Product Description
Featuresnote1
Batch Testing
- Equipped with fully-automatic gravity fed sample feeder, which is Labthinks latest scientific and technological achievement that can facilitate continuous testing of 20 to 120 samples.
- A & B dual-channel design can test samples of two different specifications simultaneously.
- The target vacuum degree can be set by the operator to meet testing requirements of different samples.
- Dual methods of vacuum decay and pressure decay provide the flexibility to accommodate various types of package samples.
Precise Data
- Advanced pressure detection technology, using world renowned components for data stability which is not affected by ambient environment.
- Advanced microflow automatic flow control technology that can accurately simulate different sizes of leakage holes without manual adjustment.
- Both the differential pressure transducer and flow meter are traceable to NIST.
- The system can achieve a higher test repeatability of 1um.
Intelligent Control
- 15.6" embedded touch tablet computer with Windows OS.
- New longitudinal interface layout, and easy to use graphic user interface.
- Automatic alarm, automatic capture, automatic collection of unqualified samples.
- The pressure curve is displayed in real time, and the test results are counted automatically.
- Leakage rates are calculated automatically.
- The system is equipped with various sensors as intelligent reminders for safer operation and control.
- Universal printer can be connected for test results output.
- The system features embedded with USB and network ports to facilitate the external access and data transmission of the system, which can be upgraded remotely
Security Compliance
- Verified by compensation and calibration methods.
- The leak tester meets GMP requirements for data traceability and meets the needs of the pharmaceutical industry.
- User operation permission is managed at multiple levels, and the permission content can be configured on demand.
- Electronic signature is designed according to the standard requirements of 21 CFR Part11.
Test Principle
The sample is placed in the sample feeder and automatically delivered into the test cell. The leak rate and other results can be calculated and obtained by analyzing pressure changes measured by the sensor.
Reference Standards
ASTM F2338, YY-T 0681.18, and USP<1207>
Applications
| Basic Applications |
Vials |
Various vial sealing test. |
| Extended Applications |
Ampoule |
Various ampoule bottle sealing tests. |
| Cartridge Bottles |
Various cartridge bottle sealing tests. |
| Injection bottles |
Various injection bottles sealing test. |
Technical Parameters
Table 1: Test Parameters Note2
| Parameter\Model |
C690H |
| Testing Range |
um(Reference aperture size USP1207) |
38great leakage |
| Detection Lower Limit |
um |
3 |
| Resolution |
um |
0.1 |
| Repeatability |
um |
1 |
| Pressure Range |
kPa |
-1000100 |
| Extended Functions |
21 CFR Part11 |
Optional |
| GMP computer system requirements |
Optional |
Table 2: Technical Specifications
| Testing Cell |
1 set for A group and 1 set for B group |
| Sample Feeder |
1 set for A group and 1 set for B group |
| Sample Size |
45 mm80mmNote3 |
| Sample Quantity |
20120 pieces |
| Gas Specifications |
Compressed Air (Gas source is provided by the user) |
| Gas Source Pressure |
40.6 PSI / 500 kPa |
| Port Size |
6 mm Polyurethane tube |
| Dimensions |
33.4 H x 19.6 W x 28.7 D (85cm 50cm 73cm) |
| Power |
120VAC10% 60Hz / 220VAC10% 50Hzselect one from the two |
| Net weight |
209Lbs (95kg) |
Product Configuration
| Standard Configuration |
Mainframe, embedded tablet computer, software, flow meter, European vacuum pump, 6 mm polyurethane tube |
| Customization |
Test cell and sample feeder of group A, test cell and sample feeder of group B, negative standard reference sample and positive standard reference sample designed according to sample specifications |
| Optional Parts |
GMP computer system requirements, 21 CFR Part11, air compressor, IQ/OQ/PQ documents |
Note 1: The described product characteristics are subject to the specific annotation of the "Technical Parameters" table.
Note 2: The parameters in the table are measured in the Labthink laboratory by professional operators according to the requirements and conditions of the relevant laboratory environmental standards.
Note 3: Group C test cell can be customized for samples beyond the "Sample Size", but the lower detection limit and test range will change according to the sample size, and the actual delivery shall prevail.
Advanced Leak Detection for Superior Packaging IntegrityLeveraging pressure decay technology, this NDT Package Leak Tester identifies minute leaks in various packaging materials without causing any damage. It is suitable for both laboratories and production sites, making it a valuable tool for manufacturers and quality assurance teams alike. The non-destructive process ensures products remain intact and contamination-free.
Efficient and User-Friendly OperationFeaturing digital LCD displays and automatic controls, the tester provides real-time data acquisition with intuitive software compatible with Windows. Reports are easily exported in PDF or CSV formats. Maintenance requirements are minimal, and tool-free access allows for hassle-free servicing, ensuring consistent performance with little downtime.
Versatility and ComplianceWith the capacity to test up to five specimens at once, this tester accommodates a wide variety of pouch shapes and sizes. Its compliance with international standards like ASTM F2338 and EN 1779 guarantees reliable, industry-approved resultsmaking it indispensable for producers, suppliers, and retailers seeking top-tier package quality assurance.
FAQs of Preventing Contamination and Spoilage with NDT Package Leak Testing:
Q: How does the NDT Package Leak Tester prevent contamination and spoilage in packaging?
A: By using a non-destructive pressure decay method, the tester accurately detects leaks that could allow contaminants to enter, ensuring product safety and shelf-life. Immediate feedback allows timely corrective actions, thereby maintaining package integrity throughout storage and distribution.
Q: What types of packaging materials can be tested with this equipment?
A: The NDT Package Leak Tester is compatible with plastic, foil, composite, and glass packages. This versatility makes it ideal for a wide range of food, pharmaceutical, and industrial packaging applications.
Q: When and how often should the equipment be calibrated to ensure accurate results?
A: Calibration is recommended once per month to maintain the testers high level of accuracy (0.5% F.S.), supporting reliable and repeatable leak detection results.
Q: Where can the NDT Package Leak Tester be used?
A: This equipment is designed for laboratory and production site environments, suitable for settings ranging from research facilities to commercial manufacturing lines in need of stringent quality control.
Q: What is the process for leak testing with this device?
A: Testing involves placing one to five specimens (up to 300 mm in size) in the unit. With digital controls, operators can select random, batch, or continuous sampling. The device initiates the pressure decay test, displaying real-time graphical data and producing reports without requiring special sample preparation.
Q: How easy is it to maintain and operate the tester?
A: Minimal, tool-free maintenance is required, simplifying daily use and servicing. The digital interface and automatic controls streamline operation, making it accessible for operators with varying technical expertise.
Q: What are the key benefits of using this NDT Package Leak Tester?
A: Major advantages include rapid and accurate leak detection, compliance with ASTM and EN standards, real-time data acquisition, flexibility in packaging types, easy data export, and the ability to enhance quality control processeshelping businesses prevent costly contamination and spoilage incidents.