Product Description
Product FeaturesNote1
Professional Test Modes to Meet Various Testing Demands
- Multiple independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, and compression test, etc. at users choice
- The instrument supports bidirectional testing modes and test speed can be adjusted freely
- Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users
Excellent Testing Mechanism & Improved Test Accuracy
- Force measuring system is supplied by top global supplier, which ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
- Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
- Global renowned brand pneumatic control system supports pneumatic specimen clamping, which avoids the specimen slipping and guarantees the accuracy of test data
High-end, Secure and Easy-to-Use Embedded Computer-controlled System
- Large size touch screen tablet for better viewing and easy operation
- Brand new software and system provide smooth and simplified operating experience
- The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
- Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
- The instrument is equipped with USB ports and Internet ports for convenient data transmission.
- Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.
Test StandardNote1
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
C610H is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:
| Basic Applications |
|
|
- Test of Tensile Strength and Elongation Rate
|
- Test of Tensile Strength at Break
|
|
|
|
|
|
|
|
|
- Tensile Strength Test at Defined Elongation
|
Extended Applications (Additional Accessories Required) |
- Puncture Test of Hypodermic Needles in Artificial Skin
|
|
- Puncture Test of Infusion Bags
|
- Puncture/Pullout Test of Flexible Rubber Closures
|
- Opening Resistance Test of Combined Covers
|
- Tear Test of ZD - Type Caps
|
- Opening Force Test of Oral Liquid Caps
|
- Puncture/Pullout Test of Oral Liquid Caps
|
- 90 Degree Pullout Test of Infusion Bag Caps
|
- Pullout Test of Infusion Bag Caps
|
- 23 Degree Pullout Test of Bottle Caps
|
- Puncture/Pullout Test of Bottle Caps or Rubber Closures
|
- 90 Degree Peel Test of Adhesive Tapes
|
- Tear Resistance Test of Adhesive Binding Books
|
- 90 Degree Peel Test of Water-soluble Plasters
|
- Tear Resistance Test of Adhesives
|
- Adhesive Strength Test (soft)
|
- Adhesive Strength Test (hard)
|
- Peel Test of Flexible Tube Caps
|
- Removal Force of Pipes and Pipe Joints
|
- Pullout Test of Cosmetic Brush Hair
|
- Pullout Test of Tooth Brush Hair
|
- Tensile Strength of Ropes at Break
|
- Opening Force Test of Jelly Cups and Yogurt Cups
|
|
|
- Pullout Test of Rubber Stoppers
|
- 45 Degree Peel Test of Bottle Membranes
|
- Tensile Strength of Sealing Bags
|
- Peel Test of Magnetic Cores
|
- 90 Degree Peel Test of Magnetic Cards
|
- Tear Resistance of Heat Sealing Films
|
- Separating Force of Protection Films
|
- Peel Test of Release Paper
|
- Tear Test Using Trouser Method
|
- Unwrapping Force of Adhesive Tapes
|
- Compressive Resistance of Plastic Bottles
|
|
|
- 135 Degree Peel Test of Plugs
|
- Peeling Grips of Floating Rollers
|
|
|
|
|
|
|
- Tensile Strength of Contact Lenses at Break
|
- Compression Resistance of Jelly Cups
|
- Compression Resistance of Package
|
- Compression Resistance of Sponge
|
|
Technical SpecificationsNote2
| Specifications |
C610H Auto Tensile Tester |
| Load Cell Capacity |
500 N (standard) 50 N, 100 N, 250 N, 1000 N (optional) |
| Accuracy |
0.5% of indicated value (2%FS100%FS) 0.01%FS (0% 2%FS) |
| Resolution |
0.001 N |
| Test Speed |
0.05 500 mm/min |
| Speed Accuracy |
0.5% of indicated value (1%100% of maximum speed) |
| Number of Specimens |
1 |
| Specimen Width |
30 mm (Standard Grip) |
| 50 mm (Optional Grip) |
| Clamping Way |
Pneumatic Specimen Clamp |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 Mpa (72.5psii101.5psi) |
| Stroke |
1000 mm |
| Instrument Dimension |
500 mm (L) 520 mm (W) 1900 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
110 kg |
Configurations
- Standard Configurations
- Instrument, Professional Software, Tablet, Pneumatic Sample Grips
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Customized Grips, Laser Printer, Air Compressor, Computer System required by GMP, DataShieldTM Note3
- Note
- 1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Outstanding Precision and VersatilityEngineered with universal adjustable clamps and a sensitivity of 0.01 N, this tester adapts to diverse sample sizes up to 300 mm wide. The flexibility to store up to 99 test profiles simplifies recurring test routines for containers and flexible bags. It ensures repeatable results with a standard deviation no greater than 1%. Digital touch screen controls and pre-set programs deliver seamless operation for lab professionals.
Comprehensive Data Management and ReportingTest results are easily exported in CSV or PDF formats via USB, RS232, or Ethernet connectivity. The instrument's customizable test report templates and inbuilt auto data-logging streamline documentation. With password-protected user levels and programmable test cycles, sensitive data integrity and efficient workflow management are assured across testing cycles.
Enhanced Safety, Connectivity, and ComplianceSafety is integrated through peak hold and audible alarms, plus overload protection. The unit operates quietly below 65 dB(A), making it suitable for shared lab environments. Users benefit from multi-language menu navigation, automatic/manual calibration, and included operation manual-ideal for global quality assurance teams.
FAQ's of Testing for Quantifying Opening Easiness in Containers and Flexible Bags:
Q: How does the Opening Force Tester quantify the easiness of opening containers and flexible bags?
A: The tester quantifies opening easiness by applying controlled tensile, peel, or open force using its stepper motor drive. It measures the resistance of packaging materials, providing data on the force required to open, which helps optimize packaging design and ensures compliance with industry standards.
Q: What is the process for setting up and running a test?
A: To start, secure the specimen-up to 300 mm wide-using universal adjustable clamps. Select or program a test profile via the touch screen. Adjust the test speed (10-200 mm/min), force range, and testing mode. Once parameters are set, initiate the test. Results are displayed in real time and can be saved or exported for further analysis.
Q: When should calibration be performed, and how is it handled?
A: Calibration should be performed regularly or prior to critical testing cycles to ensure continued accuracy. The tester supports both automatic and manual calibration modes, which can be initiated through the digital menu. Refer to the included operation manual for step-by-step instructions.
Q: Where can the test data be exported and in what formats?
A: Test data is easily exported through USB, RS232, or Ethernet connections, supporting CSV and PDF formats. This facilitates seamless integration with laboratory information systems and straightforward sharing of results with quality assurance or production teams.
Q: What are the benefits of using programmable test cycles and pre-set profile storage?
A: Programmable test cycles and storage of up to 99 profiles streamline recurring testing tasks, minimizing setup time and reducing errors. This automation ensures reproducibility, enhances laboratory efficiency, and aids in maintaining compliance with standardized procedures.
Q: How does password protection and multi-language support improve usage in diverse laboratory environments?
A: Password-protected user levels safeguard data integrity and restrict unauthorized access, while multi-language interface options make operation intuitive for international teams, improving efficiency and reducing the risk of user error in global organizations.