Product Description
Featuresnote1
Batch Testing
- Equipped with fully-automatic gravity fed sample feeder, which is Labthinks latest scientific and technological achievement that can facilitate continuous testing of 20 to 120 samples.
- A & B dual-channel design can test samples of two different specifications simultaneously.
- The target vacuum degree can be set by the operator to meet testing requirements of different samples.
- Dual methods of vacuum decay and pressure decay provide the flexibility to accommodate various types of package samples.
Precise Data
- Advanced pressure detection technology, using world renowned components for data stability which is not affected by ambient environment.
- Advanced microflow automatic flow control technology that can accurately simulate different sizes of leakage holes without manual adjustment.
- Both the differential pressure transducer and flow meter are traceable to NIST.
- The system can achieve a higher test repeatability of 1um.
Intelligent Control
- 15.6" embedded touch tablet computer with Windows OS.
- New longitudinal interface layout, and easy to use graphic user interface.
- Automatic alarm, automatic capture, automatic collection of unqualified samples.
- The pressure curve is displayed in real time, and the test results are counted automatically.
- Leakage rates are calculated automatically.
- The system is equipped with various sensors as intelligent reminders for safer operation and control.
- Universal printer can be connected for test results output.
- The system features embedded with USB and network ports to facilitate the external access and data transmission of the system, which can be upgraded remotely
Security Compliance
- Verified by compensation and calibration methods.
- The leak tester meets GMP requirements for data traceability and meets the needs of the pharmaceutical industry.
- User operation permission is managed at multiple levels, and the permission content can be configured on demand.
- Electronic signature is designed according to the standard requirements of 21 CFR Part11.
Test Principle
The sample is placed in the sample feeder and automatically delivered into the test cell. The leak rate and other results can be calculated and obtained by analyzing pressure changes measured by the sensor.
Reference Standards
ASTM F2338, YY-T 0681.18, and USP<1207>
Applications
| Basic Applications |
Vials |
Various vial sealing test. |
| Extended Applications |
Ampoule |
Various ampoule bottle sealing tests. |
| Cartridge Bottles |
Various cartridge bottle sealing tests. |
| Injection bottles |
Various injection bottles sealing test. |
Technical Parameters
Table 1: Test Parameters Note2
| ParameterModel |
C690H |
| Testing Range |
um(Reference aperture size USP1207) |
3i8igreat leakage |
| Detection Lower Limit |
um |
3 |
| Resolution |
um |
0.1 |
| Repeatability |
um |
1 |
| Pressure Range |
kPa |
-100i0ii14100 |
| Extended Functions |
21 CFR Part11 |
Optional |
| GMP computer system requirements |
Optional |
Table 2: Technical Specifications
| Testing Cell |
1 set for A group and 1 set for B group |
| Sample Feeder |
1 set for A group and 1 set for B group |
| Sample Size |
I45 mm80mmNote3 |
| Sample Quantity |
20120 pieces |
| Gas Specifications |
Compressed Air (Gas source is provided by the user) |
| Gas Source Pressure |
40.6 PSI / 500 kPa |
| Port Size |
I6 mm Polyurethane tube |
| Dimensions |
33.4 H x 19.6 W x 28.7 D (85cm 50cm 73cm) |
| Power |
120VAC10% 60Hz / 220VAC10% 50Hzi14select one from the twoi14 |
| Net weight |
209Lbs (95kg) |
Product Configuration
| Standard Configuration |
Mainframe, embedded tablet computer, software, flow meter, European vacuum pump, I6 mm polyurethane tube |
| Customization |
Test cell and sample feeder of group A, test cell and sample feeder of group B, negative standard reference sample and positive standard reference sample designed according to sample specifications |
| Optional Parts |
GMP computer system requirements, 21 CFR Part11, air compressor, IQ/OQ/PQ documents |
Note 1: The described product characteristics are subject to the specific annotation of the "Technical Parameters" table.
Note 2: The parameters in the table are measured in the Labthink laboratory by professional operators according to the requirements and conditions of the relevant laboratory environmental standards.
Note 3: Group C test cell can be customized for samples beyond the "Sample Size", but the lower detection limit and test range will change according to the sample size, and the actual delivery shall prevail.
Advanced Leak Detection for Electronics PackagingThis tester is specifically designed for nondestructive packaging integrity testing in electronics manufacturing. It supports a wide variety of packaging materials, delivers precise results within 30 seconds per cycle, and is suitable for ESD trays, tapes, reels, and more. Its advanced pressure sensing and programmable vacuum system ensure accurate leak detection for enhanced quality control.
User-Friendly Operation and Data ManagementEquipped with a touch key operation panel and LCD digital display, users can initiate tests, view results, and configure settings with ease. Data logging is simplified through a USB port, making record-keeping and traceability straightforward for quality assurance teams.
Robust Design and Flexible CalibrationThe tester features a durable stainless steel shell and supports both automatic and manual calibration for ongoing accuracy. It operates in environments ranging from 10C to 40C and humidity up to 85%RH, making it versatile for different manufacturing settings.
FAQ's of Nondestructive Packaging Integrity Testing in Electronics Manufacturing:
Q: How does this leak tester perform nondestructive integrity testing on electronic packaging?
A: The tester uses dry compressed air and a high-sensitivity pressure sensor to evaluate packaging for leaks or seal defects. It operates without damaging the tested specimens, ensuring their integrity remains intact during and after the testing process.
Q: What types of packaging materials and specimen sizes can the device accommodate?
A: This instrument is suitable for ESD trays, chip trays, tape & reel, and various plastic packaging used for electronic components. It can test packaging specimens up to 120 mm in width and up to five pieces per test cycle.
Q: When should I consider using this tester in my manufacturing process?
A: This tester is ideal during final or in-process quality control checks to verify seam and seal integrity before shipment or assembly. Its rapid cycle and automated alarms help prevent defective products from progressing further in your production or supply chain.
Q: Where can the data from test results be stored or reviewed?
A: Test data can be easily logged and exported via the USB port for digital record-keeping, analysis, and compliance documentation. The LCD display also provides real-time visual feedback on test results.
Q: What is the typical process for running a test cycle on this equipment?
A: To begin testing, place your specimen on the 125 mm diameter pedestal, adjust the vacuum settings if needed, and use the touch key panel to start the cycle. After approximately 30 seconds, the device will display results, trigger an audio-visual alarm if a leak is detected, and log the data automatically.
Q: What are the main benefits of using this nondestructive packaging integrity tester?
A: Key benefits include rapid and accurate leak detection, nondestructive testing method, data traceability, compliance with CE and ISO 9001, easy calibration, and simple operation. This optimizes quality control and reduces the risk of packaging failures in electronic components.
Q: How is the tester maintained and calibrated for accuracy?
A: The device supports both automatic and manual calibration options, ensuring ongoing precision. Periodic calibration, as outlined in the user manual, is recommended to maintain best measurement accuracy over time.