Product Description
Product FeaturesNote1
Infrared Moisture Sensor
- The Labthink patented technology infrared moisture sensor can obtain lower test limit.
- Designed according to ASTM F1249.
- Long service life, non-consumable.
- It has the functions of over limit alarm and automatic protection.
Accurate Data
- Using 360 air circulation constant temperature technology, the temperature stability is better.
- Equipped with high-precision temperature and humidity sensor for real-time monitoring and recording temperature and humidity changes.
- In the test process, the automatic control of flow, temperature and relative humidity is realized, and the accuracy is higher.
- It can achieve higher test repeatability of 0.005 g / (m2day) .
High Efficient Three-chamber
- Independent three sets of 50cm2 standard area test chamber, in line with the standard requirements of parallel sample detection.
- Three samples are tested at the same time under the same condition, and the data are independent of each other.
- In the same test cycle, the testing number of samples completed increased from 2 to 3.
- Automatic sample clamping, saving time and effort, realizing consistent clamping force and better sealing.
Intelligent Control
- The 12 Inch Touch panel of Windows system is used to control, which is more convenient.
- Automatic mode: input the test temperature and humidity, click one key to start the automatic test.
- New drawer type test chamber, one key automatic in and out, sound and light reminder.
Safe and Reliable
- Safe running: the unique high-end industrial computer of Labthink is embedded to eliminate the system failure caused by computer virus, and ensure the operation reliability and data storage security.
- Safe operation: equipped with optical and other intelligent sensors, sound and light alarm and other intelligent alarms to ensure the safety of operation.
- Safe Performance: the instruments are made of world famous brand components, stable and reliable.
Powerful Functions
- Professional test mode provides flexible and rich control functions to meet the needs for scientific research.
- Provide water vapor transmission curve, water vapor transmission coefficient curve, temperature curve, humidity curve.
- Ultra wide test range, meet the barrier test of various materials. (Customized)
- Ultra wide temperature range to meet the permeability tests at different temperatures. (Customized)
Testing Principle
The pre-treated sample is clamped between the test chambers, the nitrogen with stable relative humidity flows on one side of the film, and the dry nitrogen flows on the other side of the film; due to the existence of humidity difference, water vapor will diffuse from the high humidity side through the film to the low humidity side; on the low humidity side, the water vapor is carried to the infrared water sensor by the flowing dry nitrogen, and different water vapor is generated. The concentration produces different light signals, and the concentration value is obtained through analysis and calculation, and then the water vapor transmission rate of the sample is calculated.
Reference Standards
ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015
Test Applications
| Applications |
- Films
The water vapor transmission rate tests of various plastic film, paper plastic composite film, co-extrusion film, aluminum plating film, aluminum foil composite film, glass fiber aluminum foil paper composite film and other film materials.
|
- Sheet
The water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.
|
Technical Parameters
Table 1: Test Parameters Note2
| Parameters/Model |
C303H |
| Test Scope |
g/(m2day) (standard area 50cm2) |
0.005i40 (standard) 0.005100i14optionali14 |
| g/(m2day) (MASK area 5cm2) |
0.05400 (optional) |
| g/(m2day) (MASK area 1cm2) |
0.252000 (optional) |
| Resolution |
g/(m2day) |
0.0001 |
| Repeatability |
g/(m2day) |
0.005 or2%, whichever is greater |
| Temperature Range |
|
15i50 560 (customized) |
| Temperature Fluctuation |
|
0.05 |
| Humidity Range |
%Rh (within standard temperature range) |
5i901% |
| Extended Functions |
DataShieldTM Data Shield Note 3 |
Optional |
| GMP Computer System Requirements |
Optional |
| CFR21Part11 |
Optional |
Table 2: Technical Specifications
| Test Chamber |
3 sets |
| Sample Size |
4.4 x 4.4i1411.2cm11.2cmi14 |
| Sample Thickness |
120 Mili143mmi14 |
| Standard Test Area |
50cm2 |
| Carrier Gas Specification |
99.999% high purity nitrogen (gas source is prepared by the user) |
| Air Source Pressure |
40.6 PSI / 280 kPa |
| Interface Size |
1 / 8 "metal tube |
| Dimensions |
23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm) |
| Power Supply |
120VAC 10% 60Hz / 220VAC 10% 50Hz |
| Net Weight |
220Lbsi14100kgi14 |
Table 3: Product Configuration
| Standard Configuration |
Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm |
| Options |
Air compressor, CFR21Part11, GMP computer system requirements, DataShieldTM Data Shield Notes3 |
| Note |
The compressed air inlet of the machine is I 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the user. |
Note 1: the product features are subject to the specific notes in the "Technical Parameters" table.
Note 2: the parameters in the table are measured by professional operators in Labthink laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield system provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase it separately according to the usage.
High-Precision Water Vapor Transmission TestingLabthink's ASTM E96 tester is engineered for precision and versatility in measuring water vapor transmission rates. Conforming to rigorous standards, it accommodates diverse materials and offers programmable test conditions, including temperature and humidity control up to 100% RH. With automatic measurement, software-based data analysis, and multi-station capability, laboratories can optimize testing workflows, ensuring reproducible and reliable results.
Advanced Software Integration and Data ManagementThe tester's robust PC software suite facilitates seamless report output, graph plotting, and historical data queries. Real-time monitoring keeps users updated on test progress and environmental conditions, while user-friendly features support automatic calculations and customizable languages. Data is easily exported for in-depth analysis, enhancing traceability and documentation in laboratory settings.
FAQ's of Labthink ASTM E96 Materials Water Vapor Transmission Testers:
Q: How does the Labthink ASTM E96 tester measure water vapor transmission?
A: This equipment utilizes both the desiccant (dry cup) and water (wet cup) methods specified by ASTM E96 to measure the water vapor transmission rate (WVTR) of films, laminates, and various barrier materials. Samples are sealed over trays containing desiccant or water, and the change in sample mass is monitored in controlled ambient conditions to determine WVTR.
Q: What materials can be tested with this system?
A: The tester is compatible with plastic films, coated paper, barrier materials, membranes, packaging materials, and textiles. Each specimen is prepared using a round cutter (typically 74 mm diameter), making it suitable for most industry-standard applications.
Q: When should calibration and maintenance be performed?
A: Regular calibration is recommended using standard calibration dishes and software-based correction tools to ensure ongoing test accuracy. Maintenance is minimal due to durable tray materials (aluminum alloy or stainless steel) and built-in overload protection features, but periodic checks are advised.
Q: Where is this tester best utilized?
A: The instrument is designed for benchtop operation in laboratory, quality control room, and research and development settings, especially within packaging and materials industries requiring compliance with ASTM E96.
Q: What are the main benefits of using this tester?
A: Key benefits include high measurement accuracy (0.01 g/m224h or better), multi-station testing for increased throughput, programmable test timing up to 99 hours, user-adjustable environmental controls, and comprehensive PC software for enhanced data analysis and reporting.
Q: How is the testing process carried out?
A: Samples are cut to the appropriate size using a standard cutter, placed over trays, and the desired test method (dry or wet cup) is selected via software controls. Ambient conditions such as temperature and humidity are set, and the system automatically manages, monitors, and calculates WVTR, providing digital results and graphical reports.
Q: What environmental conditions and languages does the system support?
A: Operating within 15-35C and less than 80% relative humidity (non-condensing), the tester's environment settings can be adjusted via its chamber or external cabinet. The PC software supports English, Chinese, and customizable language options to suit user preferences.