overload protection and emergency stop features, this tester safeguards operators during demanding tests. Its compliance with ASTM F88 and ISO 8827 ensures that medical plastic packaging meets international standards for heat seal strength. The quiet operation (70dB) and ergonomic bench-top mounting make it ideal for both production and laboratory environments.
FAQ's of Heat Sealing Strength Testing for Medical Plastic Vacuum Forming Packaging:
Q: How does the pneumatic clamping method enhance heat seal strength testing for medical packaging?
A: The pneumatic clamping method delivers consistent force application for up to three specimens simultaneously, reducing human error and ensuring more accurate, repeatable seal strength measurements for medical plastic vacuum formed packages.
Q: What types of tests can be performed with this Heat Sealing Strength Tester?
A: This equipment supports peel, tensile, and shear tests. Each mode targets different aspects of seal integrity, providing comprehensive data on the performance and durability of medical plastic packaging heat seals.
Q: When should calibration be performed on this tester, and what options are available?
A: Calibration should be conducted before initial use, periodically as part of routine maintenance, or after major servicing. The machine allows both manual and automatic calibration modes to ensure measurement accuracy within 1% full scale.
Q: Where can the test results be viewed and exported from the device?
A: Test results are displayed on the LCD digital screen. Data can also be printed directly or exported via USB, and the device offers RS232 interface connectivity for integration with laboratory management systems.
Q: What is the process for measuring seal strength using this equipment?
A: Specimens are mounted using pneumatic clamps, test parameters (speed, width, mode) are set, and the microcomputer controls the test cycle. Seal strength is measured using the precision load cell, with results available in real time on the display and for export.
Q: How does the tester support multi-language functionality?
A: The interface can be switched between English and Chinese, facilitating easy operation and training for teams in different regions.
Q: What benefits does this tester provide for manufacturers and exporters of medical plastic packaging?
A: Manufacturers and exporters benefit from standardized, accurate testing that ensures compliance with ASTM F88 and ISO 8827. Features such as customizable test parameters, data storage, and print/export options support efficient quality control and certification processes.