Product Description
Featuresnote1
Batch Testing
- Equipped with fully-automatic gravity fed sample feeder, which is Labthinks latest scientific and technological achievement that can facilitate continuous testing of 20 to 120 samples.
- A & B dual-channel design can test samples of two different specifications simultaneously.
- The target vacuum degree can be set by the operator to meet testing requirements of different samples.
- Dual methods of vacuum decay and pressure decay provide the flexibility to accommodate various types of package samples.
Precise Data
- Advanced pressure detection technology, using world renowned components for data stability which is not affected by ambient environment.
- Advanced microflow automatic flow control technology that can accurately simulate different sizes of leakage holes without manual adjustment.
- Both the differential pressure transducer and flow meter are traceable to NIST.
- The system can achieve a higher test repeatability of 1um.
Intelligent Control
- 15.6" embedded touch tablet computer with Windows OS.
- New longitudinal interface layout, and easy to use graphic user interface.
- Automatic alarm, automatic capture, automatic collection of unqualified samples.
- The pressure curve is displayed in real time, and the test results are counted automatically.
- Leakage rates are calculated automatically.
- The system is equipped with various sensors as intelligent reminders for safer operation and control.
- Universal printer can be connected for test results output.
- The system features embedded with USB and network ports to facilitate the external access and data transmission of the system, which can be upgraded remotely
Security Compliance
- Verified by compensation and calibration methods.
- The leak tester meets GMP requirements for data traceability and meets the needs of the pharmaceutical industry.
- User operation permission is managed at multiple levels, and the permission content can be configured on demand.
- Electronic signature is designed according to the standard requirements of 21 CFR Part11.
Test Principle
The sample is placed in the sample feeder and automatically delivered into the test cell. The leak rate and other results can be calculated and obtained by analyzing pressure changes measured by the sensor.
Reference Standards
ASTM F2338, YY-T 0681.18, and USP<1207>
Applications
| Basic Applications |
Vials |
Various vial sealing test. |
| Extended Applications |
Ampoule |
Various ampoule bottle sealing tests. |
| Cartridge Bottles |
Various cartridge bottle sealing tests. |
| Injection bottles |
Various injection bottles sealing test. |
Technical Parameters
Table 1: Test Parameters Note2
| Parameter\Model |
C690H |
| Testing Range |
um(Reference aperture size USP1207) |
38great leakage |
| Detection Lower Limit |
um |
3 |
| Resolution |
um |
0.1 |
| Repeatability |
um |
1 |
| Pressure Range |
kPa |
-1000100 |
| Extended Functions |
21 CFR Part11 |
Optional |
| GMP computer system requirements |
Optional |
Table 2: Technical Specifications
| Testing Cell |
1 set for A group and 1 set for B group |
| Sample Feeder |
1 set for A group and 1 set for B group |
| Sample Size |
45 mm80mmNote3 |
| Sample Quantity |
20120 pieces |
| Gas Specifications |
Compressed Air (Gas source is provided by the user) |
| Gas Source Pressure |
40.6 PSI / 500 kPa |
| Port Size |
6 mm Polyurethane tube |
| Dimensions |
33.4 H x 19.6 W x 28.7 D (85cm 50cm 73cm) |
| Power |
120VAC10% 60Hz / 220VAC10% 50Hzselect one from the two |
| Net weight |
209Lbs (95kg) |
Product Configuration
| Standard Configuration |
Mainframe, embedded tablet computer, software, flow meter, European vacuum pump, 6 mm polyurethane tube |
| Customization |
Test cell and sample feeder of group A, test cell and sample feeder of group B, negative standard reference sample and positive standard reference sample designed according to sample specifications |
| Optional Parts |
GMP computer system requirements, 21 CFR Part11, air compressor, IQ/OQ/PQ documents |
Note 1: The described product characteristics are subject to the specific annotation of the "Technical Parameters" table.
Note 2: The parameters in the table are measured in the Labthink laboratory by professional operators according to the requirements and conditions of the relevant laboratory environmental standards.
Note 3: Group C test cell can be customized for samples beyond the "Sample Size", but the lower detection limit and test range will change according to the sample size, and the actual delivery shall prevail.
Comprehensive Leak Testing for Cosmetic PackagingEnsure your cosmetic products packaging remains uncompromised with this non-destructive leak tester. Utilizing compressed air or gas as a test medium, it supports specimen sizes up to 150 mm and tests up to three items per cycle. Fast response time (1 s), adjustable cycle times, and intuitive touch panel controls make daily operation straightforward for QC teams. The equipment readily adapts to various packaging types with included sealing fixtures and supports both automatic and manual operating modes.
Compliance and Reliable Data ManagementBuilt to meet ISO 11607 and related cosmetic packaging standards, this tester safeguards your quality and regulatory compliance. Data integrity is ensured through internal memory that records up to 500 test results, enabling traceability and process validation. Calibration is user-adjustable and recommended annually, helping maintain consistent measurement accuracy and reliability throughout its service life.
FAQs of Ensuring Cosmetic Product Integrity with Non-Destructive Testing Equipment:
Q: How does the cosmetic product leak tester work for non-destructive integrity evaluation?
A: The tester uses compressed air or gas to pressurize cosmetic packaging within an enclosed chamber or fixture. By monitoring pressure changes with a high-precision sensor, it detects leaks without damaging the sample. The microprocessor-based control system provides quick, adjustable test cycles, and the results are shown on a digital LCD display.
Q: What types of cosmetic packaging can be tested with this equipment?
A: This device is designed for use with a wide variety of cosmetic packaging and containers, accommodating specimen sizes up to 150 mm. It supports bottles, tubes, jars, and other common packaging formats thanks to the included sealing fixtures, making it suitable for manufacturers, suppliers, and quality assurance teams.
Q: When should calibration and maintenance be performed on this tester?
A: Calibration is recommended annually to ensure ongoing accuracy, but the system allows for user-adjustable calibration if needed. Routine maintenance is straightforward, as the tool-free design enables quick servicing without specialized equipment, minimizing downtime and ensuring reliable operation.
Q: Where can the testing process be carried out ideally?
A: Testing should be conducted in a controlled environment with room temperature (20C ~ 30C) and humidity less than 85% RH, using a stable AC 220V power supply. The testers compact stainless steel construction makes it suitable for laboratory benches and production floors.
Q: What is the typical process for conducting a leak test on a cosmetic package?
A: Operators load 1 to 3 specimens into the sealing fixture, select the testing parameters via the touch panel, and start the cycle. The system automatically pressurizes the specimens, monitors for leaks, and displays results on the digital LCD. Audible and visual alarms alert users to any failed samples, and results are stored in the internal memory for traceability.
Q: How does this equipment benefit quality assurance for cosmetic products?
A: By enabling rapid, non-destructive, and highly accurate leak testing, the equipment helps manufacturers ensure the integrity of cosmetic packaging. It reduces product loss, increases customer safety, supports regulatory compliance, and streamlines quality control processes, providing long-term cost and reputational advantages.