Call Us
Send Inquiry
Gas Permeability Tester for Heat Patch Inner Packaging Quality Control

Gas Permeability Tester for Heat Patch Inner Packaging Quality Control

50000 USD ($)/Set

Product Details:

  • Mounting Type Benchtop
  • Operating Voltage AC 220V
  • Specimen Size Up to 120 mm 120 mm
  • Equipment Type Gas Permeability Tester
  • Response Time 5 seconds
  • Power Supply AC 220V 10%, 50Hz
  • Humidity 20% to 90% RH
  • Click to View more
X

Gas Permeability Tester for Heat Patch Inner Packaging Quality Control Price And Quantity

  • 50000 USD ($)/Set
  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set

Gas Permeability Tester for Heat Patch Inner Packaging Quality Control Product Specifications

  • 45 kg
  • 2% of reading
  • 400 mm
  • Up to 300 mm
  • Automatic
  • Maximum 200 mm
  • 50 Hz
  • 0 to 0.3 MPa adjustable
  • Standard 6 mm gas fitting
  • RS232, USB port
  • Heat Patch Inner Packaging Quality Control
  • LCD digital display
  • 0.01 cm/(m24h0.1MPa)
  • 10C to 50C
  • High precision sensors, multi-point calibration, automatic temperature and humidity compensation
  • Microcomputer automatic control
  • 0.01 to 1 mm/min adjustable
  • 1 to 3 simultaneously
  • 3 test chambers
  • Up to 120 mm 120 mm
  • AC 220V
  • Benchtop
  • 0.01 to 1000 cm/(m24h0.1MPa)
  • 0.01 to 1000 cm/(m24h0.1MPa)
  • 5 seconds
  • 20% to 90% RH
  • AC 220V 10%, 50Hz
  • Laboratory and industrial packaging testing
  • Gas Permeability Tester

Product Description

Product FeaturesNote1

Accurate Data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01i0.09cm3/ m324h0.1MPa test range.
  • Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
  • Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
  • The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
  • Labthinks unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
  • The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.

High Efficiency

  • Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Medium and low barrier materials, test time <4 hours (including vacuumize time).
  • High barrier materials, test time <4 hours (including vacuumize time).
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
  • Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Tests of hazardous gases such as H2aCH4 are applicable (Customize).

Test Principle

The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.

Standard

ISO 15105-1aISO 2556aGB/T 1038-2000aASTM D1434aJIS K7126-1aYBB 00082003

Applications

Applications
  • Films
    Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C106H
Test range cm3/m224h0.1MPa 0.01i50,000
Resolution cm3/m224h0.1MPa 0.001
Test temperature 15i50i145i60i14Optionali14
Temperature resolution 0.01
Temperature fluctuation 0.15
Test humidity %RHi14Within standard test temperature rangei14 0%i145i902%i14Customizei14
Vacuum Resolution Pa 0.01
Vacuum Accuracy Pa 0.2%i141%-100% of Full Scalei14
Vacuum Degree of Test Chamber Pa 10
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.6i1411.7cm11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 38.48cm2
Test Gas O2aN2aCO2 etc.i14Outside of supply scopei14
Test Pressure 10 kPa210 kPai14Can be set betweeni14
Pressure Fluctuation 0.2 kPa
Gas Pressure 79.7 PSI / 550 kPa
Port Size I6 mm PU tubing
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz/220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, I6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas compressor port of the instrument is I6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Advanced Differential Pressure Method

This tester employs the differential pressure method to accurately measure the gas permeability of packaging materials for heat patches. Automatic digital calibration ensures consistent precision across every test. Real-time monitoring and rapid response time streamline the testing process, making it ideal for both routine laboratory assessments and industrial quality control applications.


Comprehensive Safety and Data Management

The design prioritizes operator safety with overpressure protection and an emergency stop function. Data management is facilitated by storage for up to 1000 records and advanced analysis via Windows-based software. The integrated cutter aids sample preparation, while the LCD digital display and automated controls enhance usability and traceability during testing.


Versatile Material and Specimen Handling

Compatible with various materials including plastic films, composite packaging, and foils, the tester accommodates up to three specimens at a time with a maximum size of 120 120 mm. Adjustable test speed, stroke, and width allow flexibility for different sample types, supporting diverse industry needs in packaging quality assurance.

FAQ's of Gas Permeability Tester for Heat Patch Inner Packaging Quality Control:


Q: How does the Gas Permeability Tester measure the permeability of heat patch packaging?

A: The tester utilizes the differential pressure method, which measures the rate of gas transfer through packaging materials. Specimens are placed in test chambers, and the system automatically calibrates to ensure accurate and repeatable results.

Q: What types of materials can be tested with this equipment?

A: It is compatible with plastic films, composite materials, and foil packaging commonly used for heat patch inner layers, making it suitable for a wide range of laboratory and industrial packaging applications.

Q: When should I use the integrated cutter during preparation?

A: You use the integrated cutter to precisely size your specimens before loading them into the test chambers, ensuring that each sample meets the required dimensions for accurate testing.

Q: Where should the Gas Permeability Tester be installed for optimal performance?

A: For best results, install the equipment indoors in a clean, dust-free environment. Proper placement ensures stable readings and longevity of the device.

Q: What are the steps involved in the testing process?

A: Prepare the specimen using the integrated cutter, place it into one of the test chambers, set your preferred testing parameters such as speed and stroke, and start the automated process. Results are displayed digitally on the LCD and stored for analysis.

Q: How is calibration achieved and maintained?

A: Calibration is performed automatically using the machine's digital system and high-precision sensors. Multi-point calibration and temperature/humidity compensation ensure each test adheres to strict accuracy standards, reducing the need for manual adjustments.

Q: What are the advantages of using this tester for packaging quality control?

A: Benefits include high accuracy (2%), reliable safety features, fast response time (5 seconds), easy-to-use software for analysis, large data storage, and flexible specimen handling. These features enable efficient identification of packaging defects and provide comprehensive quality assurance for heat patch products.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.