Call Us
Send Inquiry    Call Me Free
Packaging Material Testing to Prevent Food Oxidation

Packaging Material Testing to Prevent Food Oxidation

50000 USD ($)/Set

Product Details:

  • Power Supply 220V AC, 50Hz
  • Temperature 15C 40C
  • Humidity 20% - 90% RH
  • Gas Pressure 0.10.5 MPa
  • Measuring Range 0.01 10 cm/mday
  • Hardness Test chamber hardened alloy
  • Accuracy 1% FS
  • Click to View more
X

Packaging Material Testing to Prevent Food Oxidation Price And Quantity

  • 50000 USD ($)/Set
  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set

Packaging Material Testing to Prevent Food Oxidation Product Specifications

  • 400 mm
  • 50-60 Hz
  • Benchtop
  • Microprocessor-based automatic control
  • 1 3
  • 10-100 mm/min
  • 0.01 cm/mday
  • 0 100% O2 or CO2
  • 220V AC
  • Anti-oxidation measurement, leak detection, data storage
  • 10 seconds
  • RS232/USB
  • Food packaging analysis
  • LCD digital display
  • 0.01 10 cm/mday
  • Test chamber hardened alloy
  • 1/4 inch NPT
  • 1% FS
  • 200 mm
  • 0.10.5 MPa
  • Variable as per test requirements
  • 0 300 mm
  • 15C 40C
  • 220V AC, 50Hz
  • 20% - 90% RH
  • Packaging Material Testing Equipment
  • 45 kg
  • 100 mm x 100 mm
  • Testing packaging material performance to prevent food oxidation
  • Automatic

Product Description

Product FeaturesNote1

Coulometric Oxygen Sensor

  • The instrument is equipped with ppb level Coulometric Oxygen Sensor of Labthink which can obtain lower test limit.
  • Designed according to ASTM D3985 with absolute value and no need to calibrate.
  • Super long service life, three times longer than traditional Coulometric oxygen sensor.
  • Functions of over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, real-time monitoring and recording temperature and humidity changes.
  • In the test process, the automatic control of flow, temperature and relative humidity is realized, and the accuracy is higher.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

Effective Three-Cell

  • Independent three sets of 50cm2 standard test area cells, in line with the standard requirements for parallel sample detection.
  • Three samples are tested at the same time under the same condition, and the data are independent.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic clamping sample, saving time and labor, clamping force is consistent, better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting the test temperature and humidity and clicking one key to start the test, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: the innovative Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus, and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as sound and light intelligent alarms to ensure the safety of operation.
  • Safe Performance: the instrument uses global famous brand with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and rich control functions to meet the needs of scientific research.
  • Provide oxygen permeability curve, oxygen transmission coefficient curve, temperature curve and humidity curve.
  • Ultra wide test range, meet the barrier test (customized) of various materials.
  • Ultra wide temperature range, meet the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen free carrier gas (optional).

Testing Principle

The sample is clamped between the test chambers, oxygen or air flows on one side of the film, and high-purity nitrogen flows on the other side of the film. Oxygen molecules diffuse through the film into the high-purity nitrogen in the other side. The flowing nitrogen is carried to the sensor. Through the analysis of the oxygen concentration measured by the sensor, the oxygen transmittance is calculated.

Reference Standards

ASTM D3985, ASTM F1307, ASTM F1927(option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

Test Applications

Applications
  • Films
    The oxygen permeability tests of various plastic films, paper plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film like materials.
  • Sheet
    The oxygen permeability tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Parameters

