Product Details:

  • Resolution 0.001 g/m2/24h
  • Response Time Instantaneous
  • Accuracy 0.01 g/m2/24h
  • Interface Type USB/RS232
  • Mounting Type Table Top
  • Power Supply AC 220V 50Hz
  • Temperature 15-50C
  • Click to View more
X

Testing Moisture Vapor Transmission Rate (MVTR) of Desiccant Packaging for Improving Product Shelf Life Price And Quantity

  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Set

Testing Moisture Vapor Transmission Rate (MVTR) of Desiccant Packaging for Improving Product Shelf Life Product Specifications

  • 0.01 g/m2/24h
  • 0.001 g/m2/24h
  • Instantaneous
  • 50 Hz
  • 0.001-10 g/m2/24h
  • 400 mm
  • 30 mm
  • Lab Testing for Shelf Life Improvement
  • High
  • Automatic
  • AC 220V 50Hz
  • Table Top
  • USB/RS232
  • 15-50C
  • 100 mm x 100 mm
  • 0-100% RH
  • 50-300 mm
  • MVTR Testing Machine
  • Microcomputer Controlled
  • 220 V
  • Standard
  • 10-50 mm/min
  • 0.6 MPa
  • 70 kg
  • Wide
  • Robust Build
  • 1-3
  • Desiccant Packaging Moisture Barrier Testing
  • LCD Digital Display
  • User-friendly Interface, Data Logging

Product Description

Product Features

New Generation Test Chamber and Test Dishes
Patented test chamber and test dishes with advanced hydrodynamic and thermodynamic designs ensure the uniform flow rate over the specimen surface, stable temperature and humidity, creating a uniform and stable testing environment. As a result, the test duration is shortened and the test results will be more accurate.

Excellent Testing Abilities of High and Low Barrier Materials
The testing conditions will be regulated precisely in real time, which ensures the high testing accuracy and repeatability of high and low barrier materials.

Automatic Controlling of Temperature, Humidity and Air Velocity
Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
Air velocity is monitored and regulated in real time.
High-efficiency and mist-free automatic humidity regulator meets the requirements for long-term continuous tests.
It is unnecessary to replace the inner core of the desiccator, which can continuously work for 20,000 hours.

Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.

The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system facilitates centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.

User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.

Test Principle

The test specimen is mounted in the test dish which contains water or desiccant inside. The test dish is placed in the test chamber with stable temperature, humidity and air flow. The water vapor permeates through the specimen and into the dry side. By measuring the weight changes of the test dish periodically, water vapor transmission rate and other parameters can be obtained.

Test Standards

ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, GB/T 1037, GB/T 16928, YBB 00092003-2015

Applications

Basic Applications
  • Films
    Plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminum coated films, aluminum foil composite films, glass fiber aluminum foil paper composite films and many other film materials
  • Sheeting
    PP, PVC and PVDC sheeting, metal foils, rubber pads and other sheeting materials
  • Paper and Paper Board
    Aluminum coated paper for cigarette, paper aluminum plastic composite film and other paper and paperboards
  • Textiles and Nonwovens
    Textiles and nonwoven fabrics
Extended Applications
  • Construction Materials
    Geotextiles, felt, roofing and building materials, vapor barrier membranes, etc.
  • Aseptic Wound Protection Films and Medical Plasters
    Aseptic wound protecting films, medical plasters and protective clothing materials

Technical Specifications

Table 1: Test Parameters Note1

Parameter Model C360H
Testing Efficiency 0.01g/(m2day) 0.5g/(m2day) >24 hours
0.0006g/(100in2day) 0.0323g/(100in2day)
0.5 g/(m2day)5 g/(m2day) 12 24 hours
0.0323g/(100in2day) 0.3225g/(100in2day)
> 5 g/(m2day) 12 hours
> 0.3225 g/(100in2day)
Max. Test Range Water Method 10000/ni141-12i14g/(m2day)
645/ni141-12i14g/(100in2day)
Desiccant Method 1200g/(m2day) per piece
77g/(100in2day) per piece
Test Station   12
Test Temperature C 20 55 0.2
Test Humidity RH 10% 90% 1%
Additional Functions DataShieldTM Note2 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Specimen Size I74mm
Specimen Thickness 3mm
Test Method Desiccant Method / Water Method
Standard Test Area 33cm2
Carrier Gas Compressed Air
Drying of Carrier Gas Long Service-life Desiccator (unnecessary to replace inner core)
Humidifying of Carrier Gas High-efficiency mist-free humidity generator
Carrier Gas Pressure 0.6 MPa
Port Size I6mm PU Tubing

Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.



High-Precision MVTR Testing for Shelf Life Optimization

Accurate evaluation of moisture vapor transmission is vital for desiccant packaging used in pharmaceuticals, food, and electronics industries. Our MVTR Testing Machine leverages state-of-the-art sensors and stainless steel construction to ensure precise measurements. Auto-calibration supports ongoing accuracy, and large data storage with export capability streamlines reporting and analysis. Compliance with global standards means manufacturers can trust results across markets.


User-Friendly Operation & Automated Workflows

Designed for ease of use, the system features a microcomputer-controlled interface, digital LCD display, and proprietary Windows-based software for testing automation and data management. With included calibration kits, sample holders, and easy maintenance access, lab technicians can achieve consistent, repeatable results with minimal setup. Integrated alarm functions protect specimens and ensure safety. The machine's quiet operation suits various laboratory settings.

FAQ's of Testing Moisture Vapor Transmission Rate (MVTR) of Desiccant Packaging for Improving Product Shelf Life:


Q: How does the MVTR Testing Machine help improve the shelf life of desiccant packaging?

A: By accurately measuring the rate at which moisture vapor passes through desiccant packaging, the MVTR Testing Machine enables manufacturers to select optimal materials and designs, thus enhancing moisture protection and extending product shelf life.

Q: What process does the machine use to test moisture vapor transmission rate?

A: The MVTR Testing Machine uses both gravimetric and infrared sensor methods to assess moisture vapor transmission rate. High-precision humidity and temperature sensors monitor the environment, and test parameters are controlled via microcomputer for consistent and reliable measurements.

Q: When should I use this equipment for testing my packaging materials?

A: It is best to test packaging materials both during development and before large-scale production. Routine quality checks with this equipment ensure that batches consistently meet moisture barrier standards, helping prevent costly product degradation.

Q: Where is the MVTR Testing Machine typically used?

A: This testing machine is ideal for laboratory environments within the packaging, pharmaceutical, food, and electronics industries. Its table-top design and robust build make it suitable for R&D and quality control labs focused on improving shelf life.

Q: What are the key benefits of using this MVTR Testing Machine?

A: Key benefits include high accuracy (0.01 g/m2/24h), wide measurement range, rapid test speeds (10-50 mm/min), automated calibration, data export capabilities, and compliance with ASTM and ISO standards, all contributing to reliable and efficient packaging quality assurance.

Q: How is the collected test data managed and exported from the device?

A: Test data is securely stored in the machine's large internal memory and can be easily exported via USB or RS232 interface. The proprietary Windows-based software enables streamlined data logging, analysis, and report generation as part of the workflow.

Q: What makes this machine easy to maintain and service?

A: The machine is designed for easy access, facilitating routine cleaning and maintenance. It includes a calibration kit and features auto-calibration, while the robust build ensures long-term durability and reliable daily operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Water Vapor Transmission Rate Tester' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.