Call Us
Send Inquiry    Call Me Free
Non-Destructive Vial Leak Detecting Instrument Enhancing Product Quality & Compliance

Non-Destructive Vial Leak Detecting Instrument Enhancing Product Quality & Compliance

50000 USD ($)/Set

Product Details:

  • Operating Temperature 5C to 45C
  • Test Material Glass / Plastic Vials
  • Temperature 5C to 45C
  • Power Supply AC Supply
  • Display Digital LCD
  • Sensor High sensitivity pressure transducer
  • Number of Specimens Up to 10 vials per cycle
  • Click to View more
X

Non-Destructive Vial Leak Detecting Instrument Enhancing Product Quality & Compliance Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set
  • 50000 USD ($)/Set

Non-Destructive Vial Leak Detecting Instrument Enhancing Product Quality & Compliance Product Specifications

  • Automatic and Manual
  • Up to 500 ml vial capacity
  • 1% FS
  • Pharmaceutical vial leak detection
  • 18 kg
  • <2 seconds
  • 150 mm x 200 mm
  • Non-Destructive Leak Detecting Instrument
  • Anodized Aluminum
  • Standard 15 mm
  • 80% RH
  • 230 V AC, 50 Hz
  • Air / Inert Gas
  • Glass / Plastic Vials
  • 5C to 45C
  • 5C to 45C
  • AC Supply
  • Digital LCD
  • Up to 10 vials per cycle
  • High sensitivity pressure transducer
  • 2 ml to 500 ml
  • Adjustable from 0.1 to 6 bar

Product Description

Featuresnote1

Batch Testing

  • Equipped with fully-automatic gravity fed sample feeder, which is Labthinks latest scientific and technological achievement that can facilitate continuous testing of 20 to 120 samples.
  • A & B dual-channel design can test samples of two different specifications simultaneously.
  • The target vacuum degree can be set by the operator to meet testing requirements of different samples.
  • Dual methods of vacuum decay and pressure decay provide the flexibility to accommodate various types of package samples.

Precise Data

  • Advanced pressure detection technology, using world renowned components for data stability which is not affected by ambient environment.
  • Advanced microflow automatic flow control technology that can accurately simulate different sizes of leakage holes without manual adjustment.
  • Both the differential pressure transducer and flow meter are traceable to NIST.
  • The system can achieve a higher test repeatability of 1um.

Intelligent Control

  • 15.6" embedded touch tablet computer with Windows OS.
  • New longitudinal interface layout, and easy to use graphic user interface.
  • Automatic alarm, automatic capture, automatic collection of unqualified samples.
  • The pressure curve is displayed in real time, and the test results are counted automatically.
  • Leakage rates are calculated automatically.
  • The system is equipped with various sensors as intelligent reminders for safer operation and control.
  • Universal printer can be connected for test results output.
  • The system features embedded with USB and network ports to facilitate the external access and data transmission of the system, which can be upgraded remotely

Security Compliance

  • Verified by compensation and calibration methods.
  • The leak tester meets GMP requirements for data traceability and meets the needs of the pharmaceutical industry.
  • User operation permission is managed at multiple levels, and the permission content can be configured on demand.
  • Electronic signature is designed according to the standard requirements of 21 CFR Part11.

Test Principle

The sample is placed in the sample feeder and automatically delivered into the test cell. The leak rate and other results can be calculated and obtained by analyzing pressure changes measured by the sensor.

Reference Standards

ASTM F2338, YY-T 0681.18, and USP<1207>

Applications

Basic Applications Vials Various vial sealing test.
Extended Applications Ampoule Various ampoule bottle sealing tests.
Cartridge Bottles Various cartridge bottle sealing tests.
Injection bottles Various injection bottles sealing test.

