Product Description
Product FeaturesNote1
Multiple Test Modes & Intelligent Statistics of Qualified Specimens
- Negative pressure method
- Multiple test modes including standard, multi-grade vacuum and methylthionine chloride mode
- Automatic test with traditional methylthionine chloride
- Vacuum degree, test time and infiltration time can be adjusted and test parameters can be saved automatically so that the tests with same test parameters can be started quickly
- Automatic constant pressure compensation ensures that the tests can be performed under preset vacuum conditions
- Real-time display of test curves, easy to observe the test results
- Automatic statistics of qualified specimens
- Main components and parts are supplied by well-known global manufacturers, with guaranteed performance
Brand New Patented Intelligent Touch Operating System
- Industrial grade touch screen, one-button operation, simplified operating interface, remote upgrade and maintenance
- Chinese and English operating interface
- Measurement unit conversion
- Automatic data storage and power failure memory to prevent data loss
- Storage up to 1200 test records (standard mode)
- Multiple-level user management and login with password
- Micro-printer and USB ports for data transmission (optional)
- The instrument conforms to the requirements of GMP (optional)
- Labthinks unique DataShiledTM System for data management and connecting with information system (optional)
Test Principle
Firstly submerge the specimen in the water in the vacuum chamber, and then evacuate the vacuum chamber to form differential pressure between the inside and outside of specimen. The seal property can be obtained by observing the steady progression of bubbles from the specimen or observing how the specimen expands and restores to its original shape after vacuum release.
Test StandardNote1
ASTM D3078, GB/T 15171
Applications
| Basic Applications |
- Glass Bottles, Pipes, Cans and Boxes
|
- Plastic Bottles, Pipes, Cans and Boxes
|
- Metal Bottles, Pipes, Cans and Boxes
|
- Paper Plastic Composite Bags and Boxes
|
| Extended Applications |
|
|
|
|
|
|
Technical Specifications
| Specifications |
C660B |
| Vacuum Degree |
0 -90 KPa/ 0 -13 psi |
| Accuracy |
0.25% FS |
| Resolution |
0.1 KPa / 0.01 psi |
Vacuum Chamber Effective Sizes |
I270 mm x 210 mm (H) (standard) |
| I360 mm x 585 mm (H) (optional) |
| I460 mm x 330 mm (H) (optional) |
| Note: customization is available for other sizes |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 Mpa (73psi 101psi) |
| Instrument Dimension |
334 mm (L) x 230 mm (W) x 170 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
Instrument: 6.5 kg Standard Vacuum Chamber: 9kg |
Configurations
- Standard Configurations
- Instrument, Standard Vacuum Chamber (I270 mm x 210 mm), I6 PU Tubing (1m)
- Optional Parts
- Micro Printer, Professional Software, Customized Vacuum Chamber, Air Compressor, GMP System, DataShieldTM Note3
- Note
- 1. The gas supply port of the instrument isI6 mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Advanced Testing Precision and VersatilityEquipped with force and pressure sensors, this system offers highly accurate measurements (0.5% FS) and operates across a wide range (1N-500N). Compatible with various IV bag materials, it adapts to different sizes and delivers consistent, reproducible results. Its test speed and width capacity accommodate multiple testing scenarios, meeting the diverse needs of manufacturers and exporters.
Comprehensive Data Management and AnalysisThe large test result storage (1000+ records) combined with flexible data output formats (PDF, CSV) streamlines workflow, while built-in software provides detailed reporting and analysis. Convenient USB and RS232 interfaces enable seamless integration with laboratory systems, ensuring easy documentation and regulatory compliance.
Optimized Safety and User ExperienceVisual and audible alarm systems, emergency stop features, and tool-free low maintenance enhance operational safety and efficiency. Touch screen and PC controls allow intuitive operation in laboratory or clean room environments, making it user-friendly for routine and specialized IV bag package testing.
FAQ's of Comprehensive Solution for IV Bag Packaging Testing and Quality Control:
Q: How does this automated IV bag packaging testing system ensure reliable quality control?
A: The system uses high-precision force and pressure sensors to conduct rigorous leak detection, seal strength, and volume retention tests. It provides automated, repeatable testing procedures, ensuring consistent quality control that meets ISO 8536 standards.
Q: What types of IV bag materials can be tested with this equipment?
A: This machine is compatible with common IV bag materials, including PVC, Polyolefin, and EVA, enabling it to be used across a broad range of product lines by manufacturers, suppliers, and exporters.
Q: When should calibration be performed and how is it achieved?
A: Calibration is essential for accurate test results and can be performed automatically by the machine or manually if needed. It's recommended to calibrate before initial use, after significant maintenance, or periodically as indicated by your quality protocols.
Q: Where can this testing system be installed and operated?
A: Designed for laboratory and clean room environments, the bench-top system's compact size and robust construction (48 kg) make it suitable for installation in most quality control or R&D facilities.
Q: What is the process for conducting a standard test using this machine?
A: Start by mounting up to five specimens, configure settings via the touchscreen or PC software, and run the desired test. The machine will automatically conduct the procedure, record precise data, and alert users via visual/audio alarms upon completion or issue detection.
Q: How does the equipment enhance safety during operation?
A: Safety features include an emergency stop button and both visual and audible alarm systems to promptly signal users of any irregularities, ensuring personnel protection during automated testing cycles.
Q: What are the main benefits of using this automated testing system for IV bag packaging?
A: This system offers fast, accurate, and repeatable testing with comprehensive data storage and reporting, minimizing manual errors and increasing efficiency. It ensures compliance with international standards while providing flexible, user-friendly operation and low maintenance demands.