Product Description
High Precision
- Patented test chamber and test dishes with advanced fluid dynamics and thermodynamic designs.
- Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
- Precise and scientific regulation and calculation of testing conditions.
High Efficiency
- 6 test stations
- Supports test modes of desiccant method and water method
Labor Saving
- Automatic humidity and flow rate controlling.
- Desiccator requires no replacement of inner core.
- High-efficiency water vapor generator.
Simplified Operation
- 12 touch-screen pad powered by WindowsTM 10 operating system
- Fast automatic testing process
- Optional DataShieldTM software and accessories for automatic data management
Product Features
New Generation Test Chamber and Test Dishes
Patented test chamber and test dishes with advanced and thermodynamic designs ensure the uniform flow rate over the specimen surface, stable temperature and humidity, creating a uniform and stable testing environment. As a result, the test duration is shortened and the test results will be more accurate.
Excellent Testing Abilities of High and Low Barrier Materials
The testing conditions will be regulated precisely in real time, which ensures the high testing accuracy and repeatability of high and low barrier materials.
Automatic Controlling of Temperature, Humidity and Air Velocity
Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
Air velocity is monitored and regulated in real time.
High-efficiency and mist-free automatic humidity regulator meets the requirements for long-term continuous tests.
It is unnecessary to replace the inner core of the desiccator, which can continuously work for 20,000 hours.
Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system facilitates centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.
User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.
Test Principle
The test specimen is mounted in the test dish which contains water or desiccant inside. The test dish is placed in the test chamber with stable temperature, humidity and air flow. The water vapor permeates through the specimen and into the dry side. By measuring the weight changes of the test dish periodically, water vapor transmission rate and other parameters can be obtained.
Test Standards
ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, GB/T 1037, GB/T 16928, YBB 00092003-2015
Applications
| Basic Applications |
- Films
Plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminum coated films, aluminum foil composite films, glass fiber aluminum foil paper composite films and many other film materials
|
- Sheeting
PP, PVC and PVDC sheeting, metal foils, rubber pads and other sheeting materials
|
- Paper and Paper Board
Aluminum coated paper for cigarette, paper aluminum plastic composite film and other paper and paperboards
|
- Textiles and Nonwovens
Textiles and nonwoven fabrics
|
| Extended Applications |
- Construction Materials
Geotextiles, felt, roofing and building materials, vapor barrier membranes, etc.
|
- Aseptic Wound Protection Films and Medical Plasters
Aseptic wound protecting films, medical plasters and protective clothing materials
|
Technical Specifications
Table 1: Test Parameters Note1
| Parameter |
Model C360M |
| Testing Efficiency |
0.01g/(m2day) 0.5g/(m2day) |
>24 hours |
| 0.0006g/(100in2day) 0.0323g/(100in2day) |
| 0.5 g/(m2day)5 g/(m2day) |
12 24 hours |
| 0.0323g/(100in2day) 0.3225g/(100in2day) |
| > 5 g/(m2day) |
8 hours |
| > 0.3225 g/(100in2day) |
| Max. Test Range |
Water Method |
10000/ni141-6i14g/(m2day) |
| 645/ni141-6i14g/(100in2day) |
| Desiccant Method |
1200g/(m2day) per piece |
| 77g/(100in2day) per piece |
| Test Station |
|
6 |
| Test Temperature |
C |
20 55 0.2 |
| Test Humidity |
RH |
10% 90% 1% |
| Additional Functions |
DataShieldTM Note2 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Specimen Size |
I74mm |
| Specimen Thickness |
3mm |
| Test Method |
Desiccant Method / Water Method |
| Standard Test Area |
33cm2 |
| Carrier Gas |
Compressed Air |
| Drying of Carrier Gas |
Long Service-life Desiccator (unnecessary to replace inner core) |
| Humidifying of Carrier Gas |
High-efficiency mist-free humidity generator |
| Carrier Gas Pressure |
0.6 MPa |
| Port Size |
I6mm PU Tubing |
Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.
Precision Measurement with Advanced Hydrostatic Head TestingEmploying the hydrostatic head method, this lab instrument delivers accurate water barrier performance evaluation for waterproof fabrics. Its digital display presents measurements up to 2000 mm H2O, ensuring precision and consistency. The device supports fast and responsive results with a response time of 2 seconds, tailored to a variety of textile applications.
User-Friendly Design with Multilingual Touchscreen InterfaceNavigating test procedures is straightforward thanks to the multilingual touchscreen, which simplifies configuring parameters and accessing test data. Combined with microcomputer controls and digital feedback, users can efficiently operate the device and retrieve historical results. Firmware upgrades are supported via USB for seamless software improvements.
Robust Safety and Compliance FeaturesSafety is prioritized with over-pressure protection and automatic shutoff, ensuring secure operation in laboratory environments. Compliance with ISO 811 and AATCC 127 standards verifies that test results meet global regulatory requirements, further boosted by factory calibration and certification. This makes the instrument fully suited for professional textile laboratories.
FAQ's of Lab Instrument for Evaluate Waterproof Fabric Water Barrier Performance:
Q: How does the lab instrument evaluate the waterproof performance of fabric?
A: The instrument uses the hydrostatic head method, applying a controlled water column pressure to a fabric specimen and digitally measuring the resistance until water penetration occurs. Test results indicate the water barrier efficiency in mm H2O.
Q: What types of fabrics can be tested with this device?
A: This machine is designed for waterproof textiles of various compositions, allowing manufacturers, suppliers, and laboratories to assess and compare the water permeability of coated, laminated, and treated fabrics.
Q: Where should the instrument be installed for optimal use?
A: Installation is recommended in laboratories with a non-condensing, dust-free environment, ensuring stable ambient conditions (temperature 10C-40C, humidity 30%-85% RH) for accurate performance.
Q: What safety measures are integrated into this equipment?
A: The device incorporates over-pressure protection and automatic shutoff to prevent damage or hazards during operation. These enhance security for both the operator and the equipment.
Q: How is test data managed and stored?
A: Up to 1000 individual test results can be stored within the instrument, accessible for review on the digital touchscreen interface. Data export is supported via RS232 or USB connectivity.
Q: When should the instrument be recalibrated?
A: The equipment comes factory-calibrated with certification. Recalibration should be carried out periodically or according to lab protocols to maintain measurement accuracy.
Q: What benefits does the semi-automatic control provide for users?
A: Semi-automatic functionality enables precise adjustment of test speed (10-300 mm/min) and test parameters, streamlining the workflow and minimizing operator intervention for consistent and repeatable results.