Call Us
Send Inquiry    Call Me Free
Detecting Leaks in Pharmaceutical Packaging

Detecting Leaks in Pharmaceutical Packaging

50000 USD ($)/Set

Product Details:

  • Power Supply AC 220V, 50Hz
  • Equipment Type Leak Tester for Pharmaceutical Packaging
  • Measuring Range 0-600 kPa
  • Features Touch screen control, programmable test duration, automatic data storage
  • Accuracy 1% FS
  • Interface Type RS232/USB
  • Gas Pressure 0.4 MPa - 0.7 MPa
  • Click to View more
X

Detecting Leaks in Pharmaceutical Packaging Price And Quantity

  • 1 Set
  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set

Detecting Leaks in Pharmaceutical Packaging Product Specifications

  • AC 220V 10%, 50Hz
  • 6 mm (Air Inlet)
  • 50Hz
  • LCD Digital Display
  • 150 mm (Specimen Chamber Height)
  • Leak detection and quality control
  • Up to 300 mm width
  • 40 kg
  • 20% RH - 70% RH
  • Benchtop
  • 1 to 3 (Simultaneous test possible)
  • Microcomputer control
  • Semi-Automatic
  • Detecting leaks in pharmaceutical packaging (blister packs, strips, pouches, etc.)
  • 0.4 MPa - 0.7 MPa
  • <2 seconds
  • Varies as per specimen
  • 0.1 kPa
  • 15C - 35C
  • 0 - 600 kPa
  • AC 220V, 50Hz
  • Adjustable, Max 300 mm
  • 300 mm
  • Leak Tester for Pharmaceutical Packaging
  • Touch screen control, programmable test duration, automatic data storage
  • 0-600 kPa
  • 1% FS
  • Adjustable 10-120 cycles/min
  • RS232/USB

Product Description

Featuresnote1

Batch Testing

  • Equipped with fully-automatic gravity fed sample feeder, which is Labthinks latest scientific and technological achievement that can facilitate continuous testing of 20 to 120 samples.
  • A & B dual-channel design can test samples of two different specifications simultaneously.
  • The target vacuum degree can be set by the operator to meet testing requirements of different samples.
  • Dual methods of vacuum decay and pressure decay provide the flexibility to accommodate various types of package samples.

Precise Data

  • Advanced pressure detection technology, using world renowned components for data stability which is not affected by ambient environment.
  • Advanced microflow automatic flow control technology that can accurately simulate different sizes of leakage holes without manual adjustment.
  • Both the differential pressure transducer and flow meter are traceable to NIST.
  • The system can achieve a higher test repeatability of 1um.

Intelligent Control

  • 15.6" embedded touch tablet computer with Windows OS.
  • New longitudinal interface layout, and easy to use graphic user interface.
  • Automatic alarm, automatic capture, automatic collection of unqualified samples.
  • The pressure curve is displayed in real time, and the test results are counted automatically.
  • Leakage rates are calculated automatically.
  • The system is equipped with various sensors as intelligent reminders for safer operation and control.
  • Universal printer can be connected for test results output.
  • The system features embedded with USB and network ports to facilitate the external access and data transmission of the system, which can be upgraded remotely

Security Compliance

  • Verified by compensation and calibration methods.
  • The leak tester meets GMP requirements for data traceability and meets the needs of the pharmaceutical industry.
  • User operation permission is managed at multiple levels, and the permission content can be configured on demand.
  • Electronic signature is designed according to the standard requirements of 21 CFR Part11.

Test Principle

The sample is placed in the sample feeder and automatically delivered into the test cell. The leak rate and other results can be calculated and obtained by analyzing pressure changes measured by the sensor.

Reference Standards

ASTM F2338, YY-T 0681.18, and USP<1207>

Applications

Basic Applications Vials Various vial sealing test.
Extended Applications Ampoule Various ampoule bottle sealing tests.
Cartridge Bottles Various cartridge bottle sealing tests.
Injection bottles Various injection bottles sealing test.

