Call Us
Send Inquiry
Milk Powder Packaging Materials Oxygen and Water Vapor Transmission Rates test

Milk Powder Packaging Materials Oxygen and Water Vapor Transmission Rates test

50000 USD ($)/Set

Product Details:

  • Port Size Customized as per requirement
  • Application Milk powder packaging barrier property evaluation
  • Mounting Type Desktop
  • Specimen Size 100 mm x 100 mm
  • Resolution 0.01 cc/md (Oxygen) / 0.01 g/md (Water Vapor)
  • Humidity 20%~90% RH (adjustable)
  • Display Type Digital LCD
  • Click to View more
X

Milk Powder Packaging Materials Oxygen and Water Vapor Transmission Rates test Price And Quantity

  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set

Milk Powder Packaging Materials Oxygen and Water Vapor Transmission Rates test Product Specifications

  • Digital LCD
  • 350 mm
  • Oxygen and water vapor transmission rate
  • Microcomputer controlled
  • Max 300 mm
  • 15C~50C (programmable)
  • 0.6 MPa
  • Customized as per requirement
  • Milk powder packaging barrier property evaluation
  • Desktop
  • 100 mm x 100 mm
  • Multiple samples
  • 0.01 cc/md (Oxygen) / 0.01 g/md (Water Vapor)
  • 20%~90% RH (adjustable)
  • AC 220V, 50 Hz
  • 1% of reading
  • Automatic
  • Automatic test, data storage, alarm functions
  • <10 seconds
  • 50 Hz
  • 220V AC
  • 0.05~10,000 cc/m24h for OTR / 0.05~10,000 g/m24h for WVTR
  • 0.1~10 cm/min adjustable
  • Packaging material testing
  • 3 simultaneously
  • Approx. 40 kg
  • RS232, USB
  • Bench-top gas permeability tester
  • 10 mm~50 mm

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

High Efficiency Three-cell

  • Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
  • Three samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C403H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.01 200
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.01 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.005 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.005 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.05
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 test chambers
Specimen Size 4.4 x 4.4i1411.2cm11.2cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Advanced Packaging Barrier Assessment

Engineered for milk powder packaging, this instrument delivers precise measurement of oxygen and water vapor transmission rates, crucial for maintaining product freshness. Its automatic test functions and digital LCD display simplify the evaluation process for packaging materials, aiding research, quality control, and manufacturing teams in ensuring compliance with global standards.


Robust Construction and Flexible Operation

With a stainless steel chamber and desktop mounting, the tester offers durability and stability. It supports simultaneous multi-sample testing, programmable temperature and humidity, and adjustable test speeds. Compact and lightweight at approx. 40 kg, the equipment is easily integrated into laboratory environments, supported by a quiet operation below 55 dB.

FAQ's of Milk Powder Packaging Materials Oxygen and Water Vapor Transmission Rates test:


Q: How does this tester measure oxygen and water vapor transmission rates in milk powder packaging materials?

A: The instrument employs dedicated oxygen and water vapor permeability test modes, using high-purity gases that pass through samples mounted in a stainless steel chamber. It measures the rates electronically and displays results on a digital LCD, ensuring accurate evaluation of the packaging's barrier properties.

Q: What standards does the device comply with for packaging material testing?

A: This tester complies with internationally recognized standards, including ASTM D3985, ISO 15106, and GB/T 1038, ensuring reliable and comparable results for oxygen and water vapor transmission rates in packaging materials.

Q: When should calibration be performed on the tester, and what methods are available?

A: Calibration should be conducted periodically or whenever accuracy needs verification. The unit offers both automatic and manual calibration options, allowing users flexibility and confidence in maintaining measurement precision.

Q: Where is the best location to operate the packaging material tester?

A: For optimal results, the tester should be installed in a low vibration, dust-free environment to ensure stability and data accuracy. A standard laboratory setting meeting these conditions is most suitable.

Q: What is the process for running tests on packaging specimens?

A: Specimens, up to three at a time with sizes of 100 mm x 100 mm, are placed into the chamber. The tester is programmed for the desired temperature, humidity, and test speed. After initiation via the touchscreen interface, results are recorded and can be exported via USB or printer connection.

Q: How does using this tester benefit milk powder packaging manufacturers?

A: Manufacturers gain reliable data on the barrier properties of their packaging, helping improve shelf life and maintain product quality. Automated testing, high accuracy, and compliance with international standards streamline quality assurance and support regulatory certifications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.