Product Details:

  • Number of Specimens 1-3 samples simultaneously
  • Test Range OTR: 0.01-2000 cc/m24hatm, WVTR: 0.01-1000 g/m24h
  • Automation Grade Automatic
  • Features High precision sensor, automatic temperature/humidity control
  • Frequency 50Hz
  • Port Size 6 mm gas port
  • Display Type LCD Touch Screen
  • Click to View more
X

Packaging Materials OTR and WVTR Measuring Instrument for Extending Fresh Food Shelf Life Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set
  • ±2% RH
  • Data export and analysis capability
  • One-key intelligent operation
  • <60 dB(A)
  • Electrochemical sensor for OTR, Infrared sensor for WVTR
  • Yes, optional
  • Stainless steel
  • ±0.1°C
  • OTR (Oxygen Transmission Rate), WVTR (Water Vapor Transmission Rate)
  • Automatic and manual available
  • Pure oxygen or dry air

Packaging Materials OTR and WVTR Measuring Instrument for Extending Fresh Food Shelf Life Product Specifications

  • Tabletop
  • 0.01 cc/m24hatm (OTR), 0.01 g/m24h (WVTR)
  • OTR & WVTR Measuring Instrument
  • 220V AC
  • High sensitivity detection
  • USB, RS232
  • AC 220V, 50Hz
  • 420 mm
  • 0.1-10 mm/min adjustable
  • Relative humidity 50%-90% RH
  • 0.001 cc/m24hatm
  • Measuring packaging film oxygen and water vapor transmission to extend fresh food shelf life
  • 100 mm
  • OTR: 0.01-2000 cc/m24hatm, WVTR: 0.01-1000 g/m24h
  • 1-3 samples simultaneously
  • High precision sensor, automatic temperature/humidity control
  • Automatic
  • Packaging material permeability testing
  • 6 mm gas port
  • 50Hz
  • 30 kg
  • LCD Touch Screen
  • OTR: 0.01-2000 cc/m24hatm, WVTR: 0.01-1000 g/m24h
  • 0.3-0.5 MPa
  • Room temperature to 50C adjustable
  • 30 seconds
  • Microcomputer control
  • 100 mm x 100 mm
  • 300 mm
  • ±2% RH
  • Data export and analysis capability
  • One-key intelligent operation
  • <60 dB(A)
  • Electrochemical sensor for OTR, Infrared sensor for WVTR
  • Yes, optional
  • Stainless steel
  • ±0.1°C
  • OTR (Oxygen Transmission Rate), WVTR (Water Vapor Transmission Rate)
  • Automatic and manual available
  • Pure oxygen or dry air

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Brand new rainbow bridge structural test cell and 360 air circulation constant temperature technology ensure better temperature stability.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • The test cell is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.

High Efficiency 6 Test Cells

  • Independent six sets of 50cm2 standard area test cells, which is three times the traditional oxygen transmission rate test instrument.
  • Six samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 6.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • Intelligent test cell hood which opens and closes automatically with sound and light alert.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Space Saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving laboratory space.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C406H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.02 200
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.02 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.02 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.02 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.15
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%, 100%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 6 test chambers
Specimen Size 4.6 x 4.6i1411.7cm11.7cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Precision Control for Accurate Results

Engineered with state-of-the-art temperature and humidity controls, the instrument achieves an accuracy of 0.1C and 2% RH respectively. Its microcomputer management and sensor technologies ensure each test is repeatable and reliable, allowing packaging engineers to trust the data for strategic decision-making.


Effortless Testing and Data Management

Featuring an intuitive LCD touch screen and a user-friendly one-key operation, this equipment streamlines sample measurement. Automatic temperature and humidity settings, rapid response time (30 seconds), and both USB and RS232 interfaces make data analysis and export efficient for comprehensive quality assurance.


Designed for Food Packaging Innovation

By accurately measuring both OTR and WVTR, this instrument empowers the food industry to select packaging materials that significantly extend the shelf life of fresh foods. The high-sensitivity detection and simultaneous multi-sample testing make it an indispensable tool for R&D, ensuring freshness and quality from supplier to consumer.

FAQ's of Packaging Materials OTR and WVTR Measuring Instrument for Extending Fresh Food Shelf Life:


Q: How does this instrument measure oxygen and water vapor permeability of packaging materials?

A: The instrument employs high-precision sensors-an electrochemical sensor for oxygen transmission rate (OTR) and an infrared sensor for water vapor transmission rate (WVTR)-to quantitatively assess the permeability of packaging films. Test conditions such as temperature and humidity are finely controlled for accurate results.

Q: What benefits does this instrument offer for extending the shelf life of fresh food?

A: By providing precise measurements of how much oxygen and water vapor can pass through packaging films, the instrument helps manufacturers select optimal materials that best preserve food freshness, flavor, and overall shelf life, reducing spoilage and waste.

Q: When is this device typically used during food packaging testing?

A: This equipment is used during the research and development, quality assurance, and materials selection phases. It assists in evaluating new films, comparative studies, and routine production checks to ensure consistent packaging performance.

Q: Where can this instrument be installed?

A: Its tabletop, compact design allows for installation in research labs, quality control departments, or production facilities. The stainless steel chamber ensures durability in a range of environments, while the low noise level (<60 dB) suits shared laboratory spaces.

Q: What is the testing process like with this instrument?

A: Users mount up to three specimens in the chamber, set their required test parameters through the LCD touch screen, and initiate testing with a single key. The device regulates temperature and humidity, measures OTR/WVTR, and then outputs the data for analysis or export.

Q: How does the instrument ensure accuracy and repeatability?

A: The system integrates automatic and manual calibration functions. Combined with advanced sensors, precise temperature/humidity control, and microcomputer monitoring, the device delivers repeatable, consistently accurate results within its high sensitivity range.

Q: What types of gases and environmental conditions can the instrument operate with?

A: The instrument is compatible with pure oxygen or dry air as test gases. It accommodates relative humidity levels from 50% to 90% RH and adjustable temperatures from room temperature up to 50C, meeting diverse testing requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.