Product Details:

  • Frequency 50 Hz
  • Resolution 0.001 g/m24h
  • Test Range 0.005 - 200 g/m24h
  • Display Type LCD Touch Panel
  • Application Cosmetics Packaging Barrier Performance
  • Accuracy 0.01 g/m24h
  • Max Height 350 mm
  • Click to View more
X

Choosing the Right Packaging Barrier Testing for Cosmetics Packaging Maximizing Shelf Life Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set

Choosing the Right Packaging Barrier Testing for Cosmetics Packaging Maximizing Shelf Life Product Specifications

  • 0.01 g/m24h
  • Touch Screen / Software
  • 32 kg
  • 0.005 - 200 g/m24h
  • 0.001 g/m24h
  • 50 Hz
  • Cosmetics Packaging Barrier Performance
  • LCD Touch Panel
  • Customizable
  • Fully Automatic
  • 0.01 - 500 g/m24h
  • 5C - 50C
  • 350 mm
  • 220V/50Hz
  • Benchtop
  • 10% - 90% RH
  • Barrier Testing Machine
  • Barrier testing for maximizing shelf life
  • Up to 3
  • 100 mm 100 mm
  • RS232/USB
  • 250 mm
  • 10 - 500 mm/min
  • High Throughput
  • 300 mm
  • 0.1 - 0.5 MPa
  • 2 sec
  • 220V
  • Auto Data Logging, Multi-channel Testing, Real-time Monitoring

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR \ WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR \ WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Brand new rainbow bridge structural test cell and 360 air circulation constant temperature technology ensure better temperature stability.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • The test cell is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.

High Efficiency 6 Test Cells

  • Independent six sets of 50cm2 standard area test cells, which is three times the traditional oxygen transmission rate test instrument.
  • Six samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 6.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • Intelligent test cell hood which opens and closes automatically with sound and light alert.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Space Saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving laboratory space.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C406H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.02 200
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.02 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.02 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.02 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.15
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%, 100%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 6 test chambers
Specimen Size 4.6 x 4.611.7cm11.7cm)
Specimen Thickness 120 Mil3mm
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzeither one of two
Instrument Dimensions 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbs100kg

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument is 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Maximizing Cosmetics Shelf Life with Advanced Barrier Testing

Accurate barrier testing helps cosmetics manufacturers extend product shelf life by verifying packaging integrity against moisture, oxygen, and other external factors. Using internationally recognized standards such as ASTM, ISO, JIS, and GB, this machine ensures compliance and confidence in packaging performance. Fully automatic operation, data logging, and real-time monitoring streamline processes, while user-focused design enhances safety and efficiency in laboratory and R&D environments.


Unmatched Precision and Versatility for Laboratories

With high-resolution measurement, touch screen control, and compatibility for up to three specimens at once, the Barrier Testing Machine delivers precise, reproducible results for a broad range of packaging types. Environmental compensation and customizable test parameters ensure dependable performance even in varying laboratory conditions, supporting consistent product quality and accelerated development cycles.

FAQs of Choosing the Right Packaging Barrier Testing for Cosmetics Packaging Maximizing Shelf Life:


Q: How does barrier testing contribute to maximizing the shelf life of cosmetic products?

A: Barrier testing evaluates the effectiveness of packaging materials in blocking moisture, oxygen, and other elements that could degrade cosmetic formulations. By selecting packaging with verified barrier performance, manufacturers can reduce spoilage and extend the safe, effective shelf life of their products.

Q: What testing standards are supported by this barrier testing machine?

A: The machine is designed to support ASTM, ISO, JIS, and GB standards, ensuring regulatory compliance and reliable, standardized results suitable for global markets.

Q: When should I perform barrier performance testing for my cosmetics packaging?

A: Barrier testing should be conducted during the packaging design phase, product development, and as part of ongoing quality control to ensure that packaging continues to meet required performance standards throughout production.

Q: Where can this barrier testing machine be installed and used?

A: This benchtop machine is suitable for installation in laboratories, quality control departments, and R&D centers within cosmetics manufacturing facilities. Professional installation services are available upon request for optimal setup.

Q: What is the process for preparing cosmetic packaging samples for testing?

A: Sample preparation is simplified with included cutting dies and sealing fixtures, allowing users to create specimens (up to three at once, 100 mm 100 mm each) that are ready for evaluation under controlled humidity and temperature settings.

Q: How does the automatic calibration benefit users?

A: Automatic calibration ensures that the machine remains accurate and reliable over time, reducing manual intervention and maintaining traceable, consistent test results crucial for regulatory and quality assurance purposes.

Q: What are the key advantages of using this barrier testing machine for cosmetics packaging?

A: High throughput capacity, real-time data monitoring, auto data logging, customizable settings, and built-in safety features collectively enable faster, more reliable product testing, speeding up decision-making and supporting effective shelf life maximization.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.