Call Us
Send Inquiry    Call Me Free
Key Quality Assurance Testing Parameters for Ampoule Bottles

Key Quality Assurance Testing Parameters for Ampoule Bottles

50000 USD ($)/Set

Product Details:

  • Power Supply 220V AC, 50/60 Hz
  • Automation Grade Semi-automatic
  • Number of Specimens Up to 5
  • Temperature 10C to 40C
  • Humidity 20% - 90% RH
  • Mounting Type Bench-Top
  • Frequency 50/60 Hz
  • Click to View more
X

Key Quality Assurance Testing Parameters for Ampoule Bottles Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set
  • 50000 USD ($)/Set

Key Quality Assurance Testing Parameters for Ampoule Bottles Product Specifications

  • 1% of reading
  • 220V AC
  • Approx. 30-40 kg
  • As per ISO/ASTM standard
  • Standard 8 mm
  • Automatic data logging, Overload protection
  • Breakage, compression, and leak resistance testing
  • Mechanical strength/quality testing of ampoule bottles
  • Up to 0.8 MPa
  • 0.01 N
  • USB/RS232
  • <1 s
  • Customizable as per ampoule bottle size
  • 0-500 N
  • 50-500 ml
  • 20% - 90% RH
  • 10C to 40C
  • 50/60 Hz
  • Bench-Top
  • Up to 5
  • 220V AC, 50/60 Hz
  • 50-500 mm/min
  • Semi-automatic
  • Up to 300 mm
  • 0-300 mm
  • Ampoule Bottle Quality Tester
  • Digital / Microprocessor-based
  • Digital LCD / LED
  • 300 mm
  • 0-500 N

Product Description

Product FeaturesNote1

Ten Test Modes to Meet Various Testing Demands

  • Ten independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, puncture test of rubber closure and puncture retention force test, etc. at users choice
  • The instrument supports bidirectional testing modes, which can be used for puncture test of rubber closure and breaking force test of ampoule and test speed can be adjusted freely
  • Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users

Excellent Testing Mechanism & Improved Test Accuracy

  • Force measuring system is supplied by top global supplier, ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
  • Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
  • Global renowned brand pneumatic control system supports pneumatic specimen clamping, avoids the specimen slipping and guarantees the accuracy of test data

High-end, Secure and Easy-to-Use Embedded Computer-controlled System

  • The instrument is integrated with software requiring no external computer
  • The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
  • Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
  • The instrument is equipped with USB ports and Internet ports for convenient data transmission.
  • Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.

Test StandardNote1

ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130

Applications

C610M is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:

Basic Applications
  • Shearing Test
  • Test of Tensile Strength and Elongation Rate
  • Test of Tensile Strength at Break
  • Tear Resistance Test
  • Heatseal Strength Test
  • 90 Degree Peel Test
  • 180 Degree Peel Test
  • Tensile Strength Test at Defined Elongation
Extended Applications
(Additional Accessories Required)
  • Puncture Test of Hypodermic Needles in Artificial Skin
  • Puncture Test of Films
  • Puncture Test of Infusion Bags
  • Puncture/Pullout Test of Flexible Rubber Closures
  • Opening Resistance Test of Combined Covers
  • Tear Test of ZD - Type Caps
  • Opening Force Test of Oral Liquid Caps
  • Puncture/Pullout Test of Oral Liquid Caps
  • 90 Degree Pullout Test of Infusion Bag Caps
  • Pullout Test of Infusion Bag Caps
  • 23 Degree Pullout Test of Bottle Caps
  • Puncture/Pullout Test of Bottle Caps or Rubber Closures
  • 90 Degree Peel Test of Adhesive Tapes
  • Tear Resistance Test of Adhesive Binding Books
  • 90 Degree Peel Test of Water-soluble Plasters
  • Tear Resistance Test of Adhesives
  • Adhesive Strength Test (soft)
  • Adhesive Strength Test (hard)
  • Peel Test of Flexible Tube Caps
  • Removal Force of Pipes and Pipe Joints
  • Pullout Test of Cosmetic Brush Hair
  • Pullout Test of Tooth Brush Hair
  • Tensile Strength of Ropes at Break
  • Opening Force Test of Jelly Cups and Yogurt Cups
  • Peel Test of Cup Films
  • Pullout Test of Rubber Stoppers
  • 45 Degree Peel Test of Bottle Membranes
  • Tensile Strength of Sealing Bags
  • Peel Test of Magnetic Cores
  • 90 Degree Peel Test of Magnetic Cards
  • Tear Resistance of Heat Sealing Films
  • Separating Force of Protection Films
  • Peel Test of Release Paper
  • Tear Test Using Trouser Method
  • Unwrapping Force of Adhesive Tapes
  • Compressive Resistance of Plastic Bottles
  • 20 Degree Peel Test
  • 135 Degree Peel Test of Plugs
  • Peeling Grips of Floating Rollers
  • Eccentric Grips
  • Wide Sample Grips
  • Japanese Sample Grips
  • British Sample Grips
  • Tensile Strength of Contact Lenses at Break
  • Compression Resistance of Jelly Cups
  • Compression Resistance of Package
  • Compression Resistance of Sponge
 

