Product Description
Product FeaturesNote1
Ten Test Modes to Meet Various Testing Demands
- Ten independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, puncture test of rubber closure and puncture retention force test, etc. at users choice
- The instrument supports bidirectional testing modes, which can be used for puncture test of rubber closure and breaking force test of ampoule and test speed can be adjusted freely
- Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users
Excellent Testing Mechanism & Improved Test Accuracy
- Force measuring system is supplied by top global supplier, ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
- Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
- Global renowned brand pneumatic control system supports pneumatic specimen clamping, avoids the specimen slipping and guarantees the accuracy of test data
High-end, Secure and Easy-to-Use Embedded Computer-controlled System
- The instrument is integrated with software requiring no external computer
- The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
- Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
- The instrument is equipped with USB ports and Internet ports for convenient data transmission.
- Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.
Test StandardNote1
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
C610M is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:
| Basic Applications |
|
|
- Test of Tensile Strength and Elongation Rate
|
- Test of Tensile Strength at Break
|
|
|
|
|
|
|
|
|
- Tensile Strength Test at Defined Elongation
|
Extended Applications (Additional Accessories Required) |
- Puncture Test of Hypodermic Needles in Artificial Skin
|
|
- Puncture Test of Infusion Bags
|
- Puncture/Pullout Test of Flexible Rubber Closures
|
- Opening Resistance Test of Combined Covers
|
- Tear Test of ZD - Type Caps
|
- Opening Force Test of Oral Liquid Caps
|
- Puncture/Pullout Test of Oral Liquid Caps
|
- 90 Degree Pullout Test of Infusion Bag Caps
|
- Pullout Test of Infusion Bag Caps
|
- 23 Degree Pullout Test of Bottle Caps
|
- Puncture/Pullout Test of Bottle Caps or Rubber Closures
|
- 90 Degree Peel Test of Adhesive Tapes
|
- Tear Resistance Test of Adhesive Binding Books
|
- 90 Degree Peel Test of Water-soluble Plasters
|
- Tear Resistance Test of Adhesives
|
- Adhesive Strength Test (soft)
|
- Adhesive Strength Test (hard)
|
- Peel Test of Flexible Tube Caps
|
- Removal Force of Pipes and Pipe Joints
|
- Pullout Test of Cosmetic Brush Hair
|
- Pullout Test of Tooth Brush Hair
|
- Tensile Strength of Ropes at Break
|
- Opening Force Test of Jelly Cups and Yogurt Cups
|
|
|
- Pullout Test of Rubber Stoppers
|
- 45 Degree Peel Test of Bottle Membranes
|
- Tensile Strength of Sealing Bags
|
- Peel Test of Magnetic Cores
|
- 90 Degree Peel Test of Magnetic Cards
|
- Tear Resistance of Heat Sealing Films
|
- Separating Force of Protection Films
|
- Peel Test of Release Paper
|
- Tear Test Using Trouser Method
|
- Unwrapping Force of Adhesive Tapes
|
- Compressive Resistance of Plastic Bottles
|
|
|
- 135 Degree Peel Test of Plugs
|
- Peeling Grips of Floating Rollers
|
|
|
|
|
|
|
- Tensile Strength of Contact Lenses at Break
|
- Compression Resistance of Jelly Cups
|
- Compression Resistance of Package
|
- Compression Resistance of Sponge
|
|
Technical Specifications
| Specifications |
C610M Auto Tensile Tester |
| Load Cell Capacity |
500 N (standard) 50 N, 100 N, 250 N, 1000 N (optional) 5N (Customization available) |
| Accuracy |
0.5% of indicated value (2%FS 100%FS) 0.01%FS (0% 2%FS) |
| Resolution |
0.001 N |
| Test Speed |
0500 mm/min |
| Speed Accuracy |
0.5% of indicated value |
| Number of Specimens |
1 |
| Specimen Width |
30 mm (Standard Grip) |
| 50 mm (Optional Grip) |
| Clamping Way |
Pneumatic Specimen Clamp |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 MPai1472.5psii101.5psii14 |
| Stroke |
950 mm (customization available for 1200mm) |
| Instrument Dimension |
450 mm (L) x 450 mm (W) x 1410 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
95 kg |
Configurations
- Standard Configurations
- Instrument (with embedded software), LCD Monitor, Keyboard, Mouse, Pneumatic Sample Girps
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Air Compressor
- Note
- 1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Advanced Ampoule Testing TechnologyOur Ampoule Bottle Quality Control Tester leverages a precision load cell for highly accurate mechanical strength measurement, ensuring product reliability. Its user-friendly interface, combined with Windows-compatible analysis software, simplifies operation while allowing tailored test parameters across a 0 - 300 N force range.
Safety and Compliance AssuredConstructed from stainless steel and reinforced ABS, the tester adheres to ISO 9187, USP, and GMP standards. Safety features include an emergency stop button, sensor overload protection, and visual/audible alarms on test failure, making it ideal for certified testing labs and quality assurance in manufacturing.
Efficient Data Management and ReportingWith capacity to store up to 500 records and export results in CSV or printable formats, data traceability and analysis become effortless. The digital LCD displays results in real time, while USB/RS232 interfaces facilitate fast data transfer and integration into your lab's systems.
FAQ's of Ampoule Bottle Quality Control Testing Ensures Product Integrity:
Q: How does the Ampoule Bottle Quality Control Tester assess product integrity?
A: The tester measures the mechanical strength, burst, leak, and breakage resistance of ampoule bottles using a precision load cell. By applying controlled force, it evaluates whether the specimen meets critical integrity standards, ensuring reliable drug containment and delivery.
Q: What is the process for conducting a quality control test on ampoules?
A: Operators select the desired test method and set the duration (between 1 and 30 minutes), place 1-10 ampoules on the tester, and initiate the process. The machine automatically performs the test, records data, and provides real-time results on the digital LCD.
Q: When should manufacturers use this testing equipment?
A: This tester is best employed during production line sampling, final product quality assurance, or incoming materials inspection to consistently ensure that ampoules conform to safety, strength, and compliance requirements before market release.
Q: Where can this tester be implemented in a pharmaceutical facility?
A: Designed for tabletop mounting, the tester is suitable for quality control laboratories, manufacturing lines, or R&D departments in pharmaceutical, medical, and glass packaging facilities.
Q: How is calibration maintained for accurate results?
A: The machine supports both automatic and manual calibration, guaranteeing accurate measurements. Regular calibration should be scheduled in accordance with operational protocols to uphold precision and compliance.
Q: What are the key benefits of using this tester?
A: This tester enhances product safety and compliance, streamlines data output (CSV/printable reports), improves testing efficiency with simultaneous ampoule analysis, and reduces risk through built-in overload protection and safety sensors.
Q: What types and sizes of ampoule bottles can be tested?
A: It accommodates standard ampoule sizes (2 ml, 5 ml, 10 ml, 20 ml) and allows for custom samples, testing up to 10 specimens at once with widths up to 80 mm and test ranges between 0-300 N.