Product Details:

  • Resolution 0.01 N
  • Application High-barrier integrity testing for pharmaceutical blister packs
  • Number of Specimens 1 to 5
  • Hardness Applicable for aluminum-plastic blister packs
  • Mounting Type Benchtop
  • Measuring Range 0 to 3000 N
  • Humidity 20% to 80% RH
  • Click to View more
X

Sensitive Pharmaceuticals High-Barrier Aluminum-Plastic Blister Packs Testing Instrument Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set
  • 50000 USD ($)/Set
  • Indoor use only
  • Up to 500 test records
  • Capacitive load cell
  • PC Control Software included
  • Dust-free, vibration-free area recommended
  • White/Grey
  • Meets GMP, ISO 15378 standards
  • Pressure decay and differential pressure
  • Overload protection, emergency stop
  • Auto-calibration function

Sensitive Pharmaceuticals High-Barrier Aluminum-Plastic Blister Packs Testing Instrument Product Specifications

  • 0 to 3000 N
  • Microcomputer control
  • 5 to 200 mm/min (adjustable)
  • 300 mm
  • 85 kg
  • 0.6 MPa
  • RS232/USB
  • 50 Hz
  • AC 220V
  • 0.5% F.S.
  • Automatic
  • <2 seconds
  • 900 mm
  • Sensitive Pharmaceuticals High-Barrier Aluminum-Plastic Blister Packs Testing Instrument
  • Max load 3000 N
  • 15C to 35C
  • Digital LCD
  • AC 220V, 50 Hz
  • 0.01 N
  • High-barrier integrity testing for pharmaceutical blister packs
  • 1 to 5
  • Applicable for aluminum-plastic blister packs
  • Benchtop
  • 0 to 100 mm
  • Blister pack leak and integrity testing
  • 0 to 3000 N
  • 20% to 80% RH
  • High-precision, touch screen, automatic data recording
  • 8 mm
  • customizable, max 150 mm x 100 mm
  • Indoor use only
  • Up to 500 test records
  • Capacitive load cell
  • PC Control Software included
  • Dust-free, vibration-free area recommended
  • White/Grey
  • Meets GMP, ISO 15378 standards
  • Pressure decay and differential pressure
  • Overload protection, emergency stop
  • Auto-calibration function

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

High Efficiency Three-cell

  • Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
  • Three samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C403H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.01 200
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.01 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.005 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.005 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.05
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 test chambers
Specimen Size 4.4 x 4.4i1411.2cm11.2cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Precision and Compliance in Blister Pack Testing

Meeting international GMP and ISO 15378 standards, this instrument ensures pharmaceutical blister packs are thoroughly tested for high-barrier integrity. Its capacitive load cell delivers accurate force measurement, critical for detecting leaks or integrity issues in aluminum-plastic packaging.


Automated Data Storage and Intuitive Operation

The built-in microcomputer and PC control software streamline testing and data management. Automatically store up to 500 records, while adjustable parameters and a digital touch screen enhance usability, making compliance and reporting easy for quality control teams.


Robust Safety and Environmental Adaptability

Equipped with overload protection and emergency stop functions, this tester prioritizes user safety. Designed for indoor, dust-free, and vibration-free operation, it suits modern laboratories and manufacturing environments ensuring consistent and accurate testing outcomes.

FAQ's of Sensitive Pharmaceuticals High-Barrier Aluminum-Plastic Blister Packs Testing Instrument:


Q: How does the instrument perform leak and integrity testing on pharmaceutical blister packs?

A: The instrument utilizes pressure decay and differential pressure methods to assess high-barrier aluminum-plastic blister packs. Specimens are subjected to controlled pressure, and any changes detected by the capacitive load cell signal potential leaks or compromised integrity.

Q: What software and data management features are provided?

A: PC control software is included, enabling automated test setup, real-time monitoring, and digital storage of up to 500 test records. Data can be exported via RS232 or USB interfaces for analysis and compliance documentation.

Q: When should auto-calibration be performed and how is it initiated?

A: Auto-calibration is recommended before starting a new batch of tests or after maintenance. The process is activated through the touch screen interface, ensuring consistent measurement accuracy without manual intervention.

Q: Where should the instrument be installed for optimal performance?

A: For best results, place the instrument in an indoor environment that is dust-free and free of vibrations, ideally within a laboratory or controlled manufacturing space. This guarantees logical and reproducible test outcomes.

Q: What is the process for testing multiple specimens at once?

A: The instrument supports testing 1 to 5 blister pack specimens per cycle. Specimens can be customized in size (up to 150 mm x 100 mm) and securely mounted on the benchtop device, where test speed and parameters are adjusted to meet specific requirements.

Q: How does the instrument benefit pharmaceutical manufacturers and exporters?

A: High accuracy and compliance with GMP and ISO 15378 standards protect product quality and streamline regulatory approval. Automated operation and fast response time (<2 seconds) accelerate batch testing, boosting productivity and confidence in the packaging process.

Q: What are the primary usage scenarios for this blister pack testing instrument?

A: Primarily used for leak and integrity tests, the instrument is essential for quality control in pharmaceutical manufacturing, research, and export compliance. Its versatility makes it suitable for aluminum-plastic blister packs requiring precise barrier validation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.