Table 1: Test Parameters Note2

Parameters/Model C203H
Test Scope cc/(m2day) (standard area 50cm2) 0.01i200
0.005i200 (optional)
cc/(m2day) (standard area 50cm2) 0.01i400000i14Customizei14
cc/(m2day) (MASK area 5cm2) 0.12000 (optional)
cc/(m2day) (MASK area 1cm2) 0.510000 (optional)
Resolving Power cc/(m2day) 0.0001
Repeatability cc/(m2day) 0.01 or1%, whichever is greater
Temperature Range  15i50
560 (customized)
Temperature Fluctuation 0.05
Humidity Range %Rh (within standard temperature range) O2: 0%i145i901%
Carrier Gas: 0%, 5i902%
Extended Functions GP-01 Gas Purification Unit Optional
DataShieldTM Data Shield Note 3 Optional
GMP Computer System Requirements Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 sets
Sample Size 4.4 x 4.4i1411.2cm11.2cmi14
Sample Thickness 120 Mili143mmi14
Standard Test Area 50cm2
Gas Specification 99.999% nitrogen, 99.5% oxygen (gas source prepared by the buyer)
Air Source Pressure 40.6 PSI / 280 kPa
Interface Size 1 / 8 "metal tube
Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Power Supply 120VAC 10% 60Hz / 220VAC 10% 50Hz (choose one from those two)
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbs(100kg)

Table 3: Product Configuration

Standard Configuration Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm
Options Gp-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements
DataShieldTM Data ShieldNote3
Remarks The compressed air inlet of the machine is I 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the buyer.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.



Reliable Detection for Food Packaging Quality

The equipment utilizes advanced electrochemical and infrared sensors to measure the permeability of packaging materials to gases like oxygen and carbon dioxide. This capability is essential for food packaging analysis, ensuring products maintain freshness by preventing oxidation. Its hardened alloy chamber and microprocessor-based control guarantee durability and consistency throughout repetitive tests.


Streamlined Operation and Customizable Data Analysis

Equipped with automatic operation and a user-friendly LCD display, the system allows operators to conduct tests smoothly with adjustable parameters. The customizable software provides comprehensive data analysis and storage, while real-time and batch data output options enhance flexibility for manufacturers, exporters, and suppliers.


Certified Safety and Environmental Compliance

Safety and reliability are prioritized through built-in visual and audible alarms, automatic power-off, overpressure protection, and compliance with ISO 9001 and CE standards. These features align with international quality norms, supporting user confidence during routine or critical analyses of packaging materials.

FAQ's of Packaging Material Testing to Prevent Food Oxidation:


Q: How does the equipment test packaging material for oxidation prevention?

A: The equipment employs electrochemical and infrared sensors within a controlled chamber to introduce gases such as oxygen, carbon dioxide, and nitrogen. By measuring the permeability and potential for gas leakages, it accurately assesses how well packaging materials protect food products from oxidation.

Q: What types of packaging materials can be tested using this equipment?

A: This machine supports flexible specimen sizes up to 100 x 100 mm and accommodates 1 to 3 samples per test, making it suitable for a wide range of packaging materials like films, foils, and containers commonly used in food packaging.

Q: When should calibration be performed and which methods are available?

A: Calibration should be conducted before starting a test sequence or after significant usage to ensure accuracy. The equipment provides both manual and automatic calibration methods for precise sensor adjustment.

Q: Where can the equipment be installed in a facility, and what are its mounting requirements?

A: This device is designed for benchtop mounting, requiring a stable surface. It needs access to a 220V AC, 50Hz power supply and sufficient workspace to accommodate the chamber and operator comfort.

Q: What is the process for running a test and analyzing results?

A: Users place specimens inside the chamber, select test parameters, and start the automated test via the microprocessor-based control. Results are displayed on the LCD screen, and data can be analyzed with included software, outputting in real-time or batch print formats.

Q: How does using this equipment benefit food exporters and manufacturers?

A: By facilitating accurate, rapid measurement of packaging materials' resistance to oxidation, manufacturers and exporters can ensure product integrity, comply with international standards, and maintain high quality throughout the supply chain.

Q: What safety features are incorporated to protect users and samples?

A: The equipment includes automatic power-off, overpressure protection, and both visual and audible alarms for abnormal test conditions, minimizing risks during operation and protecting both users and specimens.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.