Call Us
Send Inquiry    Call Me Free
Testing Aluminum plastic composite film Moisture Barrier for Protecting Pharmaceuticals

Testing Aluminum plastic composite film Moisture Barrier for Protecting Pharmaceuticals

50000 USD ($)/Set

Product Details:

  • Power Supply AC 220V, 50Hz
  • Response Time 5 s
  • Application Pharmaceutical packaging film moisture barrier testing
  • Measuring Range 0.01~10 g/m24h
  • Accuracy 0.01 g/m24h
  • Operating Voltage 220V AC
  • Test Range 0.05-6.0 g/m24h (water vapor)
  • Click to View more
X

Testing Aluminum plastic composite film Moisture Barrier for Protecting Pharmaceuticals Price And Quantity

  • 1 Set
  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set

Testing Aluminum plastic composite film Moisture Barrier for Protecting Pharmaceuticals Product Specifications

  • Pharmaceutical packaging film moisture barrier testing
  • 0.01~10 g/m24h
  • 5 s
  • Approx. 60 kg
  • AC 220V, 50Hz
  • 0.01 g/m24h
  • 220V AC
  • Up to 20 tests/day
  • 50-1000 mm
  • 10~50C
  • 1-3
  • Semi-automatic
  • 110 mm x 110 mm
  • 0.001 g/m24h
  • 0.05-6.0 g/m24h (water vapor)
  • 50-300 mm
  • Moisture Barrier Tester
  • Digital LCD
  • RS232, USB
  • Automatic data calculation, microcomputer controlled, data printout
  • 450 mm
  • 10%~90% RH
  • Tabletop/Laboratory
  • 10-500 mm/min (adjustable)
  • DN15
  • 0.6 MPa
  • Microcomputer control
  • Pharmaceutical humidity barrier evaluation
  • 50 Hz

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Brand new rainbow bridge structural test cell and 360 air circulation constant temperature technology ensure better temperature stability.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • The test cell is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.

High Efficiency 6 Test Cells

  • Independent six sets of 50cm2 standard area test cells, which is three times the traditional oxygen transmission rate test instrument.
  • Six samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 6.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • Intelligent test cell hood which opens and closes automatically with sound and light alert.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Space Saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving laboratory space.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C406H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.02 200
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.02 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.02 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.02 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.15
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%, 100%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 6 test chambers
Specimen Size 4.6 x 4.6i1411.7cm11.7cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



High-Precision Pharmaceutical Moisture Testing

This equipment provides advanced, accurate moisture barrier testing specifically designed for pharmaceutical packaging. With a wide measuring range, quick response time (5 s), automatic data management, and user-friendly operation, it supports rigorous quality assurance standards for pharmaceutical manufacturers and packaging suppliers alike.


Engineered for Performance and Reliability

Constructed with a corrosion-resistant stainless steel chamber and digital LCD interface, this tester is built for demanding laboratory settings. The automation features, combined with auto calibration and robust data storage (up to 200 results), guarantee precise, consistent outcomes over thousands of test cycles.

FAQ's of Testing Aluminum plastic composite film Moisture Barrier for Protecting Pharmaceuticals:


Q: How does the Moisture Barrier Tester evaluate pharmaceutical packaging films?

A: The tester uses the Coulometric sensor method to accurately measure the water vapor transmission rate through aluminum-plastic composite films, providing sensitive and reliable results crucial for pharmaceutical applications.

Q: What materials can be tested with this equipment?

A: It is suitable for a variety of film types, including aluminum blisters, composite films, and laminate foils typically used in pharmaceutical packaging, ensuring adaptable and comprehensive moisture barrier assessment.

Q: When is preconditioning required before testing?

A: Preconditioning the specimen typically takes 30 to 120 minutes prior to testing, ensuring standardized conditions for consistent and accurate moisture barrier results.

Q: Where should the tester be installed for optimal performance?

A: The equipment should be set up in a dust-free, ventilated, and dry laboratory environment to maintain measurement accuracy and prevent contamination during sensitive pharmaceutical barrier evaluations.

Q: What is the process for calibrating the device?

A: Calibration is performed automatically using film standards, which guarantees reliable results and minimizes operator intervention for routine maintenance.

Q: How is data managed and accessed after testing?

A: Test results are digitally stored with a capacity of up to 200 records, and can be retrieved, printed, or exported via RS232 or USB interfaces for analysis and quality documentation.

Q: What are the main benefits of using this tester for humidity barrier evaluation?

A: This tester delivers high sensitivity, repeatable accuracy, automated calculation, and robust data storage, making it invaluable for pharmaceutical manufacturers seeking rigorous quality control in packaging humidity protection.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.