Product Description
Product FeaturesNote1
Professional Test Modes to Meet Various Testing Demands
- Multiple independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, and compression test, etc. at users choice
- The instrument supports bidirectional testing modes and test speed can be adjusted freely
- Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users
Excellent Testing Mechanism & Improved Test Accuracy
- Force measuring system is supplied by top global supplier, which ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
- Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
- Global renowned brand pneumatic control system supports pneumatic specimen clamping, which avoids the specimen slipping and guarantees the accuracy of test data
High-end, Secure and Easy-to-Use Embedded Computer-controlled System
- Large size touch screen tablet for better viewing and easy operation
- Brand new software and system provide smooth and simplified operating experience
- The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
- Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
- The instrument is equipped with USB ports and Internet ports for convenient data transmission.
- Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.
Test StandardNote1
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
C610H is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:
| Basic Applications |
|
|
- Test of Tensile Strength and Elongation Rate
|
- Test of Tensile Strength at Break
|
|
|
|
|
|
|
|
|
- Tensile Strength Test at Defined Elongation
|
Extended Applications (Additional Accessories Required) |
- Puncture Test of Hypodermic Needles in Artificial Skin
|
|
- Puncture Test of Infusion Bags
|
- Puncture/Pullout Test of Flexible Rubber Closures
|
- Opening Resistance Test of Combined Covers
|
- Tear Test of ZD - Type Caps
|
- Opening Force Test of Oral Liquid Caps
|
- Puncture/Pullout Test of Oral Liquid Caps
|
- 90 Degree Pullout Test of Infusion Bag Caps
|
- Pullout Test of Infusion Bag Caps
|
- 23 Degree Pullout Test of Bottle Caps
|
- Puncture/Pullout Test of Bottle Caps or Rubber Closures
|
- 90 Degree Peel Test of Adhesive Tapes
|
- Tear Resistance Test of Adhesive Binding Books
|
- 90 Degree Peel Test of Water-soluble Plasters
|
- Tear Resistance Test of Adhesives
|
- Adhesive Strength Test (soft)
|
- Adhesive Strength Test (hard)
|
- Peel Test of Flexible Tube Caps
|
- Removal Force of Pipes and Pipe Joints
|
- Pullout Test of Cosmetic Brush Hair
|
- Pullout Test of Tooth Brush Hair
|
- Tensile Strength of Ropes at Break
|
- Opening Force Test of Jelly Cups and Yogurt Cups
|
|
|
- Pullout Test of Rubber Stoppers
|
- 45 Degree Peel Test of Bottle Membranes
|
- Tensile Strength of Sealing Bags
|
- Peel Test of Magnetic Cores
|
- 90 Degree Peel Test of Magnetic Cards
|
- Tear Resistance of Heat Sealing Films
|
- Separating Force of Protection Films
|
- Peel Test of Release Paper
|
- Tear Test Using Trouser Method
|
- Unwrapping Force of Adhesive Tapes
|
- Compressive Resistance of Plastic Bottles
|
|
|
- 135 Degree Peel Test of Plugs
|
- Peeling Grips of Floating Rollers
|
|
|
|
|
|
|
- Tensile Strength of Contact Lenses at Break
|
- Compression Resistance of Jelly Cups
|
- Compression Resistance of Package
|
- Compression Resistance of Sponge
|
|
Technical SpecificationsNote2
| Specifications |
C610H Auto Tensile Tester |
| Load Cell Capacity |
500 N (standard) 50 N, 100 N, 250 N, 1000 N (optional) |
| Accuracy |
0.5% of indicated value (2%FS100%FS) 0.01%FS (0% 2%FS) |
| Resolution |
0.001 N |
| Test Speed |
0.05 500 mm/min |
| Speed Accuracy |
0.5% of indicated value (1%100% of maximum speed) |
| Number of Specimens |
1 |
| Specimen Width |
30 mm (Standard Grip) |
| 50 mm (Optional Grip) |
| Clamping Way |
Pneumatic Specimen Clamp |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 Mpa (72.5psii101.5psi) |
| Stroke |
1000 mm |
| Instrument Dimension |
500 mm (L) 520 mm (W) 1900 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
110 kg |
Configurations
- Standard Configurations
- Instrument, Professional Software, Tablet, Pneumatic Sample Grips
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Customized Grips, Laser Printer, Air Compressor, Computer System required by GMP, DataShieldTM Note3
- Note
- 1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Precise and Versatile TestingThis instrument delivers accurate pull-tab and tear strength measurements across milk, juice, and other beverage cartons, accommodating various sizes with adjustable clamps and a 0-500N range. Designed for both producers and quality assurance labs, its microcomputer control ensures consistent results, while the user-friendly manual mode offers flexibility for diverse sample types.
Comprehensive Safety and ComplianceSafety is prioritized with features like an emergency stop and overload alarm, protecting both users and specimens. The device meets ISO 12048 and GB/T 1040 standards, ensuring reliable, globally-recognized testing. With robust construction and semi-automatic operation, it supports regular quality control operations with minimal risk.
Streamlined Data ManagementIntegrated digital LED display and dedicated PC software facilitate real-time monitoring and instant data export in CSV/EXCEL formats. Experience smooth workflow, from testing up to three specimens at once, to rapidly sharing and analyzing results through USB/RS232 connections. Automated reporting enhances efficiency and keeps records organized.
FAQ's of Milk Carton Quality Control and Pull-Tab Testing Instrument:
Q: How does the instrument perform milk carton pull-tab strength testing?
A: The device uses adjustable clamps to secure carton tabs and applies a controlled force (0-500N) at selectable speeds (10-300 mm/min). The pull strength or tear force is measured, allowing you to assess product quality and compliance with industry standards.
Q: What materials and carton sizes are compatible with this instrument?
A: The tester accommodates milk, juice, and beverage cartons within a size range of 60x60 mm to 100x200 mm, ensuring compatibility with most common liquid packaging. Its design and customizable port sizes enhance versatility across multiple packaging types.
Q: When is calibration required and how is it performed?
A: Calibration should be conducted prior to initial use and regularly as part of routine quality assurance. The standard weight calibration method ensures accuracy, following the instrument's user manual and recommended schedules.
Q: Where can the exported data be accessed and in what formats?
A: Test reports can be exported via USB or RS232 interfaces in CSV or EXCEL formats. This allows for straightforward integration into laboratory information management systems or external QC databases.
Q: What safety features are integrated into the equipment?
A: The instrument is equipped with an emergency stop button, overload alarm, and auto-stop function to enhance operator safety, minimize specimen damage, and prevent accidental overloads during tests.
Q: What are the main benefits of using this testing instrument for quality control?
A: Benefits include accurate and repeatable results (1%), efficient testing of up to three samples at once, automated data collection, compatibility with international testing standards, and robust real-time reporting via dedicated software.