Product Description
High Precision
- Patented test chamber and test dishes with advanced fluid dynamics and thermodynamic designs.
- Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
- Precise and scientific regulation and calculation of testing conditions.
High Efficiency
- 12 test stations
- Supports test modes of desiccant method and water method
Labor Saving
- Automatic humidity and flow rate controlling.
- Desiccator requires no replacement of inner core.
- High-efficiency water vapor generator.
Simplified Operation
- 12 touch-screen pad powered by WindowsTM 10 operating system
- Fast automatic testing process
- Optional DataShieldTM software and accessories for automatic data management
Product Features
New Generation Test Chamber and Test Dishes
Patented test chamber and test dishes with advanced hydrodynamic and thermodynamic designs ensure the uniform flow rate over the specimen surface, stable temperature and humidity, creating a uniform and stable testing environment. As a result, the test duration is shortened and the test results will be more accurate.
Excellent Testing Abilities of High and Low Barrier Materials
The testing conditions will be regulated precisely in real time, which ensures the high testing accuracy and repeatability of high and low barrier materials.
Automatic Controlling of Temperature, Humidity and Air Velocity
Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
Air velocity is monitored and regulated in real time.
High-efficiency and mist-free automatic humidity regulator meets the requirements for long-term continuous tests.
It is unnecessary to replace the inner core of the desiccator, which can continuously work for 20,000 hours.
Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system facilitates centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.
User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.
Test Principle
The test specimen is mounted in the test dish which contains water or desiccant inside. The test dish is placed in the test chamber with stable temperature, humidity and air flow. The water vapor permeates through the specimen and into the dry side. By measuring the weight changes of the test dish periodically, water vapor transmission rate and other parameters can be obtained.
Test Standards
ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, GB/T 1037, GB/T 16928, YBB 00092003-2015
Applications
| Basic Applications |
- Films
Plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminum coated films, aluminum foil composite films, glass fiber aluminum foil paper composite films and many other film materials
|
- Sheeting
PP, PVC and PVDC sheeting, metal foils, rubber pads and other sheeting materials
|
- Paper and Paper Board
Aluminum coated paper for cigarette, paper aluminum plastic composite film and other paper and paperboards
|
- Textiles and Nonwovens
Textiles and nonwoven fabrics
|
| Extended Applications |
- Construction Materials
Geotextiles, felt, roofing and building materials, vapor barrier membranes, etc.
|
- Aseptic Wound Protection Films and Medical Plasters
Aseptic wound protecting films, medical plasters and protective clothing materials
|
Technical Specifications
Table 1: Test Parameters Note1
| Parameter |
Model C360H |
| Testing Efficiency |
0.01g/(m2day) 0.5g/(m2day) |
>24 hours |
| 0.0006g/(100in2day) 0.0323g/(100in2day) |
| 0.5 g/(m2day)5 g/(m2day) |
12 24 hours |
| 0.0323g/(100in2day) 0.3225g/(100in2day) |
| > 5 g/(m2day) |
12 hours |
| > 0.3225 g/(100in2day) |
| Max. Test Range |
Water Method |
10000/n1-12g/(m2day) |
| 645/n1-12g/(100in2day) |
| Desiccant Method |
1200g/(m2day) per piece |
| 77g/(100in2day) per piece |
| Test Station |
|
12 |
| Test Temperature |
C |
20 55 0.2 |
| Test Humidity |
RH |
10% 90% 1% |
| Additional Functions |
DataShieldTM Note2 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Specimen Size |
74mm |
| Specimen Thickness |
3mm |
| Test Method |
Desiccant Method / Water Method |
| Standard Test Area |
33cm2 |
| Carrier Gas |
Compressed Air |
| Drying of Carrier Gas |
Long Service-life Desiccator (unnecessary to replace inner core) |
| Humidifying of Carrier Gas |
High-efficiency mist-free humidity generator |
| Carrier Gas Pressure |
0.6 MPa |
| Port Size |
6mm PU Tubing |
Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.
Advanced Testing PrincipleThe WVTR Testing Machine uses a gravimetric method, incorporating three test cups within a 30-liter chamber to assess water vapor transmission. This principle ensures high precision and is widely recognized under global standards for medical device testing, particularly for hydrogel dressings.
Flexible Laboratory OperationDesigned with user adaptability in mind, the machine features adjustable temperature, humidity, and test stroke settings. Its benchtop configuration, LCD display, automatic calibration, and easy data export options (USB and printer) provide flexibility and efficiency for various testing scenarios in professional laboratories.
Safety and Compliance AssuredCompliance with YY/T 0471, ISO 2528, and ASTM E96 ensures trust in data accuracy and reliability. Overload protection, automatic alarming, and a durable build (45 kg) guarantee operator safety while supporting continuous, rigorous use in demanding environments.
FAQs of Testing Medical Hydrogel Dressings WVTR:
Q: How does the WVTR Testing Machine measure water vapor transmission in hydrogel dressings?
A: The machine uses a gravimetric method with three test cups in a controlled environment chamber to determine the water vapor transmission rate (WVTR) across medical hydrogel dressings. Automated calibration with standard weights and precise PID microcomputer control ensure accurate, repeatable measurements.
Q: What types of results can be exported from the machine, and how is data managed?
A: Test results can be exported through USB and RS232 interfaces or printed directly from the device. The built-in storage holds up to 10,000 test results, making long-term data management efficient and straightforward.
Q: When is it necessary to calibrate the WVTR Testing Machine, and how is this achieved?
A: Calibration is recommended regularlyespecially before critical testing cycles. The system supports automatic calibration using standard weights, maintaining high measurement accuracy with minimal user intervention.
Q: Where can the machine be installed, and what are the space requirements?
A: This benchtop device is best suited for laboratory environments with stable power supply (220V 10%, 50Hz) and minimal electromagnetic interference. It measures approximately 610420410 mm and weighs 45 kg, requiring a sturdy lab bench for optimal placement.
Q: What is the process for conducting a standard WVTR test on medical hydrogel dressings?
A: Users place 16 hydrogel specimens (each 74 mm x 74 mm) into the test cups, set desired parameters (temperature, humidity, speed), and initiate the automatic test sequence. The machine records changes in mass, calculates WVTR, and displays results in real time.
Q: What benefits does the machine provide for manufacturers and medical researchers?
A: The system offers high precision, consistent compliance with global standards, and customizable test conditions. Users benefit from automated operation, comprehensive safety features, robust data management, and time-saving performance ideal for research, product development, or quality assurance.
Q: Can I operate the machine in different languages?
A: Yes, the WVTR Testing Machine supports both Chinese and English interfaces, making operation accessible for international teams and users in diverse laboratory settings.