Call Us
Send Inquiry
C106H Gas Permeability Test System

C106H Gas Permeability Test System

50000 USD ($)/Set

Product Details:

  • Accuracy 2% (full scale)
  • Resolution 0.01 cm/(m24h0.1MPa)
  • Application For testing gas permeability of plastic films, sheeting, and other flat materials
  • Hardness n/a (not applicable)
  • Frequency 50Hz
  • Test Range 0.05-5000 cm/(m24h0.1MPa)
  • Interface Type USB, RS232
  • Click to View more
X

C106H Gas Permeability Test System Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set
  • 1 Cubic Centimeter

C106H Gas Permeability Test System Product Specifications

  • 7-inch TFT LCD Touchscreen
  • Ambient 15-50C (0.2C)
  • 3 independent test cells
  • Adjustable, up to 120 tests/hour
  • AC 220V 10%, 50Hz
  • Automated temperature & humidity control, data storage, multi-unit parallel test capability
  • 30% - 90% RH (programmable)
  • Approx. 60 kg
  • Low, Medium, High (selectable)
  • 600 mm
  • 0.01-0.1 MPa (adjustable)
  • Automatic
  • Benchtop
  • 220V AC
  • 1/4 inch NPT
  • 1-3 simultaneously
  • Standard: 100 mm
  • n/a (not applicable)
  • For testing gas permeability of plastic films, sheeting, and other flat materials
  • 0.01 cm/(m24h0.1MPa)
  • 2% (full scale)
  • Touchscreen control, automatic
  • 0.05-5000 cm/(m24h0.1MPa)
  • 50Hz
  • USB, RS232
  • 10 sec
  • 0-300 mm (adjustable)
  • Gas Permeability Test System
  • 97 mm diameter (standard)
  • Laboratory, Quality Control

Product Description

Product FeaturesNote1

Accurate Data

  • Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
  • Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01-0.09cm3/ m3*24h*0.1MPa test range.
  • Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
  • Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
  • The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
  • Labthink's unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
  • The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.

High Efficiency

  • Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
  • Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
  • Medium and low barrier materials, test time <4 hours (including vacuumize time).
  • High barrier materials, test time <4 hours (including vacuumize time).
  • Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.

Intelligent control

  • 12'' touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
  • Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
  • Intelligent test chamber hood automatically opens and closes with sound and light alert

Safe and reliable

  • System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
  • Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
  • Performance reliability--the instrument adopts components of global renowned brands, to ensure stable and reliable performance.

Space saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.

Powerful functions

  • Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
  • The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
  • Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
  • Ultra-wide test range to meet the barrier test of various materials (customize).
  • Tests of hazardous gases such as H2, CH4 are applicable (Customize).

Test Principle

The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.

Standard

ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1 ,YBB 00082003

Applications

Applications
  • Films
    Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
  • Sheets
    Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials

Technical Specifications

Table 1: Test Parameters Note2

Parameters/Model C106H
Test range cm3/m2*24h*0.1MPa 0.01-50,000
Resolution cm3/m2*24h*0.1MPa 0.001
Test temperature
15-50i145-60i14Optionali14
Temperature resolution
0.01
Temperature fluctuation
0.15
Test humidity %RHi14Within standard test temperature rangei14 0%i145-902%i14Customizei14
Vacuum Resolution Pa 0.01
Vacuum Accuracy Pa 0.2%i141%-100% of Full Scalei14
Vacuum Degree of Test Chamber Pa  10
Additional Functions DataShieldTM note3 Optional
GMP Computer System requirement Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Cell 6 Cells
Specimen Size 4.6'' x 4.6''i1411.7cmx11.7cmi14
Specimen Thickness 120 Mili143mmi14
Standard test area 38.48cm2
Test Gas O2, N2, CO2 etc.i14Outside of supply scopei14
Test Pressure 10 kPa210 kPai14Can be set betweeni14
Pressure Fluctuation 0.2 kPa
Gas Pressure 79.7 PSI / 550 kPa
Port Size 6 mm PU tubing
Instrument Dimension 23.6'' H x 19.2'' W x 25.9'' D (60cmx 49cmx 66cm)
Power Supply 120VAC
10% 60Hz/220VAC10% 50Hzi14one of twoi14
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuratio

Standard Configuration Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, 6 mm PU tubing
Optional Parts Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3
Note The gas compressor port of the instrument is 6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply.

Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.



High-Precision Measuring Technology

Equipped with advanced pressure sensors, the C106H Gas Permeability Test System ensures consistent and accurate detection of gas transmission rates. Its 2% accuracy and 0.01 cm3/(m224h0.1MPa) resolution enable highly reliable measurements for demanding film and sheet applications.


Advanced Control and User-Friendly Operation

The system features a 7-inch TFT LCD touchscreen interface, allowing intuitive navigation of settings, test modes, and real-time monitoring. Operators benefit from automatic and manual calibration functions, flexible data export options, and programmable environmental controls for precise testing conditions.


Comprehensive Compliance and Versatility

The C106H meets international standards (ASTM, ISO, GB/T), with multiple gas compatibility and the option to test up to three specimens simultaneously, making it ideal for laboratory, quality control, and research environments.

FAQ's of C106H Gas Permeability Test System:


Q: How do I operate the C106H Gas Permeability Test System for different specimens?

A: Simply place specimens (97 mm diameter standard) into the stainless steel test chambers, select required carrier gas and measuring range, then use the touchscreen interface to initiate either manometric or volumetric tests. The system can accommodate 1-3 specimens simultaneously.

Q: What gases can the C106H system use for permeability testing?

A: The system supports Oxygen, Nitrogen, and Carbon Dioxide as carrier gases, selectable based on application needs or material requirements.

Q: When should I perform calibration, and what calibration options are available?

A: Calibration is recommended before starting a new series of measurements or after significant usage. The C106H provides both automatic and manual calibration modes for flexibility and precise sensor adjustment.

Q: Where should the device be installed for optimal performance?

A: Install the C106H in an indoor, dust-free, vibration-free environment to ensure stable measurements and minimize interference in test results.

Q: What is the process for exporting test data from the system?

A: After completing tests, data can be exported via USB in CSV or PDF format, allowing for easy recordkeeping, analysis, and reporting. The system stores up to 100,000 records for comprehensive data management.

Q: How does the test system benefit laboratory and quality control work?

A: Its automation, multi-specimen capability, flexible gas selection, and fast test speed (up to 120 tests/hour) streamline workflows, boost efficiency, and ensure internationally compliant results for material evaluation and R&D.

Q: What materials are suitable for testing with the C106H system?

A: The C106H is designed for gas permeability testing of plastic films, sheeting, and other flat barrier materials, supporting multiple industry applications, including packaging, manufacturing, and research.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.