Product Details:

  • Interface Type USB Port
  • Port Size Standard 8mm Air Port
  • Accuracy 1% FS
  • Power Supply AC 220V, 50Hz
  • Number of Specimens Up to 3 simultaenously
  • Temperature 10~40C
  • Response Time 1s
  • Click to View more
X

Key Packaging Test for Medical Packaging Sealing Strength Price And Quantity

  • 1 Set
  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set

Key Packaging Test for Medical Packaging Sealing Strength Product Specifications

  • AC 220V, 50Hz
  • 1% FS
  • Standard 8mm Air Port
  • USB Port
  • Up to 3 simultaenously
  • 10~40C
  • Digital/Touchscreen Control
  • 500 N
  • 220V
  • Bench-top
  • 1s
  • Medical Packaging Sealing Strength Test
  • 50 Hz
  • 400 mm
  • LCD Display
  • Approx. 40 kg
  • 0~500 N
  • 50~500 mm/min (Adjustable)
  • 300 mm
  • 0.4~0.7 MPa
  • Seal Strength, Peeling, and Tensile Test for Medical Packaging
  • Sealing Strength Tester
  • Automatic
  • 500 mm
  • Touchscreen operation, automatic data statistics, printing report
  • Maximum 300 mm width
  • 20~80% RH
  • 0.01 N
  • 0~500 N

Product Description

Product FeaturesNote1

Ten Test Modes to Meet Various Testing Demands

  • Ten independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, puncture test of rubber closure and puncture retention force test, etc. at users choice
  • The instrument supports bidirectional testing modes, which can be used for puncture test of rubber closure and breaking force test of ampoule and test speed can be adjusted freely
  • Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users

Excellent Testing Mechanism & Improved Test Accuracy

  • Force measuring system is supplied by top global supplier, ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
  • Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
  • Global renowned brand pneumatic control system supports pneumatic specimen clamping, avoids the specimen slipping and guarantees the accuracy of test data

High-end, Secure and Easy-to-Use Embedded Computer-controlled System

  • The instrument is integrated with software requiring no external computer
  • The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
  • Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
  • The instrument is equipped with USB ports and Internet ports for convenient data transmission.
  • Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.

Test StandardNote1

ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130

Applications

C610M is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:

Basic Applications
  • Shearing Test
  • Test of Tensile Strength and Elongation Rate
  • Test of Tensile Strength at Break
  • Tear Resistance Test
  • Heatseal Strength Test
  • 90 Degree Peel Test
  • 180 Degree Peel Test
  • Tensile Strength Test at Defined Elongation
Extended Applications
(Additional Accessories Required)
  • Puncture Test of Hypodermic Needles in Artificial Skin
  • Puncture Test of Films
  • Puncture Test of Infusion Bags
  • Puncture/Pullout Test of Flexible Rubber Closures
  • Opening Resistance Test of Combined Covers
  • Tear Test of ZD - Type Caps
  • Opening Force Test of Oral Liquid Caps
  • Puncture/Pullout Test of Oral Liquid Caps
  • 90 Degree Pullout Test of Infusion Bag Caps
  • Pullout Test of Infusion Bag Caps
  • 23 Degree Pullout Test of Bottle Caps
  • Puncture/Pullout Test of Bottle Caps or Rubber Closures
  • 90 Degree Peel Test of Adhesive Tapes
  • Tear Resistance Test of Adhesive Binding Books
  • 90 Degree Peel Test of Water-soluble Plasters
  • Tear Resistance Test of Adhesives
  • Adhesive Strength Test (soft)
  • Adhesive Strength Test (hard)
  • Peel Test of Flexible Tube Caps
  • Removal Force of Pipes and Pipe Joints
  • Pullout Test of Cosmetic Brush Hair
  • Pullout Test of Tooth Brush Hair
  • Tensile Strength of Ropes at Break
  • Opening Force Test of Jelly Cups and Yogurt Cups
  • Peel Test of Cup Films
  • Pullout Test of Rubber Stoppers
  • 45 Degree Peel Test of Bottle Membranes
  • Tensile Strength of Sealing Bags
  • Peel Test of Magnetic Cores
  • 90 Degree Peel Test of Magnetic Cards
  • Tear Resistance of Heat Sealing Films
  • Separating Force of Protection Films
  • Peel Test of Release Paper
  • Tear Test Using Trouser Method
  • Unwrapping Force of Adhesive Tapes
  • Compressive Resistance of Plastic Bottles
  • 20 Degree Peel Test
  • 135 Degree Peel Test of Plugs
  • Peeling Grips of Floating Rollers
  • Eccentric Grips
  • Wide Sample Grips
  • Japanese Sample Grips
  • British Sample Grips
  • Tensile Strength of Contact Lenses at Break
  • Compression Resistance of Jelly Cups
  • Compression Resistance of Package
  • Compression Resistance of Sponge
 

