Call Us
Send Inquiry
Moisture Vapor Transmission Rate Testing System for Food Packaging

Moisture Vapor Transmission Rate Testing System for Food Packaging

50000 USD ($)/Set

Product Details:

  • Resolution 0.001 g/m24h
  • Max Height 500 mm
  • Mounting Type Bench-top
  • Temperature 15C to 55C (adjustable)
  • Port Size 6 mm
  • Specimen Size 100 mm 100 mm
  • Number of Specimens 3 (independent test chambers)
  • Click to View more
X

Moisture Vapor Transmission Rate Testing System for Food Packaging Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set

Moisture Vapor Transmission Rate Testing System for Food Packaging Product Specifications

  • 20-90% RH (adjustable)
  • 3 (independent test chambers)
  • 100 mm 100 mm
  • AC 220V, 50Hz
  • Microprocessor based
  • Automated data logging, programmable, stable test environment, alarm system
  • 0.05-10,000 g/m24h
  • Bench-top
  • 0-80 mm
  • 20-100 mm
  • 500 mm
  • 0.001 g/m24h
  • 6 mm
  • Up to 3 parallel tests
  • Standard / Adjustable
  • 15C to 55C (adjustable)
  • 0.01 g/m24h
  • Automatic
  • 220 V AC
  • Food packaging film, flexible packaging material, polymer film, etc.
  • Digital LCD touch screen
  • <5 seconds
  • 0.05 to 10,000 g/m24h
  • Moisture Vapor Transmission Rate Testing System
  • Food packaging permeability test
  • 0.1-0.8 MPa
  • 50 Hz
  • RS232/USB
  • Approx. 55 kg

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR \ WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR \ WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Brand new rainbow bridge structural test cell and 360 air circulation constant temperature technology ensure better temperature stability.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • The test cell is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.

High Efficiency 6 Test Cells

  • Independent six sets of 50cm2 standard area test cells, which is three times the traditional oxygen transmission rate test instrument.
  • Six samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 6.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • Intelligent test cell hood which opens and closes automatically with sound and light alert.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Space Saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving laboratory space.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C406H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.02 200
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.02 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.02 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.02 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.15
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%, 100%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 6 test chambers
Specimen Size 4.6 x 4.611.7cm11.7cm)
Specimen Thickness 120 Mil3mm
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzeither one of two
Instrument Dimensions 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbs100kg

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument is 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Advanced Compliance and Versatile Testing

This MVTR Testing System meets global compliance with ISO 15106, ASTM F1249, and GB/T 26253 standards, making it suitable for international and local quality assurance. It supports multiple packaging materials, such as food packaging film and aluminum foil, through customizable testing parameters within a wide measuring and accuracy range. The system accommodates up to three parallel tests with independent chambers, optimizing testing efficiency for manufacturers and suppliers.


User-Friendly Operation and Accurate Results

The system features intuitive digital LCD touch-screen controls, automated and manual calibration, and programmable settings for temperature and humidity. Real-time data logging, rapid response time, and flexible result export (USB, printer) ensure highly reliable and traceable test records. The provision of sample holders and multilingual software (English/Chinese) simplifies the workflow, while an alarm system alerts users to over-limit or system faults for operational safety.

FAQs of Moisture Vapor Transmission Rate Testing System for Food Packaging:


Q: How does the Moisture Vapor Transmission Rate Testing System ensure compliance with international standards?

A: The MVTR Testing System is designed to comply with ISO 15106, ASTM F1249, and GB/T 26253 standards, ensuring results meet global food packaging industry requirements. The included calibration certificate verifies accuracy, and both automatic and manual calibration modes support reliable conformity.

Q: What is the procedure for testing different food packaging materials using this system?

A: To test various packaging materials, simply mount your sample (up to 100 mm 100 mm) on one of the three independent test chambers. Adjust parameters for temperature, humidity, and gas pressure as needed. The microprocessor-controlled system automatically conducts the test, logging and displaying data for review and export.

Q: Where should the equipment be installed for optimal operation?

A: The system should be set up in a clean, indoor, dust-free, and non-corrosive environment to maintain its performance and protect sensitive components. Bench-top installation is recommended, and dealer-provided support is available for setup upon request.

Q: What data management options are available with this testing system?

A: The equipment stores up to 50,000 test records internally. Results can be exported via USB or directly printed through the integrated printer. Data can be easily managed, tracked, and reviewed using the included multilingual (English, Chinese) software interface.

Q: How does the alarm system enhance safety during testing?

A: The built-in alarm system actively monitors for over-limit results and system faults. When any issue arises, alerts are displayed on the digital LCD screen, helping operators intervene promptly and prevent potential quality or safety issues.

Q: What materials are compatible for testing with this MVTR system?

A: This system is compatible with a range of food packaging materials, including plastic films, aluminum foil, and other flexible or polymer-based packaging. It supports a test width of 20100 mm and is ideal for permeability testing in food packaging development and quality control.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.