Product Details:

  • Humidity 10% to 90% RH (non-condensing)
  • Operating Voltage 220V 10% AC
  • Power Supply AC 220V 10%, 50Hz
  • Features High sensitivity sensor, automatic temperature/humidity control, data logging, printer output
  • Frequency 50 Hz
  • Test Range 0.01-50 g/m/day (Moisture), 0.01-1000 cc/m/day (O)
  • Port Size IN/OUT 6 mm (standard) pipe connector
  • Click to View more
X

Testing Oxygen and Moisture Barriers in Pharmaceutical Packaging Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set

Testing Oxygen and Moisture Barriers in Pharmaceutical Packaging Product Specifications

  • Bench-top
  • 0.001 g/mday, 0.001 cc/mday
  • Automatic
  • Approximately 55 kg
  • <10 seconds
  • 100 mm x 100 mm (standard)
  • 15C to 40C
  • 1 to 3 (simultaneously)
  • Oxygen & Moisture Transmission Rate Tester
  • USB, RS232, Ethernet
  • Wide dynamic range, see test range
  • Testing oxygen and moisture barrier properties in pharma packaging
  • 5 to 50 mm/min (adjustable)
  • Max 250 mm
  • Color LCD touch display
  • 10% to 90% RH (non-condensing)
  • 220V 10% AC
  • AC 220V 10%, 50Hz
  • 0.01-50 g/m/day (Moisture), 0.01-1000 cc/m/day (O)
  • 50 Hz
  • High sensitivity sensor, automatic temperature/humidity control, data logging, printer output
  • IN/OUT 6 mm (standard) pipe connector
  • 0.01 g/mday, 0.01 cc/mday
  • Pharmaceutical packaging materials barrier testing
  • High throughput, suitable for routine QC
  • Up to 300 mm
  • 0.1 to 0.6 MPa
  • 350 mm (with cover open)
  • Microcomputer controlled, touch screen interface

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Brand new rainbow bridge structural test cell and 360 air circulation constant temperature technology ensure better temperature stability.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • The test cell is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.

High Efficiency 6 Test Cells

  • Independent six sets of 50cm2 standard area test cells, which is three times the traditional oxygen transmission rate test instrument.
  • Six samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 6.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • Intelligent test cell hood which opens and closes automatically with sound and light alert.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Space Saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving laboratory space.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C406H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.02 200
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.02 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.02 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.02 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.15
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%, 100%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 6 test chambers
Specimen Size 4.6 x 4.6i1411.7cm11.7cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Advanced Barrier Testing for Pharmaceutical Packaging

Ensure the integrity and compliance of your pharmaceutical packaging with a high-performance Oxygen & Moisture Transmission Rate Tester. This bench-top system offers automatic multi-point calibration, rapid response, high accuracy, and advanced data management. Its wide dynamic range, adjustable test speed, and user-friendly interface make it a perfect solution for R&D, laboratory, and industrial quality control environments, supporting both routine and challenging testing needs.


Compliant with International Standards

This tester meets the strict requirements of ASTM F1249, ASTM D3985, ISO 15106, and ISO 11607. Compliance with these standards guarantees that your pharmaceutical packaging materials are assessed using recognized and globally accepted methods, ensuring safety, efficacy, and regulatory acceptance.


Efficient, Accurate, and Flexible Operation

With the ability to test 1 to 3 specimens simultaneously, high throughput capacity, and rapid test speeds from 5 to 50 mm/min, the system delivers efficient performance. The automatic temperature and humidity control boosts result consistency, while built-in safety features ensure trouble-free use during routine operations.

FAQ's of Testing Oxygen and Moisture Barriers in Pharmaceutical Packaging:


Q: How does the Oxygen & Moisture Transmission Rate Tester work for pharmaceutical packaging?

A: The tester measures the rate at which oxygen and moisture permeate through packaging materials using electrochemical (O2) and infrared (moisture) sensors. It maintains controlled test environments and records data automatically, ensuring results comply with ASTM F1249, ASTM D3985, ISO 15106, and ISO 11607 standards.

Q: What compliance standards are supported by this equipment?

A: The instrument supports industry-recognized compliance requirements including ASTM F1249, ASTM D3985, ISO 15106, and ISO 11607, making it suitable for regulatory submissions and quality control in pharmaceutical packaging assessment.

Q: When and where should this tester be used for optimal results?

A: It is best used in laboratory, R&D, and industrial quality control settings whenever accurate, reliable measurement of packaging barrier properties is required. It is suitable for ongoing quality monitoring, new package development, and investigation of barrier material performance.

Q: What is the process for conducting a barrier test?

A: Operators prepare specimens (100 mm x 100 mm), place them in the test chamber, and configure the parameters via the touch screen. The system performs fully automated calibration, controls the environment, and analyzes permeability, storing results internally or exporting via USB, RS232, or Ethernet.

Q: How is user safety ensured during operation?

A: Safety features include a leak detector, over-temperature protection, and automatic shutdown functions. These safeguards protect both the operator and the equipment while maintaining testing integrity.

Q: What are the main practical benefits of using this tester?

A: It offers highly accurate, sensitive, and reproducible measurement of oxygen and moisture barrier properties-critical for preserving pharmaceutical product efficacy. Automation, high throughput, easy data logging, and robust service support further boost productivity and compliance.

Q: Does the tester accommodate different packaging materials and thicknesses?

A: Yes, the wide dynamic test range, adjustable test speed, accommodating specimen sizes, and capacity for multiple simultaneous samples make it suitable for assessing a variety of pharmaceutical packaging materials and formats.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.