Call Us
Send Inquiry
Package Oxygen Permeability Testing System

Package Oxygen Permeability Testing System

200.0 USD ($)/Set

Product Details:

  • Response Time 10 s
  • Power Supply AC 220V, 50Hz
  • Temperature 15-50C adjustable
  • Test Range 0.01-10,000 cc/(m224hatm)
  • Accuracy 1% of reading
  • Mounting Type Tabletop
  • Humidity 0-100% RH
  • Click to View more
X

Package Oxygen Permeability Testing System Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 200.0 USD ($)/Set

Package Oxygen Permeability Testing System Product Specifications

  • 0.1-0.6 MPa
  • Package Oxygen Permeability Testing System
  • 0.01 cc/(m224hatm)
  • Approx 60 kg
  • 100 mm x 100 mm
  • 400 mm
  • Automated, High Accuracy, Multi-Language Support, Real-time Data Output
  • RS232/USB
  • 220V AC
  • 0.01-10,000 cc/(m224hatm)
  • Fully Automatic
  • 1-3
  • Oxygen transmission rate measurement for packaging materials, films, containers, bottles.
  • 150 mm
  • 0.01-10,000 cc/(m224hatm)
  • 15-50C adjustable
  • AC 220V, 50Hz
  • 10 s
  • 6 mm
  • LCD Display
  • Single/Multiple Testing Options
  • 0-300 mm
  • 50Hz
  • 0.1-5 ml/min adjustable
  • Microcomputer controlled
  • Tabletop
  • 0-100% RH
  • Lab/Industrial
  • 1% of reading

Product Description

High Precision

  • Patented integrated test block with advanced hydrodynamic and thermodynamic designs.
  • Labthinks proprietary thermostat technology ensures that the test block is precisely temperature controlled and remains stable throughout the test.
  • Temperature and humidity sensor for independent monitoring of test cells.

High Efficiency

  • Three identical specimens can be tested simultaneously, which meets the requirements for parallel test.
  • Three distinct specimens can be tested under the same testing condition, delivering higher throughput while reducing the number of instruments required.

Labor Saving

  • Automatic temperature and humidity control eliminates the need for operator monitoring and adjustment.
  • Automatic flow rate control ensures constant flow during the testing process and minimizes any errors caused by an unstable flow rate.
  • No need to verify the system using different reference film for different testing range.

Simplified Operation

  • 12 touch-screen pad powered by WindowsTM 10 operating system
  • Fast automatic testing process
  • Optional DataShieldTM software and accessories for automatic data management

Product Features

New Generation Integrated Testing Block
The patented three-cell integrated test block structure using advanced thermodynamics and hydrodynamics analysis greatly improves the temperature, humidity and flow measurement accuracy across the three test cells and supports simultaneous testing of three samples.

Automatic Control of Temperature, Humidity and Flow Rate
The internal temperature and humidity of the instrument are automatically adjusted with temperature and humidity sensors, maintaining the stability of the test specimen environment.
Automatic flow rate control ensures the constant flow during the testing process and minimizes any errors caused by an unstable flow rate.

Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system, meets the requirements for centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.

User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.

Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.

Test Principle

The pre-conditioned specimen is mounted between the upper and lower chambers at ambient atmospheric pressure. The upper chamber contains oxygen or air and the lower chamber is slowly purged by a stream of nitrogen. Due to the concentration difference between the two chambers, oxygen molecules permeate through the specimen into the nitrogen side and are taken to the coulometric sensor where proportional electrical signals are generated. The oxygen transmission rate is then obtained by analyzing the signals and calculating the volume of oxygen measured by the sensor. For whole package samples, high purity nitrogen flows inside the package, and oxygen or air flows outside.

