Product Description
Product FeaturesNote1
Professional Test Modes to Meet Various Testing Demands
- Multiple independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, and compression test, etc. at users choice
- The instrument supports bidirectional testing modes and test speed can be adjusted freely
- Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users
Excellent Testing Mechanism & Improved Test Accuracy
- Force measuring system is supplied by top global supplier, which ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
- Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
- Global renowned brand pneumatic control system supports pneumatic specimen clamping, which avoids the specimen slipping and guarantees the accuracy of test data
High-end, Secure and Easy-to-Use Embedded Computer-controlled System
- Large size touch screen tablet for better viewing and easy operation
- Brand new software and system provide smooth and simplified operating experience
- The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
- Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
- The instrument is equipped with USB ports and Internet ports for convenient data transmission.
- Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.
Test StandardNote1
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
C610H is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:
| Basic Applications |
|
|
- Test of Tensile Strength and Elongation Rate
|
- Test of Tensile Strength at Break
|
|
|
|
|
|
|
|
|
- Tensile Strength Test at Defined Elongation
|
Extended Applications (Additional Accessories Required) |
- Puncture Test of Hypodermic Needles in Artificial Skin
|
|
- Puncture Test of Infusion Bags
|
- Puncture/Pullout Test of Flexible Rubber Closures
|
- Opening Resistance Test of Combined Covers
|
- Tear Test of ZD - Type Caps
|
- Opening Force Test of Oral Liquid Caps
|
- Puncture/Pullout Test of Oral Liquid Caps
|
- 90 Degree Pullout Test of Infusion Bag Caps
|
- Pullout Test of Infusion Bag Caps
|
- 23 Degree Pullout Test of Bottle Caps
|
- Puncture/Pullout Test of Bottle Caps or Rubber Closures
|
- 90 Degree Peel Test of Adhesive Tapes
|
- Tear Resistance Test of Adhesive Binding Books
|
- 90 Degree Peel Test of Water-soluble Plasters
|
- Tear Resistance Test of Adhesives
|
- Adhesive Strength Test (soft)
|
- Adhesive Strength Test (hard)
|
- Peel Test of Flexible Tube Caps
|
- Removal Force of Pipes and Pipe Joints
|
- Pullout Test of Cosmetic Brush Hair
|
- Pullout Test of Tooth Brush Hair
|
- Tensile Strength of Ropes at Break
|
- Opening Force Test of Jelly Cups and Yogurt Cups
|
|
|
- Pullout Test of Rubber Stoppers
|
- 45 Degree Peel Test of Bottle Membranes
|
- Tensile Strength of Sealing Bags
|
- Peel Test of Magnetic Cores
|
- 90 Degree Peel Test of Magnetic Cards
|
- Tear Resistance of Heat Sealing Films
|
- Separating Force of Protection Films
|
- Peel Test of Release Paper
|
- Tear Test Using Trouser Method
|
- Unwrapping Force of Adhesive Tapes
|
- Compressive Resistance of Plastic Bottles
|
|
|
- 135 Degree Peel Test of Plugs
|
- Peeling Grips of Floating Rollers
|
|
|
|
|
|
|
- Tensile Strength of Contact Lenses at Break
|
- Compression Resistance of Jelly Cups
|
- Compression Resistance of Package
|
- Compression Resistance of Sponge
|
|
Technical SpecificationsNote2
| Specifications |
C610H Auto Tensile Tester |
| Load Cell Capacity |
500 N (standard) 50 N, 100 N, 250 N, 1000 N (optional) |
| Accuracy |
0.5% of indicated value (2%FS100%FS) 0.01%FS (0% 2%FS) |
| Resolution |
0.001 N |
| Test Speed |
0.05 500 mm/min |
| Speed Accuracy |
0.5% of indicated value (1%100% of maximum speed) |
| Number of Specimens |
1 |
| Specimen Width |
30 mm (Standard Grip) |
| 50 mm (Optional Grip) |
| Clamping Way |
Pneumatic Specimen Clamp |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 Mpa (72.5psii101.5psi) |
| Stroke |
1000 mm |
| Instrument Dimension |
500 mm (L) 520 mm (W) 1900 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
110 kg |
Configurations
- Standard Configurations
- Instrument, Professional Software, Tablet, Pneumatic Sample Grips
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Customized Grips, Laser Printer, Air Compressor, Computer System required by GMP, DataShieldTM Note3
- Note
- 1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Advanced Digital Control SystemOperate the tensile tester through a robust microcomputer or intuitive touchscreen interface, facilitating easy navigation and precise test management. The LCD touch display ensures clear visualization of all test parameters and results, enhancing efficiency and reducing operator error.
High Precision Measurement and SafetyThe high precision strain gauge load cell provides accurate force readings, while digital elongation tracking guarantees reliable data. With emergency stop and over-travel protection, safety is prioritized during all testing stages, preventing accidents and equipment damage.
Flexible Data ManagementEasily export test data via USB or thermal printer for seamless record-keeping and analysis. Compatible with Windows-based software, the system supports comprehensive analysis and reporting requirements, ensuring streamlined workflow in diverse laboratory settings.
FAQ's of Films Tensile Strength Testers:
Q: How is elongation measured during film tensile strength testing?
A: Elongation is measured digitally with high precision throughout each test, allowing for accurate assessment of how much a film sample stretches before breaking. The data is displayed in real-time on the LCD touchscreen.
Q: What are the safety features included with the tensile strength tester?
A: The machine is equipped with emergency stop functionality, over-travel, and overload protection to prevent injuries or damage to specimens and ensure user safety during operation.
Q: When should the test speed be adjusted, and how can it be set?
A: Test speed can be set between 50 to 500 mm/min depending on the material and test requirements. Adjustments are made via the user-friendly touchscreen or microcomputer controls prior to initiating each test.
Q: Where can the data output from the test be saved or printed?
A: Test results can be exported to a USB drive, printed via a thermal printer, or sent to a connected Windows analysis software for further processing and reporting.
Q: What is the process for mounting film specimens in the tester?
A: Specimens, typically 15 mm x 150 mm in size, are secured using adjustable film grips that hold the sample firmly in place, ensuring accurate tensile measurements for each test.
Q: What are the benefits of using this digital tensile testing machine?
A: The machine offers precise and automated test processes, robust safety mechanisms, multiple data output options, and compatibility with different software, making it ideal for both laboratory and industrial applications.
Q: How can the equipment be used in multilingual environments?
A: The tensile tester features selectable user interface languages, allowing operation in both English and Chinese, ensuring accessibility for a diverse range of operators.