Product Description
Product Featuresnote1
OTR/WVTR tested in One Instrument
- OTR WVTR mode, OTR mode and WVTR mode are available for selection.
- OTR and WVTR tests can be automatically completed for each sample mounting.
- Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.
Coulometric Oxygen Sensor
- The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
- Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
- Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
- Over limit alarm and automatic protection.
Infrared Moisture Sensor
- The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
- Designed according to ASTM F1249.
- Longer service life, non-consumable.
- Over limit alarm and automatic protection.
Accurate Data
- Using 360 air circulation constant temperature technology, the temperature stability is better.
- Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
- In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
- Higher test repeatability of 0.01 cc / (m2day) can be achieved.
High Efficiency Three-cell
- Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
- Three samples can be tested at the same time under the same conditions, with independent tests data.
- In the same test cycle, the number of samples completed increases from 2 to 3.
- Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.
Intelligent Operation
- The 12 Inch Touch panel of windows system is used for more convenient operation.
- Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
- New drawer type test cell, one key automatic in-and-out with sound and light reminder.
Safe and Reliable
- Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
- Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
- Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.
Powerful Functions
- Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
- Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
- Wide temperature range, allowing the barrier test at different temperatures (customized).
- The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).
Testing Principle
The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.
Reference Standards
ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015
Test Applications
| Applications |
- Films
The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
|
- Sheets
The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.
|
Technical Specifications
Table 1: Test Parameters Note2
| Parameter/Model |
Model C403H |
| OTR Test Range |
cc/(m2day) (Standard area 50cm2) |
0.01 200 |
| cc/(m2day) (MASK area 5cm2) |
0.2 2000 (Optional) |
| cc/(m2day) (MASK area 1cm2) |
1 10000 (Optional) |
| OTR Resolution |
cc/(m2day) |
0.0001 |
| OTR Repeatability |
cc/(m2day) |
0.01 or 1%, whichever is greater |
| WVTR Test Range |
g/(m2day) (Standard area 50cm2) |
0.005 40 |
| g/(m2day) (MASK area 5cm2) |
0.2 400 (Optional) |
| g/(m2day) (MASK area 1cm2) |
1 2000 (Optional) |
| WVTR Resolution |
g/(m2day) |
0.0001 |
| WVTR Repeatability |
g/(m2day) |
0.005 or 2%, whichever is greater |
| Temperature range |
C |
15 - 50 5 60 (Customized) |
| Temperature fluctuation |
C |
0.05 |
| Humidity range |
%RH (Within standard temperature range) |
0%, 5 - 902% |
| Extended functions |
GP-01 Gas Purification Unit |
Optional |
| DataShieldTM Note3 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Test Chamber |
3 test chambers |
| Specimen Size |
4.4 x 4.4i1411.2cm11.2cm) |
| Specimen Thickness |
120 Mili143mmi14 |
| Standard Test Area |
50 cm2 |
| Carrier Gas |
99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope) |
| Carrier Gas Pressure |
40.6 PSI / 280 kPa |
| Port Size |
1/8 inch metal tubing |
| Power Supply |
120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14 |
| Instrument Dimensions |
23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm) |
| Net weight |
220Lbsi14100kgi14 |
Configurations
- Standard Configurations
- Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
- Optional Parts
- GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
- Remarks
- 1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.
Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.
Efficient Measurement of Barrier PropertiesOur equipment provides simultaneous assessment of oxygen and water vapor transmission rates for PVdC packaging films, enabling manufacturers to ensure their materials meet stringent protective standards. Featuring automatic calibration and easy-to-use microcomputer control, tests can be conducted efficiently with results displayed clearly on the integrated touch screen. The capacity to handle multiple specimens accelerates routine quality control or research tasks.
Advanced Sensor Technology and User-Friendly DesignEquipped with electrochemical sensors for oxygen and infrared detection for water vapor, the tester delivers high accuracy and fast response times (2 min). The automatic temperature and humidity control maintains stable testing conditions, and data can be stored or exported via USB or Ethernet interfaces. The stainless steel test chamber and shock-proof packaging ensure durability and safe transport.
Comprehensive Support and Flexible ApplicationWith features such as standard cutting templates and optional accessories like extra test chambers or a humidity generator, setup is straightforward. On-site installation and training from experienced service engineers ensures your staff can operate the device with confidence. The upgrade option for CO2 permeability makes this solution future-proof for evolving testing needs.
FAQ's of Oxygen and Water Vapor Barrier Properties of PVdC Packaging:
Q: How does the tester measure oxygen and water vapor barrier properties in PVdC packaging?
A: The tester uses advanced electrochemical sensors to detect oxygen and infrared sensors to monitor water vapor permeability through packaging films. Specimens are placed in the stainless steel test chamber, and the system automatically controls temperature and humidity, ensuring accurate each time.
Q: What is the process for preparing samples and running a test?
A: Samples are prepared using the included standard cutting template to ensure consistent size (100 mm 100 mm, up to 3 mm thick). After placement in the chamber, test parameters are set via the touch screen, and the microcomputer-controlled system automates the entire testing process. Test duration can range from 10 minutes to 48 hours, depending on required precision.
Q: When should I choose this tester for my barrier measurement needs?
A: This equipment is ideal if you need reliable, accurate, and repeatable testing of oxygen and water vapor permeability in PVdC or similar packaging materials-especially for quality assurance, R&D, and regulatory compliance. Multi-specimen capability and integrated data analysis make it suitable for both routine and specialized laboratory work.
Q: Where is this tester best suited for installation and use?
A: The tester is designed as a bench-top instrument, making it perfect for laboratory environments in manufacturing, research institutes, or quality control departments. Its stainless steel chamber and robust build ensure longevity and safety in both industrial and research settings.
Q: What are the main benefits of using this permeability tester?
A: Key benefits include high measurement accuracy (1%), automatic temperature and humidity control, rapid response (2 min), low noise levels, and user-friendly data management via USB, Ethernet, and RS-232. It is low maintenance and CE certified, with available on-site support and training.
Q: How does the automatic calibration and maintenance improve the testing workflow?
A: The automatic calibration feature eliminates manual calibration errors, reduces setup time, and ensures data reliability. Low maintenance requirements further streamline your workflow, minimizing instrument downtime and operational costs.
Q: What upgrade options and optional accessories are available for this equipment?
A: The tester supports module expansion for CO2 permeability measurements. Optional accessories include additional test chambers, a humidity generator, and shock-proof packaging for transportation, allowing enhanced flexibility and future scalability.