Technical Specifications

Specifications C610M Auto Tensile Tester
Load Cell Capacity 500 N (standard)
50 N, 100 N, 250 N, 1000 N (optional) 5N (Customization available)
Accuracy 0.5% of indicated value (2%FS 100%FS)
0.01%FS (0% 2%FS)
Resolution 0.001 N
Test Speed 0500 mm/min
Speed Accuracy 0.5% of indicated value
Number of Specimens 1
Specimen Width 30 mm (Standard Grip)
50 mm (Optional Grip)
Clamping Way Pneumatic Specimen Clamp
Gas Supply Air (outside of supply scope)
Gas Supply Pressure 0.5 MPa 0.7 MPai1472.5psii101.5psii14
Stroke 950 mm (customization available for 1200mm)
Instrument Dimension 450 mm (L) x 450 mm (W) x 1410 mm (H)
Power Supply 220VAC10% 50Hz / 120VAC10% 60Hz
Net Weight 95 kg

Configurations

Standard Configurations
Instrument (with embedded software), LCD Monitor, Keyboard, Mouse, Pneumatic Sample Girps
Optional Parts
Standard Pressure Roller, Test Plate, Sample Cutter, Air Compressor
Note
1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.

Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Reliable and Advanced Testing

Designed for rigorous quality assessments, this ampoule bottle tester combines microprocessor-based controls and digital interfaces (USB/RS232) to provide reliable data, quick response times (<1 s), and automatic data logging. It supports comprehensive reporting and ensures specimen integrity through multi-level password protection and safety shutdown protocols.


Versatile Application and Compliance

Able to process up to 30 samples per hour, the tester suits manufacturers and exporters needing compliance with ISO, USP, and ASTM standards. Its compatibility with borosilicate and neutral glass makes it highly adaptable, and the customizable specimen sizing meets diverse production requirements.

FAQ's of Key Quality Assurance Testing Parameters for Ampoule Bottles:


Q: How is the calibration performed on the Ampoule Bottle Quality Tester?

A: Calibration can be conducted either manually or automatically, and the device supports traceable certificates to guarantee accuracy. Regular calibration should be performed according to your ISO or ASTM standards and before high-throughput or critical testing batches.

Q: What compliance standards does the tester meet and why are these important?

A: This equipment complies with ISO 7208, USP, and ASTM E438 standards, ensuring reliable, repeatable, and internationally accepted test results for ampoule bottles. Compliance is crucial for quality assurance, regulatory approvals, and global market entry.

Q: When and where should the Ampoule Bottle Quality Tester be used for optimal results?

A: For best accuracy and machine longevity, operate this tester in a dust and vibration-free environment, within the recommended temperature (10C to 40C) and humidity range (20% - 90% RH). It's ideal for use in glass manufacturing, pharmaceutical labs, and quality control departments.

Q: What is the process for conducting a test on ampoule bottles?

A: To initiate a test, prepare specimens as per required bottle size and capacity, set the desired test speed, width, and stroke, and use the digital interface to start the procedure. The tester measures mechanical properties such as breakage, compression, and leak resistance, with real-time digital display and automatic data logging.

Q: How does the control software and data storage benefit the user?

A: A PC interface enables efficient report generation and data review. Storing up to 10,000 results, the system supports easy traceability and regulatory inspections and enhances batch quality monitoring. User access is managed through password-protected, multi-level authorization to safeguard sensitive data.

Q: What safety features are incorporated in the equipment?

A: The tester integrates emergency stop and over-temperature shutdown mechanisms, and overload protection, ensuring safe operation in demanding environments. These features protect both users and fragile ampoule specimens during intensive quality testing.

Q: How does this tester improve ampoule bottle quality assurance?

A: With accurate measurements (1% of reading), customizable testing parameters, and robust data management, the tester identifies defects early, reduces breakage risks, and assures producers of batch conformity, ultimately supporting consistent product quality and customer safety.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Tensile Testing Machines' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.