Call Us
Send Inquiry    Call Me Free
Hot Tack Testers

Hot Tack Testers

50000 USD ($)/Set

Product Details:

  • Humidity 30% - 80% RH
  • Measuring Range 0.01 N - 250 N
  • Frequency 50 Hz
  • Specimen Size 100 mm x 15 mm
  • Equipment Type Hot Tack Tester
  • Operating Voltage 220V AC
  • Temperature Ambient to 250C
  • Click to View more
X

Hot Tack Testers Price And Quantity

  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set
  • Manual / auto / programmable
  • Included
  • Adjustable, 0-50 N
  • 0.2 - 0.7 MPa
  • Automatic & manual calibration options
  • Temperature 10C to 40C, humidity 85%
  • Over-temperature and pressure protection
  • USB exportable, internal storage
  • Air cooled clamps
  • Compatible with Windows OS
  • High-grade stainless steel
  • Stores up to 500 test results

Hot Tack Testers Product Specifications

  • Single/dual specimen option
  • Laboratory/quality control
  • USB / RS232
  • 50 mm max
  • 450 mm
  • Approx. 45 kg
  • Bench-top
  • Digital color touchscreen
  • Automatic
  • <100 ms
  • 6 mm pneumatic input
  • 10 - 500 mm/min
  • Auto data logging, data export, programmable test sequences
  • 220V AC, 50Hz
  • 0 - 250 N
  • 0.5% F.S.
  • 0.01 N
  • 0.5 - 0.8 MPa
  • Measurement of hot tack strength in packaging films
  • Programmable touch-screen PLC
  • 50 mm
  • 0 - 250 N
  • Ambient to 250C
  • Hot Tack Tester
  • 220V AC
  • 50 Hz
  • 100 mm x 15 mm
  • 0.01 N - 250 N
  • 30% - 80% RH
  • Manual / auto / programmable
  • Included
  • Adjustable, 0-50 N
  • 0.2 - 0.7 MPa
  • Automatic & manual calibration options
  • Temperature 10C to 40C, humidity 85%
  • Over-temperature and pressure protection
  • USB exportable, internal storage
  • Air cooled clamps
  • Compatible with Windows OS
  • High-grade stainless steel
  • Stores up to 500 test results

Product Description

Product FeaturesNote1

Constant Pressure & Automated Sample Feeding

  • Automatic pressure control technology manages the pressure fluctuation within 0.005MPa
  • The test pressure can be set through the program without manual adjustment
  • Automatic sample feeding technology to ensure the accuracy of test time
  • Upper and lower sealing jaws with metal surfaces can obtain more authentic thermal tack performance
  • Digital P.I.D temperature control technology enables the tester to reach the set temperature quickly, effectively avoids temperature fluctuations

Safety Design & Automatic Sample Clamping

  • The overall protective cover is designed to prevent hand pinching, scalding and collision, making sure the operation is safer
  • Preload fixtures are convenient for sample clamping.
  • Pneumatic sample clamping saves time and effort, with consistent clamping force and better sealing efficiency.
  • Observation window for clear monitoring of the test process

Intelligent Control & Reliable Performance

  • The 7 Inch industrial level Touch panel control for easier operation.
  • Sensor static design, reducing force fluctuation
  • AC servo system, more stable high-speed operation
  • Global sourced core components ensure low failure rate and long service life
  • The self-detection function warns of over heat and over limit.
  • Support display of multiple units in MPa and PSI.
  • Functions of automatic data saving, power failure automatic memory to prevent data loss.
  • Multi-level user authority management, login with password.
  • Micro-printer and universal USB data interface for convenient data output and transmission(optional).
  • DataShieldTM Data Management System enables centralized data management and convenient information system connection (optional)

Test StandardNote1

GB/T 34445, ASTM F1921

Applications

Basic Applications
  • Plastic films, sheets and composite films e.g. PE, PP, PET and composite films used in packages for instant noodle, milk powder, washing powder, food and drugs
Extended Applications
  • Hot seal test of flexible plastic film and composite film.

