Call Us
Send Inquiry    Call Me Free
Testing Reveals Oxygen Transmission Rates in Heat Patch Inner Packaging

Testing Reveals Oxygen Transmission Rates in Heat Patch Inner Packaging

50000 USD ($)/Set

Product Details:

  • Measuring Range 0.01 3000 cc/mday
  • Accuracy 2% of reading
  • Mounting Type Tabletop
  • Equipment Type Oxygen Transmission Rate Tester
  • Frequency 50 Hz
  • Operating Voltage 220 V AC
  • Display Type Touchscreen digital display
  • Click to View more
X

Testing Reveals Oxygen Transmission Rates in Heat Patch Inner Packaging Price And Quantity

  • 50000 USD ($)/Set
  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • Stainless steel, anti-corrosion
  • Online technical support
  • Quick swap design
  • Up to 100,000 test results
  • Integrated statistical data analysis and remote monitoring
  • 520 mm × 470 mm × 400 mm
  • CSV, PDF
  • RoHS, CE certified
  • 15°C to 35°C
  • Electrochemical oxygen sensor
  • Multi-language interface
  • Multi-point automatic calibration
  • Over-pressure and temperature alarms

Testing Reveals Oxygen Transmission Rates in Heat Patch Inner Packaging Product Specifications

  • 115 mm 70 mm
  • Laboratory analysis of packaging films
  • 0.1 - 500 mm/min adjustable
  • Multi-channel simultaneous testing
  • Fully automatic
  • < 10 s
  • RS232/USB
  • High accuracy, automatic temperature and humidity control, real-time data acquisition
  • Testing oxygen permeability of heat patch inner packaging
  • 65 kg
  • 80 mm
  • 6 mm quick-connect
  • 220 V AC
  • Touchscreen digital display
  • 0.6 MPa
  • Tabletop
  • 50 Hz
  • Oxygen Transmission Rate Tester
  • 0.01 3000 cc/mday
  • 2% of reading
  • 600 mm
  • 3 specimens simultaneously
  • 0.001 cc/mday
  • AC 220V 10% 50Hz
  • Applicable to soft & rigid packaging
  • 15-50C adjustable
  • Microcomputer automatic control
  • 115 mm specimen
  • 0.01 3000 cc/mday
  • 10-98% RH adjustable
  • Stainless steel, anti-corrosion
  • Online technical support
  • Quick swap design
  • Up to 100,000 test results
  • Integrated statistical data analysis and remote monitoring
  • 520 mm × 470 mm × 400 mm
  • CSV, PDF
  • RoHS, CE certified
  • 15°C to 35°C
  • Electrochemical oxygen sensor
  • Multi-language interface
  • Multi-point automatic calibration
  • Over-pressure and temperature alarms

Product Description

Product FeaturesNote1

Accurate Data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01i0.09cm3/ m324h0.1MPa test range.
  • Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
  • Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
  • The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
  • Labthinks unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
  • The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.

High Efficiency

  • Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Medium and low barrier materials, test time <4 hours (including vacuumize time).
  • High barrier materials, test time <4 hours (including vacuumize time).
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
  • Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Tests of hazardous gases such as H2aCH4 are applicable (Customize).

Test Principle

The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.

Standard

ISO 15105-1aISO 2556aGB/T 1038-2000aASTM D1434aJIS K7126-1aYBB 00082003

Applications

Applications
  • Films
    Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C106H
Test range cm3/m224h0.1MPa 0.01i50,000
Resolution cm3/m224h0.1MPa 0.001
Test temperature 15i50i145i60i14Optionali14
Temperature resolution 0.01
Temperature fluctuation 0.15
Test humidity %RHi14Within standard test temperature rangei14 0%i145i902%i14Customizei14
Vacuum Resolution Pa 0.01
Vacuum Accuracy Pa 0.2%i141%-100% of Full Scalei14
Vacuum Degree of Test Chamber Pa 10
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6 x 4.6i1411.7cm11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 38.48cm2
Test Gas O2aN2aCO2 etc.i14Outside of supply scopei14
Test Pressure 10 kPa210 kPai14Can be set betweeni14
Pressure Fluctuation 0.2 kPa
Gas Pressure 79.7 PSI / 550 kPa
Port Size I6 mm PU tubing
Instrument Dimension 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Power Supply 120VAC10% 60Hz/220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, I6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas compressor port of the instrument is I6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



Advanced Sensor Technology for Reliable Testing

This OTR tester employs a high-sensitivity electrochemical oxygen sensor, enabling fast and accurate oxygen permeability analysis for heat patch packaging. The multi-point automatic calibration ensures consistent measurement accuracy, making it indispensable for quality control in manufacturing and research environments.


User-Friendly Design and Versatile Interface

With an intuitive touchscreen digital display and multi-language interface, this instrument simplifies operation for users worldwide. Quick swap sample loading, microcomputer control, and remote monitoring capabilities streamline the testing process and maximize laboratory efficiency.


Comprehensive Environmental Adaptability

The stainless steel anti-corrosion testing chamber, adjustable temperature (15-50C), and humidity (10-98% RH) controls make this device suitable for a wide range of laboratory conditions. Compliance with RoHS and CE standards guarantees reliable, safe use during routine or demanding investigations.

FAQ's of Testing Reveals Oxygen Transmission Rates in Heat Patch Inner Packaging:


Q: How does the Oxygen Transmission Rate Tester ensure accurate measurements?

A: The tester utilizes an electrochemical oxygen sensor and multi-point automatic calibration to provide precise readings. Combined with automatic temperature and humidity control, these features guarantee high data accuracy with a margin of 2% of the reading.

Q: What is the process for testing oxygen permeability in heat patch inner packaging?

A: Simply load up to three specimens using the quick swap design, set the desired test conditions on the touchscreen interface, and initiate the test. Results are displayed in real time, and can be exported in CSV or PDF formats for further analysis or record-keeping.

Q: When should I use the OTR tester for my packaging materials?

A: This device is ideal during R&D, product validation, and routine quality control phases to ensure packaging films meet oxygen barrier requirements, thus protecting product freshness and extending shelf life.

Q: Where can this tester be used effectively?

A: The tabletop unit is designed for laboratory environments in packaging manufacturing, quality control labs, and research centers, supporting global industries with multi-language support and compliance certifications.

Q: What are the benefits of using this fully automatic OTR tester?

A: Key advantages include high accuracy, rapid data acquisition, large memory capacity, integrated statistical analysis, remote monitoring, and enhanced safety with over-pressure and temperature alarms. The system's automation streamlines workflow and improves testing consistency.

Q: How is technical support provided for this equipment?

A: Comprehensive online technical support is available to assist with installation, troubleshooting, and optimal usage, ensuring minimal downtime and smooth integration into laboratory operations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Gas Permeability Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.