Test Standards

ASTM D3985, ASTM F1307, ASTM F1927 (option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B and YBB 00082003-2015

Applications

Basic Applications
  • Films
    Plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheeting
    PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheeting materials
  • Packages
    Plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tubes for toothpaste, jelly and yogurt cups
Extended Applications
  • Closure Systems
    Oxygen barrier property of various closure systems for bottles cartons and pouches.
  • Solar Back-Sheets
    Oxygen permeability test of solar back-sheets
  • Plastic Tubes
    Oxygen permeability test of various sorts of tubes, e.g cosmetic tubes.
  • Blister Packs
    Test oxygen transmission rate of the whole blister packs
  • Automotive and Small Engine Fuel Tanks
    Permeability of plastic fuel tanks.
  • Battery Plastic Shell
    Oxygen transmission rate of battery plastic shell

Technical Specifications

Table 1: Test Parameters Note1

Parameter Model C230H
Test Range cm3/(m2d) (Standard) 0.01 200
cc/(100in2day) 0.0007 12.9
cm3/(pkgd)(Package) 0.00005 1
Resolution cm3/(m2day) 0.001
Repeatability cm3/(m2day) 0.01 or 2%
Test Temperature C 10 55 0.2
Test Humidity RH O2: 0%, 5% 901%, 100%
Carrier Gas: 0%, 5% 902%(optional)
Additional Functions Package Test (3L Max.) Optional
DataShieldTM Note2 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 test chambers
Specimen Size 108 mm X 108 mm
Specimen Thickness 3 mm
Standard Test Area 50 cm2
Carrier Gas 99.999% High-purity Nitrogen (outside of supply scope)
Carrier Gas Pressure 0.28 MPa/40.6psi
Port Size 1/8 inch metal tubing


Advanced Oxygen Transmission Testing

Utilize cutting-edge zirconia sensor technology for precise measurement of oxygen permeability in diverse packaging materials. The unit delivers quick results with an adjustable test speed and a wide measuring range, making it ideal for research labs and industrial quality control alike.


Automated and User-Friendly Operation

This package testing system features a microcomputer control interface, large LCD display, and automated calibration options. Multi-language support and touchscreen operation streamline testing for users of all experience levels, ensuring accuracy and efficiency with every test.


Comprehensive Data Management

Store up to 10,000 test results with seamless exporting options in CSV, Excel, or PDF formats. With RS232/USB connectivity, real-time data output, and reliable performance under variable conditions, this system meets modern documentation and traceability requirements for packaging testing.

FAQ's of Package Oxygen Permeability Testing System:


Q: How does the Package Oxygen Permeability Testing System measure oxygen transmission rates?

A: The system uses a high-sensitivity zirconia sensor to detect and quantify the rate at which oxygen permeates through packaging materials. Tests are fully automated and microcomputer-controlled, ensuring precise and repeatable results that comply with ASTM, ISO, and JIS standards.

Q: What types of materials and packaging can be tested with this equipment?

A: You can use the system to test a wide range of materials, including packaging films, containers, and bottles. Its flexibility allows for single or multiple specimen analysis, accommodating various material sizes up to 100 mm x 100 mm.

Q: Where is this system typically used?

A: This testing equipment is ideal for use in both laboratory and industrial settings. It is widely adopted by manufacturers, research institutions, and quality control departments to ensure the durability and barrier performance of packaging materials against oxygen transmission.

Q: What is the process for conducting a test using this system?

A: Testing involves mounting your specimen, selecting the test parameters via the LCD display, and starting the test. The system automatically controls temperature, humidity, and gas flow. Within ten seconds, the sensor begins collecting data, and results are stored and available for export after completion.

Q: How is calibration performed, and how frequently is it needed?

A: Calibration can be completed automatically or manually as needed. The system prompts users when calibration is recommended, ensuring ongoing accuracy and compliance with regulatory standards. Regular calibration is advised based on usage intensity and quality requirements.

Q: What are the main benefits of using this package oxygen permeability system?

A: Key advantages include high measurement accuracy (1%), fast response time ( 10 s), automated operation, robust data management capabilities, and compliance with international testing standards. These features help improve packaging quality and reduce product spoilage due to oxygen ingress.

Q: Can the system operate under different environmental conditions?

A: Yes, the equipment performs reliably across a broad temperature range (5-40C operating, 15-50C adjustable for tests) and humidity range (0-100% RH), making it suitable for diverse environments and applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Packaging Testing Instrument' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.