Product Details:

  • Accuracy 0.5% F.S.
  • Measuring Range 0.00110 cm/s
  • Gas Pressure 01 MPa
  • Operating Voltage 220V AC
  • Interface Type USB & RS-232
  • Humidity 099% RH control
  • Equipment Type Diffusion & Permeability Evaluation Instrument
  • Click to View more
X

Evaluation of Diffusion and Permeability Coefficients in Flat Polymer Structures Price And Quantity

  • 50000 USD ($)/Set
  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set

Evaluation of Diffusion and Permeability Coefficients in Flat Polymer Structures Product Specifications

  • Automatic
  • 100 mm x 100 mm
  • 0.001 cm/s
  • 1560C
  • 85 kg
  • Benchtop
  • Automatic with digital control
  • 300 mm
  • < 1 sec
  • 220V / 50Hz
  • Precise humidity and temperature control, high accuracy, data logging
  • 50 mm
  • Laboratory evaluation
  • Up to 6 simultaneously
  • 50 Hz
  • 0.5% F.S.
  • 100 mm
  • 0.01 0.5 mm/min
  • 0.00110 cm/s
  • Multi-sample capability
  • 01 MPa
  • 220V AC
  • 0.00110 cm/s (Diffusion coefficient)
  • 099% RH control
  • USB & RS-232
  • Diffusion & Permeability Evaluation Instrument
  • 1/4 BSP
  • Measurement of diffusion and permeability coefficients in flat polymer structures
  • Digital LCD

Product Description

Product FeaturesNote1

Innovative structure design & upgraded automatic operation

  • Test cells with brand new pop-up drawer type design
  • Automatic specimen clamping with uniform force
  • Components are supplied by global well-known manufacturers, which are reliable and stable in performance
  • Intelligent test mode, one-button test operation (test temperature should be set in advance) and automatic stop
  • Scientific research mode provides more flexible parameter and function settings for analysis of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient

Upgraded testing accuracy and efficiency

  • Imported high precision vacuum sensor for tests of ultra-high barrier property (0.01 0.09 cm3/ m224h0.1MPa) materials with high accuracy and repeatability
  • Imported pneumatic control system with ultra-low failure rate and extremely long service life, which guarantees the seal performance of the whole system
  • Imported high precision vacuum pump improves the evacuation efficiency and generates vacuum up to 0.2Pa
  • The vacuum pump is turned on/off automatically
  • For low and medium barrier property materials, test time is less than 4 hours (including evacuation time)
  • For high barrier property materials, test time is less than 8 hours (including evacuation time)
  • Three independent test cells provide individual test results, specimens can be replaced as desired

Excellent temperature and pressure control technique

  • 360circulation constant temperature technology is applied in the instrument to remain the test temperature fluctuation below 0.05C
  • Labthinks unique pressure compensation technique is used to maintain the stable differential pressure (pressure change is less than 0.2KPa)
  • The pressure of high pressure chamber can be adjusted from 10KPa to 210KPa and maintained precisely

Versatile functions based on standards, customization available

  • Various types of gases are testable: sole gas, mixed gases, poisonous gases, explosive gases and other dangerous gases (customization is required)
  • The humidity of test gas can be adjusted and controlled automatically by the system, without requiring human intervention (customization is required for humidifying device)
  • Labthinks unique data fitting function can provide the test results of gas transmission rate, permeability coefficient, solubility coefficient and diffusion coefficient at extreme temperatures
  • Reference film for fast calibration ensures accurate and universal test data
  • Calibration port for verifying test temperature and pressure
  • Conform to the test standards of differential pressure method

High end, secure and easy-to-use embedded computer controlled system

  • Integrated design of instrument and software minimizes the malfunctions caused by computer virus or faulty operations and ensures the performance of the instrument and data security
  • The instrument can be easily operated with a mouse, a keyboard and a monitor. Windows operation interface for testing operations and displaying data
  • The system is equipped with four USB ports and dual Internet ports for convenient data transmission
  • The instrument meets the requirements of China GMP of pharmaceutical industry (optional)
  • Labthinks unique DataShieldTM system for data management and connecting information management system (optional)

Test Principle

C130H is designed in accordance with differential pressure method. The pre-conditioned specimen is mounted in the gas diffusion cell as to form a sealed barrier between two chambers. The lower-pressure chamber is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber and a constant pressure difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by monitoring the pressure changes in the lower chamber.

Test StandardNote1

ISO 2556, ISO 15105-1, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003

ApplicationsNote1

This instrument is applicable to the determination of gas permeability of:

Basic Applications
  • Films
    Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others
  • Sheeting
    Including engineering plastics, rubber and building materials, e.g. PP, PVC and PVDC
Extended Applications
  • Various Gases
    Test the permeability of various types of gases, e.g. O2, CO2, N2, Air and He
  • Inflammable, Explosive and Poisonous Gases
    Test the permeability of inflammable, explosive and poisonous gases
  • Biodegradable Films
    Test gas permeability of various sorts of biodegradable films, e.g. starch-based biodegradable bags
  • Materials for Aerospace Usage
    This instrument can test the Helium permeability of airship gas bags
  • Paper and Paper Board
    Test gas permeability of paper and paper-plastic composite materials, e.g. aluminized paper for cigarette packages, Tetra Pak sheeting, paper bowls for instant noodles and disposable paper cups
  • Paint Films
    Test gas permeability of substrates coated paint films
  • Glass Fiber Cloth and Paper
    Including glass fiber cloth and paper materials, e.g. Teflon paint cloth, Teflon welding cloth and Teflon silicon rubber cloth
  • Soft Tube Materials for Cosmetics
    Including various types of cosmetic tubes, aluminum-plastic tubes and toothpaste tubes
  • Rubber Sheeting
    Including various sorts of rubber sheeting, e.g. car tires

