Product Description
High Precision
- Patented test chamber and test dishes with advanced fluid dynamics and thermodynamic designs.
- Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
- Precise and scientific regulation and calculation of testing conditions.
High Efficiency
- 12 test stations
- Supports test modes of desiccant method and water method
Labor Saving
- Automatic humidity and flow rate controlling.
- Desiccator requires no replacement of inner core.
- High-efficiency water vapor generator.
Simplified Operation
- 12 touch-screen pad powered by WindowsTM 10 operating system
- Fast automatic testing process
- Optional DataShieldTM software and accessories for automatic data management
Product Features
New Generation Test Chamber and Test Dishes
Patented test chamber and test dishes with advanced hydrodynamic and thermodynamic designs ensure the uniform flow rate over the specimen surface, stable temperature and humidity, creating a uniform and stable testing environment. As a result, the test duration is shortened and the test results will be more accurate.
Excellent Testing Abilities of High and Low Barrier Materials
The testing conditions will be regulated precisely in real time, which ensures the high testing accuracy and repeatability of high and low barrier materials.
Automatic Controlling of Temperature, Humidity and Air Velocity
Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
Air velocity is monitored and regulated in real time.
High-efficiency and mist-free automatic humidity regulator meets the requirements for long-term continuous tests.
It is unnecessary to replace the inner core of the desiccator, which can continuously work for 20,000 hours.
Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system facilitates centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.
User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.
Test Principle
The test specimen is mounted in the test dish which contains water or desiccant inside. The test dish is placed in the test chamber with stable temperature, humidity and air flow. The water vapor permeates through the specimen and into the dry side. By measuring the weight changes of the test dish periodically, water vapor transmission rate and other parameters can be obtained.
Test Standards
ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, GB/T 1037, GB/T 16928, YBB 00092003-2015
Applications
| Basic Applications |
- Films
Plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminum coated films, aluminum foil composite films, glass fiber aluminum foil paper composite films and many other film materials
|
- Sheeting
PP, PVC and PVDC sheeting, metal foils, rubber pads and other sheeting materials
|
- Paper and Paper Board
Aluminum coated paper for cigarette, paper aluminum plastic composite film and other paper and paperboards
|
- Textiles and Nonwovens
Textiles and nonwoven fabrics
|
| Extended Applications |
- Construction Materials
Geotextiles, felt, roofing and building materials, vapor barrier membranes, etc.
|
- Aseptic Wound Protection Films and Medical Plasters
Aseptic wound protecting films, medical plasters and protective clothing materials
|
Technical Specifications
Table 1: Test Parameters Note1
| Parameter |
Model C360H |
| Testing Efficiency |
0.01g/(m2day) 0.5g/(m2day) |
>24 hours |
| 0.0006g/(100in2day) 0.0323g/(100in2day) |
| 0.5 g/(m2day)5 g/(m2day) |
12 24 hours |
| 0.0323g/(100in2day) 0.3225g/(100in2day) |
| > 5 g/(m2day) |
12 hours |
| > 0.3225 g/(100in2day) |
| Max. Test Range |
Water Method |
10000/ni141-12i14g/(m2day) |
| 645/ni141-12i14g/(100in2day) |
| Desiccant Method |
1200g/(m2day) per piece |
| 77g/(100in2day) per piece |
| Test Station |
|
12 |
| Test Temperature |
C |
20 55 0.2 |
| Test Humidity |
RH |
10% 90% 1% |
| Additional Functions |
DataShieldTM Note2 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Specimen Size |
I74mm |
| Specimen Thickness |
3mm |
| Test Method |
Desiccant Method / Water Method |
| Standard Test Area |
33cm2 |
| Carrier Gas |
Compressed Air |
| Drying of Carrier Gas |
Long Service-life Desiccator (unnecessary to replace inner core) |
| Humidifying of Carrier Gas |
High-efficiency mist-free humidity generator |
| Carrier Gas Pressure |
0.6 MPa |
| Port Size |
I6mm PU Tubing |
Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.
High-Throughput, Precise WVTR TestingEngineered for textile laboratories, the WVTR Tester offers reliable measurement of water vapor transmission across woven and nonwoven materials. Its automated operation supports up to six samples at once with superior accuracy and adjustable speed, helping users achieve rapid, consistent results. The system's high-resolution sensor and digital monitoring combine for precise control throughout each analysis cycle.
Easy Operation and Comprehensive Data ManagementFeaturing a 7-inch color LCD touchscreen and intuitive software (with user license included), the tester streamlines the entire process: from quick sample setup, through real-time monitoring, to exportable PDF or CSV reports. Internal memory ensures secure data storage, while versatile connectivity (USB and RS232) eases data transfer. Users benefit from automated data processing and straightforward calibration options.
Compliant, Adaptable, and Laboratory-ReadyThe tester is fully compliant with major standards (ASTM E96, ISO 2528, GB/T 12704) and supports various operating conditions (temperature: 15-35C, humidity 85% RH). Its robust benchtop design and high performance make it ideal for routine or research use, adapting seamlessly to evolving laboratory needs in woven, nonwoven, and allied material testing.
FAQ's of WVTR Tester for woven and nonwoven testing:
Q: How is the WVTR Tester used for analyzing woven and nonwoven fabrics?
A: The WVTR Tester is designed to evaluate water vapor transmission rates by allowing users to quickly prepare samples (less than 5 minutes per specimen), load them into holders, and operate the automated test via its touchscreen interface. It measures permeability precisely across specimen sizes up to 74 mm, delivering accurate, repeatable results meeting textile industry standards.
Q: What testing standards does the WVTR Tester comply with?
A: This equipment is fully compliant with ASTM E96, ISO 2528, and GB/T 12704, ensuring that results obtained are globally recognized and suitable for regulatory, research, or quality control purposes in textile and materials testing.
Q: When should calibration of the WVTR Tester be performed and how is it done?
A: Calibration can be conducted either automatically or manually at regular intervals or before critical analyses for optimal accuracy. The system provides step-by-step calibration guidance, ensuring reliable results with high-precision electronic balance sensors.
Q: Where is the best environment for operating the WVTR Tester?
A: The device operates most efficiently in laboratory spaces with temperatures between 15-35C and humidity levels not exceeding 85% RH. Controlled ambient conditions help maintain measurement accuracy and prolong equipment lifespan.
Q: What is the process for exporting test results from the WVTR Tester?
A: Once a test is complete, results are automatically processed and can be exported as PDF or CSV files via USB or RS232 interfaces. This ensures seamless integration with laboratory information systems and facilitates easy data sharing or archiving.
Q: What are the key benefits of using the WVTR Tester in textile analysis?
A: Users benefit from high-throughput capability (up to six simultaneous tests), automation, fast response time (2 s), precise measurements, and versatile data handling-making it ideal for efficient, reliable assessment of material permeability in textile research and quality control.