Product Details:

  • Hardness 70 HRB
  • Response Time 1 s
  • Power Supply AC 220V/50Hz
  • Port Size 6 mm air fitting
  • Operating Voltage 220V
  • Humidity 20% - 80% RH
  • Gas Pressure 0.6 MPa
  • Click to View more
X

Off-line Thickness Measurement for PE film and aluminum foil sheets Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 80.0 USD ($)/Set
  • 1 Set

Off-line Thickness Measurement for PE film and aluminum foil sheets Product Specifications

  • 5-150 mm/min adjustable
  • 200 mm
  • Up to 700 mm width x 200 mm length
  • 50 Hz
  • Semi-Automatic
  • 1
  • 0.001 mm
  • 10C 40C
  • Automatic data saving, high accuracy, easy calibration, programmable test parameters
  • 75 kg
  • Benchtop
  • Thickness measurement for PE film and aluminum foil sheets
  • Max 200 mm
  • 0.001 mm
  • 1 s
  • 70 HRB
  • 6 mm air fitting
  • AC 220V/50Hz
  • PLC Controlled
  • 20% - 80% RH
  • 220V
  • 0.6 MPa
  • 200 samples/day
  • RS232/USB
  • Up to 700 mm
  • 0-2 mm
  • Digital LCD
  • Laboratory or Quality Inspection
  • 0.001 mm to 2 mm
  • Off-line Thickness Measurement System

Product Description

Features

Professional

With innovative research and development, Labthink C640 Thickness Tester uses high precision displacement sensor, supported by scientific structure and professional control technology, which makes C640 greatly improved in stability, repeatabilityNote1 and accuracy.

  • The instrument conforms to standards for mechanical contact method. The pressure foot can be lifted and lowered automatically, which can minimize the errors caused by human operation.
  • Contacting time and test speed can be set as required. Customization is available for multiple contact areas and pressures, which can meet the requirements for various test conditions.
  • Manual and automatic test modes can be selected by the users
  • Calibration of multiple points can improve the linearity of the whole test range, which ensures the accuracy of measured results.
  • Standard gauge block is available for fast calibration

High Efficiency

The instrument is featured with high efficiency and automatic design of structure, which minimize the human operation in measuring process. Intelligent controlling and data processing functions make it easy and reliable for test operation and data processing.

  • Parameter program function enables the user to save all test parameters in a file so that those parameters can be applied directly for the same tests next time, which can help the user save time and minimize the error when inputting parameters manually.
  • Test results include maximum value, minimum value, average value and standard variation, which can be displayed to the user directly.
  • Result comparison function can help the user in evaluation of results.
  • Auto sampling function (optional), feeding space, feeding speed, measure points can be set as required, which ensures the accuracy of multiple successive points measurement.

Intelligent

The instrument is embedded with Labthinks latest operating software, which is featured with user-friendly interface, intelligent data processing, strict user management and secure data storage. It also supports Labthink exclusive DataShieldTM (Optional) which provides the users with safe and reliable management of test data and test reports.

  • Test data can be displayed in various forms including curves and data list
  • Test data will be saved and encrypted in a unique way so that all the test information will be saved securely and reliably and protected from being tampered
  • Various forms of test data can be searched, exported and printed out

Note: The described features should be in line with Table 1: Test Parameters.
Note1: The Repeatability refers to the repeatability within the test range.

Test Principle

The pre-conditioned specimen is placed on a flat test plane, the pressure foot which is paralleled to the test plane will drop down on the upper surface of the specimen with certain pressure applied on. The displacement sensor with the pressure foot will detect the space between the upper and lower surface of the specimen, which is the thickness of the specimen.

Test Standards

ISO 4593, ISO 534, ASTM D6988, ASTM F2251, GB/T 6672, GB/T 451.3, TAPPI T411, BS 2782-6, DIN 53370, ISO 3034, ISO 12625-3, ISO 5084, ASTM D374, ASTM D1777, ASTM D3652, GB/T 6547, GB/T 24218.2, FEFCO No 3, EN 1942, JIS K6250, JIS K6783, JIS Z1702

Note: The described test standards should be in line with Table 1: Test Parameters.