Technical Specifications

Specifications C610M Auto Tensile Tester
Load Cell Capacity 500 N (standard)
50 N, 100 N, 250 N, 1000 N (optional) 5N (Customization available)
Accuracy 0.5% of indicated value (2%FS 100%FS)
0.01%FS (0% 2%FS)
Resolution 0.001 N
Test Speed 0500 mm/min
Speed Accuracy 0.5% of indicated value
Number of Specimens 1
Specimen Width 30 mm (Standard Grip)
50 mm (Optional Grip)
Clamping Way Pneumatic Specimen Clamp
Gas Supply Air (outside of supply scope)
Gas Supply Pressure 0.5 MPa 0.7 MPai1472.5psii101.5psii14
Stroke 950 mm (customization available for 1200mm)
Instrument Dimension 450 mm (L) x 450 mm (W) x 1410 mm (H)
Power Supply 220VAC10% 50Hz / 120VAC10% 60Hz
Net Weight 95 kg

Configurations

Standard Configurations
Instrument (with embedded software), LCD Monitor, Keyboard, Mouse, Pneumatic Sample Girps
Optional Parts
Standard Pressure Roller, Test Plate, Sample Cutter, Air Compressor
Note
1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.

Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



High-Sensitivity Load Cell for Precise Measurements

Utilizing a high-sensitivity load cell, this tester provides accurate readings for peel, tensile, and sealing strength tests. The wide measurement range (0~500 N) and 1% FS accuracy meet rigorous quality standards in medical packaging and ensure reliable results for product validation.


User-Friendly Digital Control and Touchscreen Operation

Equipped with a touchscreen LCD display, the tester offers intuitive control, easy parameter adjustment, and swift access to automated data statistics. The digital interface streamlines workflow, facilitating quick calibration and real-time monitoring for efficient testing processes.


Comprehensive Safety and Compliance Features

The tester integrates emergency stop and overload protection for operator safety. Compliance with ISO 11607 and ASTM F88 guarantees that testing meets global medical packaging guidelines, while internal memory storage and built-in reporting functions ensure secure data management.

FAQ's of Key Packaging Test for Medical Packaging Sealing Strength:


Q: How does the Sealing Strength Tester measure the sealing strength of medical packaging?

A: The tester uses a high-sensitivity load cell to measure sealing strength by applying controlled force to the seals of medical packaging. It records data on peel, tensile, and sealing strength, providing highly accurate results suitable for compliance with ISO 11607 and ASTM F88.

Q: What is the process for calibrating the tester?

A: The device supports both automatic and manual calibration modes. To calibrate, users can follow the touchscreen prompts for automated calibration or refer to the user manual for manual calibration procedures, ensuring the instrument maintains precision for every test run.

Q: When is it beneficial to use this tester in medical packaging production?

A: It is beneficial to use this tester during product development, quality control, and routine compliance checks. Testing sealing strength early and regularly helps manufacturers maintain product integrity, meet regulatory standards, and minimize packaging failures.

Q: Where can the results be stored and accessed after testing?

A: Test results are stored in the tester's internal memory. They can be printed immediately using the built-in thermal printer or exported via USB and RS232 ports to a computer for further analysis or record-keeping.

Q: How many specimens can be tested at once, and what are the specimen size limitations?

A: The equipment facilitates simultaneous testing of up to three specimens, each with a maximum width of 300 mm, optimizing throughput without compromising accuracy.

Q: What safety and protection features are included in the tester?

A: For user safety, the tester includes emergency stop and overload protection mechanisms. These features help prevent equipment damage and protect operators during high-force testing procedures.

Q: What are the main benefits of using this sealing strength tester for medical packaging?

A: Benefits include highly accurate, fast, and consistent results, compliance with key industry standards, user-friendly operation via touchscreen, automated data reporting and storage, and robust safety features, making it ideal for manufacturers and quality control labs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Packaging Testing Instrument' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.