Technical Parameters

Table 1: Test Parameters Note2

ParameterModel C690H
Testing Range um(Reference aperture size USP1207) 3i8igreat leakage
Detection Lower Limit um 3
Resolution um 0.1
Repeatability um 1
Pressure Range kPa -100i0ii14100
Extended Functions 21 CFR Part11 Optional
GMP computer system requirements Optional

Table 2: Technical Specifications

Testing Cell 1 set for A group and 1 set for B group
Sample Feeder 1 set for A group and 1 set for B group
Sample Size I45 mm80mmNote3
Sample Quantity 20120 pieces
Gas Specifications Compressed Air (Gas source is provided by the user)
Gas Source Pressure 40.6 PSI / 500 kPa
Port Size I6 mm Polyurethane tube
Dimensions 33.4 H x 19.6 W x 28.7 D (85cm 50cm 73cm)
Power 120VAC10% 60Hz / 220VAC10% 50Hzi14select one from the twoi14
Net weight 209Lbs (95kg)

Product Configuration

Standard Configuration Mainframe, embedded tablet computer, software, flow meter, European vacuum pump, I6 mm polyurethane tube
Customization Test cell and sample feeder of group A, test cell and sample feeder of group B, negative standard reference sample and positive standard reference sample designed according to sample specifications
Optional Parts GMP computer system requirements, 21 CFR Part11, air compressor, IQ/OQ/PQ documents

Note 1: The described product characteristics are subject to the specific annotation of the "Technical Parameters" table.
Note 2: The parameters in the table are measured in the Labthink laboratory by professional operators according to the requirements and conditions of the relevant laboratory environmental standards.
Note 3: Group C test cell can be customized for samples beyond the "Sample Size", but the lower detection limit and test range will change according to the sample size, and the actual delivery shall prevail.



Efficient and Reliable Leak Testing

Designed specifically for pharmaceutical packing, this leak tester ensures products meet stringent standards by detecting even minor leaks. With a measuring range up to 600 kPa and accuracy of 1% FS, users benefit from rapid, reliable quality assessments. The device accommodates up to three specimens simultaneously, streamlining batch inspections for manufacturers.


User-Friendly Controls and Data Management

Operated via an easy-to-use LCD touch screen with intuitive microcomputer controls, the tester allows operators to adjust stroke, test duration, and speed. All measurement data is automatically stored and can be seamlessly exported for in-depth analysis through RS232/USB connectivity and compatible PC software, enhancing traceability and regulatory compliance.


Compliant and Safe by Design

Constructed from durable stainless steel, the tester is built for long-term, safe operation. It includes multiple safety features, such as automatic pressure relief and over-pressure protection, to safeguard users and specimens. Furthermore, an audio-visual alarm system promptly notifies operators of any detected leakage, ensuring immediate corrective action.

FAQ's of Detecting Leaks in Pharmaceutical Packaging:


Q: How does the leak tester detect leaks in pharmaceutical packaging?

A: The leak tester uses vacuum decay and pressure hold methods while applying compressed clean air to the packaging. Microcomputer controls monitor minute pressure changes within a sealed stainless steel chamber, enabling quick detection of leaks in blister packs, strips, or pouches.

Q: What types of pharmaceutical packaging can be tested with this device?

A: This leak tester is suitable for a range of pharmaceutical packaging, including blister packs, strips, pouches, and similar sealed products, accommodating specimen widths up to 300 mm and chamber heights up to 150 mm.

Q: When should leak testing be performed in pharmaceutical manufacturing?

A: Leak testing should be part of quality control during final product inspection, pre- or post-packaging, or whenever there is a need to verify package integrity in compliance with regulatory standards such as USP, ASTM, and ISO 11607.

Q: Where can this leak tester be installed, and what are the installation requirements?

A: Designed as a benchtop unit, the tester can be placed in laboratory or production areas with access to standard AC 220V, 50Hz power supply and compressed air (0.4 MPa - 0.7 MPa). Ambient temperature should be between 15C and 35C, with humidity of 20%-70% RH for optimal performance.

Q: What is the process for operating the leak tester?

A: After placing up to three specimens in the chamber, operators select test parameters (duration, stroke, speed) via the touch screen. The machine runs the programmed test cycle, detects leaks via pressure variation, and provides results on the LCD display, with data stored for later analysis.

Q: How does using this leak tester benefit pharmaceutical manufacturers?

A: Manufacturers gain improved quality control, reduced risk of product recalls, and enhanced regulatory compliance. The device's high accuracy, adjustable parameters, and automation grade streamline workflow, while comprehensive safety and alarm features safeguard operations and product quality.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Package Leak Tester' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.