Product Description
Product Featuresnote1
OTR/WVTR tested in One Instrument
- OTR \ WVTR mode, OTR mode and WVTR mode are available for selection.
- OTR and WVTR tests can be automatically completed for each sample mounting.
- Genuinely reflect the OTR \ WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.
Coulometric Oxygen Sensor
- The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
- Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
- Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
- Over limit alarm and automatic protection.
Infrared Moisture Sensor
- The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
- Designed according to ASTM F1249.
- Longer service life, non-consumable.
- Over limit alarm and automatic protection.
Accurate Data
- Using 360 air circulation constant temperature technology, the temperature stability is better.
- Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
- In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
- Higher test repeatability of 0.01 cc / (m2day) can be achieved.
High Efficiency Three-cell
- Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
- Three samples can be tested at the same time under the same conditions, with independent tests data.
- In the same test cycle, the number of samples completed increases from 2 to 3.
- Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.
Intelligent Operation
- The 12 Inch Touch panel of windows system is used for more convenient operation.
- Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
- New drawer type test cell, one key automatic in-and-out with sound and light reminder.
Safe and Reliable
- Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
- Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
- Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.
Powerful Functions
- Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
- Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
- Wide temperature range, allowing the barrier test at different temperatures (customized).
- The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).
Testing Principle
The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.
Reference Standards
ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015
Test Applications
| Applications |
- Films
The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
|
- Sheets
The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.
|
Technical Specifications
Table 1: Test Parameters Note2
| Parameter/Model |
Model C403H |
| OTR Test Range |
cc/(m2day) (Standard area 50cm2) |
0.01 200 |
| cc/(m2day) (MASK area 5cm2) |
0.2 2000 (Optional) |
| cc/(m2day) (MASK area 1cm2) |
1 10000 (Optional) |
| OTR Resolution |
cc/(m2day) |
0.0001 |
| OTR Repeatability |
cc/(m2day) |
0.01 or 1%, whichever is greater |
| WVTR Test Range |
g/(m2day) (Standard area 50cm2) |
0.005 40 |
| g/(m2day) (MASK area 5cm2) |
0.2 400 (Optional) |
| g/(m2day) (MASK area 1cm2) |
1 2000 (Optional) |
| WVTR Resolution |
g/(m2day) |
0.0001 |
| WVTR Repeatability |
g/(m2day) |
0.005 or 2%, whichever is greater |
| Temperature range |
C |
15 - 50 5 60 (Customized) |
| Temperature fluctuation |
C |
0.05 |
| Humidity range |
%RH (Within standard temperature range) |
0%, 5 - 902% |
| Extended functions |
GP-01 Gas Purification Unit |
Optional |
| DataShieldTM Note3 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Test Chamber |
3 test chambers |
| Specimen Size |
4.4 x 4.411.2cm11.2cm) |
| Specimen Thickness |
120 Mil3mm |
| Standard Test Area |
50 cm2 |
| Carrier Gas |
99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope) |
| Carrier Gas Pressure |
40.6 PSI / 280 kPa |
| Port Size |
1/8 inch metal tubing |
| Power Supply |
120VAC10% 60Hz / 220VAC10% 50Hzeither one of two |
| Instrument Dimensions |
23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm) |
| Net weight |
220Lbs100kg |
Configurations
- Standard Configurations
- Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
- Optional Parts
- GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
- Remarks
- 1. The gas supply port of the instrument is 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.
Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.
Precision Testing for Sustainable Packaging SolutionsThis instrument delivers precise moisture barrier property assessments for biodegradable materials using the globally recognized gravimetric/dry cup method. Its high-resolution sensor system ensures accurate readings, vital for quality assurance in eco-friendly packaging. With programmable testing conditions, researchers and manufacturers can simulate various environments to validate compliance and optimize material performance.
Flexible and Automated Operation for High ThroughputDesigned for continuous, high-volume testing, the equipment allows simultaneous analysis of up to 3 samples, enhancing productivity in R&D or quality control labs. Automated digital controls, external automatic calibration, and real-time data storage facilitate seamless operation, making it accessible for both laboratory and industrial applications.
Comprehensive Support and Robust Export StandardsSupplied in export-grade wooden packaging, and backed by onsite, remote, and telephonic service, the instrument ensures reliable global operation. Its construction meets international and ASTM standards, guaranteeing consistent results. Built with industrial-grade durability, its suited for dealers, exporters, fabricators, and suppliers targeting high-precision moisture analysis in biodegradable packaging.
FAQs of Testing Instrument for Moisture Barrier in Biodegradable Packaging:
Q: How does the instrument measure moisture barrier properties in biodegradable packaging?
A: This instrument uses the gravimetric/dry cup method as specified by ASTM E96. It measures the water vapor transmission rate (WVTR) of packaging materials by evaluating the weight change as moisture passes through the test specimen under controlled humidity and temperature conditions.
Q: What materials are compatible with this moisture barrier tester?
A: The tester is compatible with a range of biodegradable materials, including bio-polymer films, paper-based packaging, PLA, PHA, and starch blends. Its designed for contemporary packaging research and industrial quality assurance.
Q: When and why should I calibrate the instrument, and how is it performed?
A: Regular calibration ensures consistent accuracy for long-term use. This instrument features an external automatic calibration facility, minimizing downtime. Calibration should be carried out during initial setup, after maintenance, or when accuracy verification is required, following prompts from the microprocessor control system.
Q: Where is the test process conducted and what are the ambient requirements?
A: The testing process is performed in the instruments 10-liter specimen chamber, which can accommodate up to three samples. Ambient requirements include a temperature between 10C and 35C under non-condensing conditions, with programmable humidity from 10% to 90% RH.
Q: What are the advantages of using this equipment for laboratory or industrial applications?
A: The instrument offers high accuracy (0.01 g/m24h), rapid response time (<5 seconds), and automated, programmable testing. Its data connectivity, robust alarm systems, and export-quality packaging make it suitable for both research and industrial environments seeking reliable moisture barrier assessment.
Q: How is test data managed and output from the instrument?
A: Test data can be digitally displayed via an LCD screen, stored in its microprocessor memory, and exported through USB, RS232, or directly to a printer via the integrated port, enabling flexible data handling and reporting.
Q: What level of support is available for installation and operation?
A: Comprehensive support is available via onsite visits, remote assistance, and telephonic guidance, ensuring smooth installation, operation, and troubleshooting for users worldwide.