Applications

Basic Applications
  • Films and Sheeting
    Thickness measurement of various plastic films, sheeting, and diaphragms, etc.
  • Paper
    Thickness measurement of various paper, paper board and composite paper board, etc.
Extended Applications
  • Metal Pieces & Silicon Wafers
    Thickness measurement of silicon wafers, foils and various metal pieces, etc.
  • Corrugated Paperboard
    Thickness measurement of corrugated paperboard
  • Textiles
    Thickness measurement of textiles including woven fabrics, knitted fabrics, coated fabrics
  • Non-woven Fabrics
    Thickness measurement of non-woven fabrics e.g. baby diapers, sanitary napkins and medical masks, etc.
  • Other Materials
    Thickness measurement of solid insulation materials, adhesive tapes, earthwork synthetic materials and rubbers, etc.

Technical Specifications

Table 1: Test Parameters Note1

Parameter Model C640M C640H
Test Range (Standard) mm 0 2 0 2
Resolution m 0.1 0.1
RepeatabilityNote3 m 0.8 0.4
Test Range (Optional 1) mm 0 6 0 6
Test Range (Optional 2) mm 0 12 0 12
Feeding Space mm 0 1000 (Adjustable)
Feeding Speed mm/s 1.5 80 (Adjustable)
Additional Functions Auto Sampler Optional Optional
DataShieldTM Note2
Optional Optional

Table 2: Technical Specifications

Measuring Method Mechanical Contact Method
Test Pressure & Contact AreaNote3 Film: 17.51 KPa, 50 mm2
Paper: 1001 KPa (Standard) / 501kPa (Optional), 200mm2
Instrument Dimension 370 mm (L) x 350 mm (W) x 410 mm (H)
Net Weight 26kg

Note1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions. For extended applications, customization is available to meet the special testing requirements.
Note2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note3: Test pressure and contact area can be selected for paper or film. There are two options for test pressure for paper, i.e. 100kPa (standard) and 50kPa(optional). For other test pressure and contact area or curved pressure foot, customizations are available.



High-Precision Thickness Measurement

Ensure the quality of PE film and aluminum foil sheets with the high-accuracy (0.001 mm) off-line thickness measurement system. The instrument leverages a contact probe micrometric approach, engineered for both reliability and repeatability in laboratory and quality control applications.


Robust Construction and Reliable Operation

Engineered with an aluminum alloy body, the device is designed for durability and stable measurements. The anti-static base and alignment guides guarantee consistent sample positioning, while the system's overload protection and emergency stop provide user safety during operation.


Smart Software and Data Management

Streamline workflow using the included dedicated analysis software. With automatic data saving and export via USB or PC, results are easily archived or shared. Programmable test parameters and a digital LCD display provide flexibility and clear results for your measurement processes.

FAQ's of Off-line Thickness Measurement for PE film and aluminum foil sheets:


Q: How does the contact probe micrometric measurement work for thickness testing?

A: The system uses a precision contact probe to measure the thickness of PE film and aluminum foil sheets while the sample rests on an anti-static base. The probe moves across the sample, capturing highly accurate thickness values (0.001 mm) with each measurement.

Q: What are the calibration options and when should I calibrate the device?

A: Both automatic and manual calibration options are provided. Calibration should be performed initially during setup, after any maintenance, or when measurement accuracy needs to be verified, in line with your laboratory's standard procedures.

Q: Where can this thickness measurement equipment be installed and used?

A: This benchtop system is designed for use in indoor, dust-free laboratory or quality inspection environments. On-site installation and training services are available to help ensure proper setup and user proficiency.

Q: What is the process for measuring samples and how many can be tested per day?

A: The system accommodates specimens up to 700 mm width by 200 mm length, allowing up to 200 samples per day. Simply align the sample using the guides, initiate the measurement via the digital LCD or control software, and export the results upon completion.

Q: What are the advantages of using this system for thickness measurement?

A: Benefits include high-precision measurements, automatic and manual calibration, automatic data saving, easy integration with laboratory systems via USB or RS232, programmable test parameters, and a robust, low-maintenance design.

Q: What safety and compliance standards does the equipment meet?

A: The device is equipped with overload protection, an emergency stop, and is certified to both ISO and CE standards, ensuring operator safety and regulatory compliance throughout use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Thickness Testers' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.