Call Us
Send Inquiry
Testing instrument for Functionality and Appeal of Cosmetics Packaging

Testing instrument for Functionality and Appeal of Cosmetics Packaging

50000 USD ($)/Set

Product Details:

  • Max Height 400 mm
  • Frequency 50 Hz
  • Operating Voltage 220V AC
  • Test Range 0-500 N
  • Equipment Type Cosmetic Packaging Tester
  • Resolution 0.1 N
  • Humidity 20-80% RH
  • Click to View more
X

Testing instrument for Functionality and Appeal of Cosmetics Packaging Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set

Testing instrument for Functionality and Appeal of Cosmetics Packaging Product Specifications

  • 10-300 mm/min adjustable
  • 0-500 N
  • 50 Hz
  • 400 mm
  • 220V AC
  • 500 N
  • 10-40C
  • 220V AC, 50 Hz
  • Multi-function testing, programmable tests, auto-calibration
  • Cosmetic Packaging Tester
  • 0.1 N
  • 20-80% RH
  • 1 second
  • Supports hardness testing accessories
  • Digital LCD
  • Benchtop
  • USB & RS232
  • Semi-automatic
  • Up to 5 simultaneously
  • 0-500 N
  • Approx. 35 kg
  • Max 200 x 200 mm
  • Standard 8 mm
  • Digital touch panel
  • Functionality and appeal testing of cosmetic packaging
  • 1% of reading
  • 0.4-0.7 MPa
  • Laboratory and industrial quality control
  • Up to 300 mm
  • 0-250 mm

Product Description

Product FeaturesNote1

Accurate Data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01i0.09cm3/ m324h0.1MPa test range.
  • Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
  • Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
  • The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
  • Labthinks unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
  • The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.

High Efficiency

  • Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Medium and low barrier materials, test time <4 hours (including vacuumize time).
  • High barrier materials, test time <4 hours (including vacuumize time).
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
  • Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Tests of hazardous gases such as H2aCH4 are applicable (Customize).

Test Principle

The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.

Standard

ISO 15105-1aISO 2556aGB/T 1038-2000aASTM D1434aJIS K7126-1aYBB 00082003

Applications

Applications
  • Films
    Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C106H
Test range cm3/m224h0.1MPa 0.01i50,000
Resolution cm3/m224h0.1MPa 0.001
Test temperature 15i50i145i60i14Optionali14
Temperature resolution 0.01
Temperature fluctuation 0.15
Test humidity %RHi14Within standard test temperature rangei14 0%i145i902%i14Customizei14
Vacuum Resolution Pa 0.01
Vacuum Accuracy Pa 0.2%i141%-100% of Full Scalei14
Vacuum Degree of Test Chamber Pa 10
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.6i1411.7cm11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 38.48cm2
Test Gas O2aN2aCO2 etc.i14Outside of supply scopei14
Test Pressure 10 kPa210 kPai14Can be set betweeni14
Pressure Fluctuation 0.2 kPa
Gas Pressure 79.7 PSI / 550 kPa
Port Size I6 mm PU tubing
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz/220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, I6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas compressor port of the instrument is I6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Advanced Testing for Packaging Excellence

The CPK-FA300 ensures cosmetics packaging meets demanding industry standards in both function and visual appeal. Its precise digital control and programmable testing enable customizable evaluations tailored to specific requirements. This tester's advanced features, including auto and manual calibration, multi-specimen capacity, and compatibility with a range of packaging materials, make it indispensable for maintaining quality and consistency in cosmetic packaging.


User-Friendly, Safe, and Versatile Operation

Designed for ease of use, the CPK-FA300 incorporates safety features such as overload protection and emergency stop. With a digital touch panel, adjustable test speeds, and noise levels below 60 dB, this benchtop model is suitable for both busy laboratories and industrial quality control departments. Its semi-automatic operation, comprehensive fixture selection, and advanced data management streamline the testing process for users.

FAQ's of Testing instrument for Functionality and Appeal of Cosmetics Packaging:


Q: How does the CPK-FA300 test the functionality of cosmetic packaging?

A: The CPK-FA300 performs tests such as compression, flexural, and hardness evaluations to assess if packaging provides sufficient protection and mechanical integrity. Users can program specific tests using the digital panel and measure responses in real-time with high accuracy and a sampling rate of 1000 Hz.

Q: What materials can be tested with this instrument?

A: This tester is compatible with a wide variety of cosmetic packaging materials, including PET, HDPE, LDPE, glass, and metals, making it suitable for most industry-standard packaging types.

Q: When should I calibrate the CPK-FA300 and how is it done?

A: Calibration should be performed before initial use and at regular intervals as prescribed by your quality management system. The CPK-FA300 features both auto and manual calibration modes, accessible via the digital touch panel, with included calibration weights ensuring accurate setup.

Q: Where can the CPK-FA300 be operated safely?

A: It is designed for indoor, non-corrosive environments with ambient temperature between 10-40C and humidity of 20-80% RH. Its compact benchtop design makes it suitable for laboratories, manufacturing floors, and quality control departments.

Q: What is the process for logging and exporting test data?

A: The instrument internally stores test data, which can be exported to a PC via USB or RS232 interface. Included analysis and reporting software enables comprehensive documentation and review of all test results.

Q: Can the CPK-FA300 test multiple samples at once?

A: Yes, it can test up to five specimens simultaneously thanks to its interchangeable specimen holders, increasing throughput for laboratory and industrial applications.

Q: What are the main benefits of using the CPK-FA300 for cosmetic packaging testing?

A: Key benefits include compliance with international standards (ISO, ASTM, GMP), high measurement accuracy, rapid testing, programmable functions, versatile material compatibility, and straightforward data management-supporting consistent product quality and faster time-to-market.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Packaging Testing Instrument' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)