Technical SpecificationsNote2

Specifications Film Test
Test Range 0.01 50,000 cm3/m224h0.1MPa
Resolution 0.001 cm3/ m224h0.1MPa
Temperature Range 10C 50C (room temperature 23C)
Resolution 0.01C
Temperature Fluctuation 0.05C
Temperature Accuracy 0.3C (calibration port)
Vacuum Resolution 0.01Pa
Vacuum Accuracy Displayed Value 0.2% (1%100% of sensor range)
Vacuum Degree of Test Chamber < 10 Pa
Number of Specimens 3 with independent test results
Customization available for other number of specimens
Specimen Size 97 mm
Test Area 38.48 cm2
Test Gas O2, N2, and CO2 (outside of supply scope)
Humidifying of Test Gas (customization available)
Test Pressure 10KPa 210KPa
Gas Supply Pressure 0.5 Mpa 0.6 Mpa (73psi 87psi )
Port Size 6 mm PU Tubing
Instrument Dimension 710 mm (L) 350 mm (W) 630 mm (H)
Power Supply 220VAC10% 50Hz / 120VAC10% 60Hz
Net Weight 100 kg

Configurations

Standard Configurations
Instrument, Monitor, Keyboard, Mouse, Round Sample Cutter, Vacuum Grease, Fast Quantitative Filter Paper and Vacuum Pump, 6 mm PU tubing (3m)
Optional Parts
GMP Computer System, DataShieldTM Note3, Air Compressor
Note
1. The gas supply port of the instrument is 6 mm PU tubing;
2. Customers need to prepare gas supply.

Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Advanced Sensor Technology

This instrument incorporates a high-sensitivity thermal conductivity sensor, which is integral to obtaining precise diffusion and permeability measurements in polymers. The sensor features rapid response times of less than one second, delivering reliable data essential for critical laboratory evaluations.


Multi-Specimen Testing Efficiency

Supporting up to six simultaneous specimens, this device maximizes laboratory efficiency. With a programmable cycle time (1300 minutes) and test width of 100 mm, it accelerates routine testing while ensuring accurate and repeatable results, enhancing research productivity.


Comprehensive Data Management

Easily store and manage up to 10,000 test records via internal memory, with seamless data export using USB or RS-232 interfaces. The included PC control and analysis software provides straightforward operation, secure logging, and rapid post-test analyses.


Precision Environmental Control

Benefit from automatic digital control of humidity (099% RH), temperature (1560C), and gas pressure (01 MPa) within a stainless steel chamber. Double O-ring seals reinforce reliability, while built-in alarms protect against operational anomalies.

FAQs of Evaluation of Diffusion and Permeability Coefficients in Flat Polymer Structures:


Q: How is the instrument used to evaluate the diffusion and permeability coefficients in flat polymer structures?

A: The instrument employs a high-sensitivity thermal conductivity sensor that continuously measures changes in gas or vapor passing through a flat polymer specimen. Controlled environmental conditions are established within a sealed chamber, and the data is logged and analyzed using the included PC software for precise evaluation of diffusion and permeability coefficients.

Q: What benefits does the internal memory offer for laboratory testing?

A: The internal memory can store up to 10,000 test records, enabling users to conduct extended testing sessions without frequent data transfers. This feature facilitates seamless result tracking and ensures comprehensive record-keeping for compliance and quality assurance.

Q: When should users perform calibration on this equipment?

A: Calibration should be performed during initial setup and periodically as recommended by the manufacturer, especially before critical tests. Both factory and user calibrations are supported to ensure long-term measurement accuracy.

Q: Where can this instrument be used, and who are the ideal users?

A: This diffusion and permeability evaluation instrument is designed for laboratory useparticularly in research, quality control, and materials science departments. It is ideal for producers, researchers, dealers, exporters, and suppliers working with polymer materials.

Q: What is the typical process for conducting a test with this evaluation instrument?

A: Users load up to six polymer specimens into the stainless steel chamber, set the desired temperature, humidity, and pressure parameters, then initiate the test via digital control or connected PC software. The instrument records diffusion and permeability data at programmable intervals, with alarms monitoring for operational anomalies.

Q: How does the programmable cycle time enhance testing flexibility?

A: A programmable cycle time (1300 minutes) allows researchers to run both short and long-duration tests according to specific analytical requirements. This flexibility supports a wide range of polymer structures and helps optimize lab schedules.

Q: What features ensure measurement accuracy and system reliability?

A: The instrument offers 0.5% FS accuracy, resolution of 0.001 cm/s, and an advanced alarm system for over-pressure, temperature, and sensor faults. Its stainless steel chamber and double O-ring seal further ensure durability and operational reliability during testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Packaging Testing Instrument' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.