Product Description
Product FeaturesNote1
Constant Pressure & Automated Sample Feeding
- Automatic pressure control technology manages the pressure fluctuation within 0.005MPa
- The test pressure can be set through the program without manual adjustment
- Automatic sample feeding technology to ensure the accuracy of test time
- Upper and lower sealing jaws with metal surfaces can obtain more authentic thermal tack performance
- Digital P.I.D temperature control technology enables the tester to reach the set temperature quickly, effectively avoids temperature fluctuations
Safety Design & Automatic Sample Clamping
- The overall protective cover is designed to prevent hand pinching, scalding and collision, making sure the operation is safer
- Preload fixtures are convenient for sample clamping.
- Pneumatic sample clamping saves time and effort, with consistent clamping force and better sealing efficiency.
- Observation window for clear monitoring of the test process
Intelligent Control & Reliable Performance
- The 7 Inch industrial level Touch panel control for easier operation.
- Sensor static design, reducing force fluctuation
- AC servo system, more stable high-speed operation
- Global sourced core components ensure low failure rate and long service life
- The self-detection function warns of over heat and over limit.
- Support display of multiple units in MPa and PSI.
- Functions of automatic data saving, power failure automatic memory to prevent data loss.
- Multi-level user authority management, login with password.
- Micro-printer and universal USB data interface for convenient data output and transmission(optional).
- DataShieldTM Data Management System enables centralized data management and convenient information system connection (optional)
Test StandardNote1
GB/T 34445, ASTM F1921
Applications
| Basic Applications |
- Plastic films, sheets and composite films e.g. PE, PP, PET and composite films used in packages for instant noodle, milk powder, washing powder, food and drugs
|
| Extended Applications |
- Hot seal test of flexible plastic film and composite film.
|
Technical SpecificationsNote2
Table 1: Test Parameters Note2
| Parameter/Model |
C632M |
| Load Cell Capacity |
N |
50 |
| Force Accuracy |
FS |
0.5 |
| Force Resolution |
N |
0.001 |
| Pressure range |
MPa |
0.05i0.7 |
| Pressure resolution |
MPa |
0.001 |
| Temperature range |
|
Room temperature 250 |
| Temperature fluctuation |
|
0.2 |
| Test Speed |
mm/min |
1500a200012000 |
| Heat Seal Dwell Time |
s |
0.1999.9 |
| Delay time |
s |
0.01999.99 |
| Extended functions |
Software |
Optional |
| DataShieldTM Note3 |
Optional |
| Microprinter |
Optional |
Table 2: Technical Specifications
| Sealing Jaw |
1 Set (Double heating) |
| Jaw surface |
Metal |
| Jaw size |
100 mm x 10mm |
| Fixture width |
35 mm |
| Sample width |
15 mm or 25 mm or 25.4 mm |
| Fixtures distance |
350 mm |
| Air supply |
Dry air (out of supply scope) |
| Air source pressure |
101.5PSI / 0.7 MPa |
| Port size |
I6mm PU tubing |
| Dimensions |
32 H x 17 W x 19 D (81cm 43cm 48cm) |
| Power |
120VAC10% 60Hz / 220VAC10% 50Hz (one of two) |
| Net weight |
133Lbsi1460kgi14 |
Configurations
- Standard Configurations
- Mainframe, pneumatic fixtures, sampler, pedal switch, 6 mm tubing
- Optional Parts
- Software, air compressor and DataShieldTM Data ShieldNote3
- Remarks
- The inlet of the air compressor uses 6 mm tubingi14101.5PSI / 0.7 MPai14, the air source is out of supply scope.
Note 1:All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3:DataShieldTM Data Management System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.
Cutting-Edge Hot Tack MeasurementThis Hot Tack Tester is essential for quality assurance in film packaging. With automated programmable modes and a high-resolution force range from 0.01 N up to 250 N, it provides fast, precise evaluations. The air-cooled stainless steel clamping system and accurate digital feedback make it ideal for laboratories concerned with packaging integrity.
Seamless Data Handling and Comprehensive SafetyThe machine accommodates up to 500 test results in its internal memory, with effortless data export via USB or RS232 interfaces for detailed reporting. Automatic and manual calibration options paired with over-temperature and pressure protection assure operational safety and measurement validity during repetitive testing.
Versatile Operation and User-Friendly ControlFeaturing a touch-screen PLC for parameter input and real-time control, this tester supports various specimen formats and both single and dual testing modes. Its sample preparation template, wide sealing pressure and test speed ranges, and compatibility with Windows OS software enhance laboratory workflow and productivity.
FAQ's of Hot Tack Testers:
Q: How do I calibrate the Hot Tack Tester for accurate measurements?
A: The Hot Tack Tester supports both automatic and manual calibration through its programmable touch-screen PLC interface. Follow the on-screen prompts for auto-calibration, or use standard weights and the included procedure for manual adjustment to maintain high accuracy (0.5% F.S.).
Q: What data storage and exporting features does this tester offer?
A: The instrument has internal storage for up to 500 test results. Data can be exported easily via USB or RS232 interfaces, allowing seamless integration with Windows OS-based analysis and reporting systems.
Q: When should I use the over-temperature and over-pressure protection features?
A: These safety features automatically engage to prevent equipment damage or inaccurate test results if preset thresholds are exceeded during sealing or testing, ensuring secure operation at all times.
Q: Where can the Hot Tack Tester be effectively installed or mounted?
A: Designed as a bench-top unit, the tester can be placed in any controlled lab or quality control environment meeting the specified conditions: operating temperature between 10C and 40C and humidity up to 85% (non-condensing).
Q: What is the process for preparing film samples for testing?
A: Use the included sample preparation template to cut the specimens to the required size (100 mm x 15 mm). The device supports both single and dual specimen options for flexible testing configurations.
Q: How does the programmable control mode improve testing efficiency?
A: The integrated PLC touch-screen allows users to create, save, and execute programmable test sequences, reducing manual intervention and increasing consistency and throughput during repetitive hot tack evaluations.
Q: What are the primary benefits of using this Hot Tack Tester in packaging film evaluation?
A: It delivers highly accurate, repeatable hot tack measurements, streamlines data management, and ensures safety-making it invaluable for laboratories and packaging film manufacturers focused on quality assurance and product development.