Technical SpecificationsNote2

Table 1: Test Parameters Note2

Parameter/Model C632M
Load Cell Capacity N 50
Force Accuracy FS 0.5
Force Resolution N 0.001
Pressure range MPa 0.05i0.7
Pressure resolution MPa 0.001
Temperature range Room temperature 250
Temperature fluctuation 0.2
Test Speed mm/min 1500a200012000
Heat Seal Dwell Time s 0.1999.9
Delay time s 0.01999.99
Extended functions Software Optional
DataShieldTM Note3 Optional
Microprinter Optional

Table 2: Technical Specifications

Sealing Jaw 1 Set (Double heating)
Jaw surface Metal
Jaw size 100 mm x 10mm
Fixture width 35 mm
Sample width 15 mm or 25 mm or 25.4 mm
Fixtures distance 350 mm
Air supply Dry air (out of supply scope)
Air source pressure 101.5PSI / 0.7 MPa
Port size I6mm PU tubing
Dimensions 32 H x 17 W x 19 D (81cm 43cm 48cm)
Power 120VAC10% 60Hz / 220VAC10% 50Hz (one of two)
Net weight 133Lbsi1460kgi14

Configurations

Standard Configurations
Mainframe, pneumatic fixtures, sampler, pedal switch, 6 mm tubing
Optional Parts
Software, air compressor and DataShieldTM Data ShieldNote3
Remarks
The inlet of the air compressor uses 6 mm tubingi14101.5PSI / 0.7 MPai14, the air source is out of supply scope.

Note 1:All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3:DataShieldTM Data Management System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.



Cutting-Edge Hot Tack Measurement

This Hot Tack Tester is essential for quality assurance in film packaging. With automated programmable modes and a high-resolution force range from 0.01 N up to 250 N, it provides fast, precise evaluations. The air-cooled stainless steel clamping system and accurate digital feedback make it ideal for laboratories concerned with packaging integrity.


Seamless Data Handling and Comprehensive Safety

The machine accommodates up to 500 test results in its internal memory, with effortless data export via USB or RS232 interfaces for detailed reporting. Automatic and manual calibration options paired with over-temperature and pressure protection assure operational safety and measurement validity during repetitive testing.


Versatile Operation and User-Friendly Control

Featuring a touch-screen PLC for parameter input and real-time control, this tester supports various specimen formats and both single and dual testing modes. Its sample preparation template, wide sealing pressure and test speed ranges, and compatibility with Windows OS software enhance laboratory workflow and productivity.

FAQ's of Hot Tack Testers:


Q: How do I calibrate the Hot Tack Tester for accurate measurements?

A: The Hot Tack Tester supports both automatic and manual calibration through its programmable touch-screen PLC interface. Follow the on-screen prompts for auto-calibration, or use standard weights and the included procedure for manual adjustment to maintain high accuracy (0.5% F.S.).

Q: What data storage and exporting features does this tester offer?

A: The instrument has internal storage for up to 500 test results. Data can be exported easily via USB or RS232 interfaces, allowing seamless integration with Windows OS-based analysis and reporting systems.

Q: When should I use the over-temperature and over-pressure protection features?

A: These safety features automatically engage to prevent equipment damage or inaccurate test results if preset thresholds are exceeded during sealing or testing, ensuring secure operation at all times.

Q: Where can the Hot Tack Tester be effectively installed or mounted?

A: Designed as a bench-top unit, the tester can be placed in any controlled lab or quality control environment meeting the specified conditions: operating temperature between 10C and 40C and humidity up to 85% (non-condensing).

Q: What is the process for preparing film samples for testing?

A: Use the included sample preparation template to cut the specimens to the required size (100 mm x 15 mm). The device supports both single and dual specimen options for flexible testing configurations.

Q: How does the programmable control mode improve testing efficiency?

A: The integrated PLC touch-screen allows users to create, save, and execute programmable test sequences, reducing manual intervention and increasing consistency and throughput during repetitive hot tack evaluations.

Q: What are the primary benefits of using this Hot Tack Tester in packaging film evaluation?

A: It delivers highly accurate, repeatable hot tack measurements, streamlines data management, and ensures safety-making it invaluable for laboratories and packaging film manufacturers focused on quality assurance and product development.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Packaging Testing Instrument' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.