Product Details:

  • Number of Specimens 1~3 (parallel testing possible)
  • Interface Type RS232, USB
  • Automation Grade Automatic
  • Port Size Customized
  • Equipment Type Permeability Testing Machine
  • Power Supply AC220V/50Hz
  • Application Material permeability testing for films, textiles, membranes, packaging, construction materials etc.
  • Click to View more
X

Exploring Materials Permeability Test Methods and Instrumentation Price And Quantity

  • 50000 USD ($)/Set
  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set

Exploring Materials Permeability Test Methods and Instrumentation Product Specifications

  • <3s
  • Customizable according to material type
  • 0-50N
  • 108 mm diameter
  • 0.1~10000 g/m224h
  • 30 mm
  • 650 mm
  • 30-90% RH (adjustable)
  • AC220V/50Hz
  • Laboratory/Quality Control
  • 0.6 MPa (max)
  • 43 kg
  • Material permeability testing for films, textiles, membranes, packaging, construction materials etc.
  • Automatic
  • Permeability Testing Machine
  • Customized
  • Microcomputer control, manual mode
  • RS232, USB
  • 1~3 (parallel testing possible)
  • 0.01 g/m224h
  • 50 Hz
  • 700 mm
  • Data logging, automatic calculation & print output, leak proof chamber design
  • Compatible for soft/hard specimen adjustment
  • Benchtop
  • 10-50C (adjustable)
  • 0.2% F.S.
  • LCD Digital Display
  • 220 V
  • 0.01~500 mm/min (adjustable)

Product Description

Product FeaturesNote1

Accurate Data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.010.09cm3/ m324h0.1MPa test range.
  • Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
  • Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
  • The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
  • Labthinks unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
  • The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.

High Efficiency

  • Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Medium and low barrier materials, test time <4 hours (including vacuumize time).
  • High barrier materials, test time <4 hours (including vacuumize time).
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert

Safe and reliable

  • System security -- Built-in Labthinks unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
  • Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Tests of hazardous gases such as H2CH4 are applicable (Customize).

Test Principle

The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.

Standard

ISO 15105-1ISO 2556GB/T 1038-2000ASTM D1434JIS K7126-1YBB 00082003

Applications

Applications
  • Films
    Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C106H
Test range cm3/m224h0.1MPa 0.0150,000
Resolution cm3/m224h0.1MPa 0.001
Test temperature 1550560Optional
Temperature resolution 0.01
Temperature fluctuation 0.15
Test humidity %RHWithin standard test temperature range 0%5902%Customize
Vacuum Resolution Pa 0.01
Vacuum Accuracy Pa 0.2%1%-100% of Full Scale
Vacuum Degree of Test Chamber Pa 10
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.611.7cm11.7cm
Specimen Thickness 120 Mil3mm
Standard test area 38.48cm2
Test Gas O2N2CO2 etc.Outside of supply scope
Test Pressure 10 kPa210 kPaCan be set between
Pressure Fluctuation 0.2 kPa
Gas Pressure 79.7 PSI / 550 kPa
Port Size 6 mm PU tubing
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz/220VAC10% 50Hzone of two
Net Weight 220Lbs100kg

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, 6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas compressor port of the instrument is 6 mm PU tubingpressure79.7 PSI/ 550kPa, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Advanced Gas Transmission Testing Principle

This equipment employs the Gas Transmission Method to accurately evaluate the permeability of materials such as films, membranes, textiles, and construction components. The method ensures reliable results, complying with ISO and ASTM standards for quality assurance. Its microcomputer and manual control modes provide flexibility and precision during testing.


Flexible Test Parameters and Automation

Featuring adjustable temperature (1050C), humidity (3090% RH), test speed (0.01500 mm/min), and customizable measuring ranges, the machine adapts to distinct material requirements. Automatic or manual calibration, data logging, and built-in sample preparation tools streamline laboratory workflows, making it highly efficient for consistent material testing.


User-Friendly and Reliable Performance

The machine is engineered for quiet indoor operation with noise levels below 60 dB, and can store up to 10,000 test results. Its alarm system (acoustic and visual) enhances user safety, while an LCD digital display, quick response time (<3 s), and robust leak-proof chamber ensure dependable results. It operates on standard AC220V/50Hz power.

FAQs of Exploring Materials Permeability Test Methods and Instrumentation:


Q: How does the Gas Transmission Method work in this permeability testing machine?

A: The Gas Transmission Method measures how much gas passes through a material under controlled temperature, humidity, and pressure. This testing machine creates a stable environment, applies specified gas pressure, and quantifies the transmission, providing precise permeability data in line with ISO and ASTM standards.

Q: What materials can be tested using this permeability machine?

A: The equipment is suitable for films, membranes, textiles, packaging materials, and construction components. Its measuring range and customizable parameters allow it to handle both soft and hard specimens, making it versatile for research, quality control, and industrial applications.

Q: When should I use automatic versus manual calibration?

A: Automatic calibration is ideal for routine, frequent testing, ensuring consistent and accurate results with minimal effort. Manual calibration can be used for special materials, validation, or when fine-tuning is necessary to match specific standards or material properties.

Q: Where is the best place to install this permeability testing machine?

A: This benchtop instrument should be installed indoors in a clean, dust-free laboratory or quality control environment to maintain its performance and prevent sample contamination. Ensure access to AC220V/50Hz power and use on a stable surface for accurate results.

Q: What steps are involved in the specimen testing process?

A: Begin by preparing specimens using the included tools. Place the sample in the leak-proof chamber, set the required temperature, humidity, and gas pressure, and select the test parameters. Start the test using microcomputer or manual mode; the machine will record, display, and store results automatically.

Q: How is test data managed and exported from the machine?

A: Test results are automatically savedwith capacity for up to 10,000 entriesin the machines memory. Data can be transferred using USB or RS232 interfaces to Windows-based software for further analysis, report generation, or print output, supporting efficient lab workflows.

Q: What are the benefits of using this permeability testing machine?

A: Users gain reliable, standards-compliant permeability measurements with flexible operation, high accuracy (0.2% F.S.), rapid response (<3s), and efficient data handling. The parallel testing capability and customizable settings help increase testing throughput and support diverse application needs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.