Technical Parameters

Table 1: Test Parameters Note2

Parameter\Model C690H
Testing Range um(Reference aperture size USP1207) 38great leakage
Detection Lower Limit um 3
Resolution um 0.1
Repeatability um 1
Pressure Range kPa -1000100
Extended Functions 21 CFR Part11 Optional
GMP computer system requirements Optional

Table 2: Technical Specifications

Testing Cell 1 set for A group and 1 set for B group
Sample Feeder 1 set for A group and 1 set for B group
Sample Size 45 mm80mmNote3
Sample Quantity 20120 pieces
Gas Specifications Compressed Air (Gas source is provided by the user)
Gas Source Pressure 40.6 PSI / 500 kPa
Port Size 6 mm Polyurethane tube
Dimensions 33.4 H x 19.6 W x 28.7 D (85cm 50cm 73cm)
Power 120VAC10% 60Hz / 220VAC10% 50Hzselect one from the two
Net weight 209Lbs (95kg)

Product Configuration

Standard Configuration Mainframe, embedded tablet computer, software, flow meter, European vacuum pump, 6 mm polyurethane tube
Customization Test cell and sample feeder of group A, test cell and sample feeder of group B, negative standard reference sample and positive standard reference sample designed according to sample specifications
Optional Parts GMP computer system requirements, 21 CFR Part11, air compressor, IQ/OQ/PQ documents

Note 1: The described product characteristics are subject to the specific annotation of the "Technical Parameters" table.
Note 2: The parameters in the table are measured in the Labthink laboratory by professional operators according to the requirements and conditions of the relevant laboratory environmental standards.
Note 3: Group C test cell can be customized for samples beyond the "Sample Size", but the lower detection limit and test range will change according to the sample size, and the actual delivery shall prevail.



Ensuring Non-Destructive Testing and Reliable Compliance

With vacuum decay and pressure differential technology, this instrument delivers non-destructive leak detection for various vial types without contaminating or damaging samples. Fully compliant with GMP and 21 CFR Part 11, it supports modern data integrity practices. Its robust alarm system and data connectivity further enhance quality control and regulatory fulfilment.


Optimized for Cleanrooms and Flexible Operations

The instrument is suitable for Grade A/B cleanroom environments, ensuring product sterility is maintained. Its benchtop or floor-standing design, adjustable sample holders, and compatibility with both glass and plastic vials provide operational flexibility, while automatic/manual calibration modes streamline set-up.

FAQs of Non-Destructive Vial Leak Detecting Instrument Enhancing Product Quality & Compliance:


Q: How does the vial leak detecting instrument work to identify leaks?

A: The instrument uses vacuum decay and pressure differential technologies to non-destructively detect leaks in vials. By closely monitoring pressure changes within a sealed test chamber, it identifies any deviations indicative of micro-leaks in both liquid and lyophilized vial products.

Q: What regulatory standards and compliance requirements does this device meet?

A: This leak detector meets GMP, 21 CFR Part 11, and other global regulatory standards. It supports secure data logging, traceability, and includes full validation protocols (IQ/OQ/PQ), ensuring readiness for compliance audits.

Q: When should calibration or validation of the device be performed?

A: Calibration can be carried out either automatically or manually as part of standard operating procedurescommonly during initial setup, routine maintenance, or as required by quality management policies. Validation support via IQ/OQ/PQ protocols is provided and should be executed during installation and whenever major changes are made.

Q: Where can this instrument be installed, and is it suitable for pharmaceutical cleanrooms?

A: Designed for flexibility, the instrument is installation-ready for benchtop or floor-standing configurations and is fully suitable for Grade A/B cleanrooms, aligning with stringent pharmaceutical manufacturing standards.

Q: What is the typical process for testing vials using this device?

A: Operators place up to 10 vials in adjustable sample holders, select the test parameters via the touchscreen HMI, and initiate the test. The instrument cycles within 1030 seconds, providing digital LCD results while securely logging data for review or export.

Q: What are the key benefits of using this non-destructive leak detection technology?

A: Users benefit from fast, accurate, and non-destructive testing, reduced risk of contamination, streamlined compliance with major regulations, efficient data management, and minimal maintenanceultimately enhancing product quality and operational efficiency.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Leak and Integrity Tester' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.