Product FeaturesNote1
Multiple Test Modes & Intelligent Statistics of Qualified Specimens
- Negative pressure method
- Multiple test modes including standard, multi-grade vacuum and methylthionine chloride mode
- Automatic test with traditional methylthionine chloride
- Vacuum degree, test time and infiltration time can be adjusted and test parameters can be saved automatically so that the tests with same test parameters can be started quickly
- Automatic constant pressure compensation ensures that the tests can be performed under preset vacuum conditions
- Real-time display of test curves, easy to observe the test results
- Automatic statistics of qualified specimens
- Main components and parts are supplied by well-known global manufacturers, with guaranteed performance
Brand New Patented Intelligent Touch Operating System
- Industrial grade touch screen, one-button operation, simplified operating interface, remote upgrade and maintenance
- Chinese and English operating interface
- Measurement unit conversion
- Automatic data storage and power failure memory to prevent data loss
- Storage up to 1200 test records (standard mode)
- Multiple-level user management and login with password
- Micro-printer and USB ports for data transmission (optional)
- The instrument conforms to the requirements of GMP (optional)
- Labthinks unique DataShiledTM System for data management and connecting with information system (optional)
Test Principle
Firstly submerge the specimen in the water in the vacuum chamber, and then evacuate the vacuum chamber to form differential pressure between the inside and outside of specimen. The seal property can be obtained by observing the steady progression of bubbles from the specimen or observing how the specimen expands and restores to its original shape after vacuum release.
Test StandardNote1
ASTM D3078, GB/T 15171
Applications
| Basic Applications |
- Glass Bottles, Pipes, Cans and Boxes
|
- Plastic Bottles, Pipes, Cans and Boxes
|
- Metal Bottles, Pipes, Cans and Boxes
|
- Paper Plastic Composite Bags and Boxes
|
| Extended Applications |
|
|
|
|
|
|
Technical Specifications
| Specifications |
C660B |
| Vacuum Degree |
0 -90 KPa/ 0 -13 psi |
| Accuracy |
0.25% FS |
| Resolution |
0.1 KPa / 0.01 psi |
Vacuum Chamber Effective Sizes |
I270 mm x 210 mm (H) (standard) |
| I360 mm x 585 mm (H) (optional) |
| I460 mm x 330 mm (H) (optional) |
| Note: customization is available for other sizes |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 Mpa (73psi 101psi) |
| Instrument Dimension |
334 mm (L) x 230 mm (W) x 170 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
Instrument: 6.5 kg Standard Vacuum Chamber: 9kg |
Configurations
- Standard Configurations
- Instrument, Standard Vacuum Chamber (I270 mm x 210 mm), I6 PU Tubing (1m)
- Optional Parts
- Micro Printer, Professional Software, Customized Vacuum Chamber, Air Compressor, GMP System, DataShieldTM Note3
- Note
- 1. The gas supply port of the instrument isI6 mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Precision Leak Detection for Packaging IntegrityThis instrument utilizes vacuum decay technology to identify even minute leaks in packaging, ensuring product safety for food and medicine. Designed with a transparent acrylic chamber for clear observation and a stainless steel structure for durability, it permits traceable, repeatable testing with exceptional accuracy.
User-friendly Control and Data ManagementNavigating the digital control panel is straightforward, and the machine's automation grade streamlines test cycles. Data can be stored internally for up to 100 tests and easily exported via USB or RS232 interface, making record-keeping and result sharing highly efficient.
Enhanced Safety and Reliable PerformanceIntegrated over-pressure protection, an emergency stop button, and alarm systems ensure operational safety. The instrument supports both automatic and manual calibration, guaranteeing precise measurements and dependable testing outcomes in any laboratory or production environment.
FAQ's of Air-tightness Test Instrument for Ensuring Food and Medicine Packaging:
Q: How does the air-tightness test instrument detect leaks in packaging?
A: The instrument employs the vacuum decay method, which involves reducing the chamber pressure and monitoring for changes in pressure. Any increase in pressure indicates a leak in the package under test, which is signaled by the built-in audio-visual alarm system.
Q: What types of packaging materials and sizes can be tested with this equipment?
A: The instrument can test a single package specimen up to 300 x 300 mm in size and up to 350 mm chamber height, covering a wide range of food and medicine packaging materials commonly used by manufacturers and exporters.
Q: When should I calibrate the machine, and can this be done automatically?
A: Calibration should be performed routinely or whenever the accuracy of results is in question. The equipment supports both manual and automatic calibration modes, allowing users to select based on their operational preferences and requirements.
Q: Where can this instrument be installed and used most effectively?
A: Designed as a tabletop model, the instrument is suitable for laboratories, quality control departments, or production lines within food and pharmaceutical manufacturing facilities. Its semi-automatic operation and moderate machine weight ensure easy placement and portability.
Q: What is the process for conducting an air-tightness test using this device?
A: To conduct a test, place the specimen inside the acrylic chamber and close the lid. Set the test parameters on the digital control panel. The instrument will automatically regulate vacuum and monitor pressure decay, displaying results on the LCD screen and saving data for up to 100 tests.
Q: How is data handled and exported with this testing instrument?
A: The device can store up to 100 records internally, which users can export through USB or RS232 ports. This makes data transfer to external devices or integration with laboratory information management systems efficient and straightforward.
Q: What are the benefits of using this air-tightness test instrument for packaging applications?
A: Using this instrument ensures the integrity of food and medicine packaging, reduces risk of contamination, and safeguards product quality. Its fast response time, high accuracy, and comprehensive safety features make it ideal for compliance, quality assurance, and streamlined manufacturing processes.