Product Description
High Precision
- Patented test chamber and test dishes with advanced fluid dynamics and thermodynamic designs.
- Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
- Precise and scientific regulation and calculation of testing conditions.
High Efficiency
- 12 test stations
- Supports test modes of desiccant method and water method
Labor Saving
- Automatic humidity and flow rate controlling.
- Desiccator requires no replacement of inner core.
- High-efficiency water vapor generator.
Simplified Operation
- 12 touch-screen pad powered by WindowsTM 10 operating system
- Fast automatic testing process
- Optional DataShieldTM software and accessories for automatic data management
Product Features
New Generation Test Chamber and Test Dishes
Patented test chamber and test dishes with advanced hydrodynamic and thermodynamic designs ensure the uniform flow rate over the specimen surface, stable temperature and humidity, creating a uniform and stable testing environment. As a result, the test duration is shortened and the test results will be more accurate.
Excellent Testing Abilities of High and Low Barrier Materials
The testing conditions will be regulated precisely in real time, which ensures the high testing accuracy and repeatability of high and low barrier materials.
Automatic Controlling of Temperature, Humidity and Air Velocity
Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
Air velocity is monitored and regulated in real time.
High-efficiency and mist-free automatic humidity regulator meets the requirements for long-term continuous tests.
It is unnecessary to replace the inner core of the desiccator, which can continuously work for 20,000 hours.
Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system facilitates centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.
User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.
Test Principle
The test specimen is mounted in the test dish which contains water or desiccant inside. The test dish is placed in the test chamber with stable temperature, humidity and air flow. The water vapor permeates through the specimen and into the dry side. By measuring the weight changes of the test dish periodically, water vapor transmission rate and other parameters can be obtained.
Test Standards
ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, GB/T 1037, GB/T 16928, YBB 00092003-2015
Applications
| Basic Applications |
- Films
Plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminum coated films, aluminum foil composite films, glass fiber aluminum foil paper composite films and many other film materials
|
- Sheeting
PP, PVC and PVDC sheeting, metal foils, rubber pads and other sheeting materials
|
- Paper and Paper Board
Aluminum coated paper for cigarette, paper aluminum plastic composite film and other paper and paperboards
|
- Textiles and Nonwovens
Textiles and nonwoven fabrics
|
| Extended Applications |
- Construction Materials
Geotextiles, felt, roofing and building materials, vapor barrier membranes, etc.
|
- Aseptic Wound Protection Films and Medical Plasters
Aseptic wound protecting films, medical plasters and protective clothing materials
|
Technical Specifications
Table 1: Test Parameters Note1
| Parameter |
Model C360H |
| Testing Efficiency |
0.01g/(m2day) 0.5g/(m2day) |
>24 hours |
| 0.0006g/(100in2day) 0.0323g/(100in2day) |
| 0.5 g/(m2day)5 g/(m2day) |
12 24 hours |
| 0.0323g/(100in2day) 0.3225g/(100in2day) |
| > 5 g/(m2day) |
12 hours |
| > 0.3225 g/(100in2day) |
| Max. Test Range |
Water Method |
10000/ni141-12i14g/(m2day) |
| 645/ni141-12i14g/(100in2day) |
| Desiccant Method |
1200g/(m2day) per piece |
| 77g/(100in2day) per piece |
| Test Station |
|
12 |
| Test Temperature |
C |
20 55 0.2 |
| Test Humidity |
RH |
10% 90% 1% |
| Additional Functions |
DataShieldTM Note2 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Specimen Size |
I74mm |
| Specimen Thickness |
3mm |
| Test Method |
Desiccant Method / Water Method |
| Standard Test Area |
33cm2 |
| Carrier Gas |
Compressed Air |
| Drying of Carrier Gas |
Long Service-life Desiccator (unnecessary to replace inner core) |
| Humidifying of Carrier Gas |
High-efficiency mist-free humidity generator |
| Carrier Gas Pressure |
0.6 MPa |
| Port Size |
I6mm PU Tubing |
Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.
Reliable Moisture Barrier TestingEngineered to deliver reproducible results, this instrument measures water vapor transmission rates from 0.01 to 10,000 g/m2/24h across polyethylene geomembranes. The combination of automatic testing, precise calibration, and high-pressure sealing ensures dependable data for quality assurance and product development.
Intuitive Real-Time Data ManagementWith digital LCD display and PC software integration, users benefit from real-time monitoring and comprehensive reporting. Data storage functions simplify record keeping and analysis, while the RS232/USB interfaces streamline connectivity for seamless export operations.
Advanced Safety and User ControlThe tester incorporates multiple safety features including emergency stop and overload protection. With controlled humidity (40%-90% RH) and temperature (room to 70C), as well as automatic over-temperature alerts, operators can safely conduct tests in bench-top settings under optimized conditions.
FAQ's of Polyethylene Geomembrane Water Vapor and Moisture Barrier Properties Testing:
Q: How does the Polyethylene Geomembrane Moisture Barrier Tester ensure accurate measurements?
A: Accuracy is assured through high-precision humidity sensors, auto and manual calibration options, and a high-seal pressure, leak-proof test chamber constructed from stainless steel. The tester's digital controls and microcomputer interface further minimize user error.
Q: What standards does the equipment conform to for moisture vapor testing?
A: This instrument adheres to ASTM E96, ISO 2528, and GB/T 1037 testing standards, meeting global requirements for water vapor transmission rate evaluation in geomembrane and polyethylene film materials.
Q: When should this moisture barrier tester be used?
A: The tester is ideal for quality control, research and development, and compliance verification processes in industries involved with geomembrane or polyethylene films. Use it whenever moisture barrier properties require precise assessment.
Q: Where can the Polyethylene Geomembrane Moisture Barrier Tester be operated?
A: It's designed for bench-top setup in laboratories, manufacturing facilities, and supplier environments-any controlled space with 0-50C temperature and less than 80% relative humidity, using a standard 220V AC power supply.
Q: What is the process for conducting a moisture permeability test on geomembrane specimens?
A: Specimens (100 mm) are mounted in the test chamber, which is set to controlled humidity and temperature. After setting test speed and stroke, the microcomputer automates data collection, which is displayed instantly and stored for later analysis.
Q: How many specimens can be tested simultaneously on this equipment?
A: The device accommodates one to three specimens simultaneously, allowing efficient comparative analysis and faster throughput during moisture vapor transmission testing.
Q: What benefits does this moisture barrier tester offer manufacturers and exporters?
A: Manufacturers and exporters gain rapid, accurate measurements that meet international standards, alongside automated reporting, easy calibration, and robust safety features, enhancing product quality and market competitiveness.