Product Description
High Precision
- Patented test chamber and test dishes with advanced fluid dynamics and thermodynamic designs.
- Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
- Precise and scientific regulation and calculation of testing conditions.
High Efficiency
- 12 test stations
- Supports test modes of desiccant method and water method
Labor Saving
- Automatic humidity and flow rate controlling.
- Desiccator requires no replacement of inner core.
- High-efficiency water vapor generator.
Simplified Operation
- 12 touch-screen pad powered by WindowsTM 10 operating system
- Fast automatic testing process
- Optional DataShieldTM software and accessories for automatic data management
Product Features
New Generation Test Chamber and Test Dishes
Patented test chamber and test dishes with advanced hydrodynamic and thermodynamic designs ensure the uniform flow rate over the specimen surface, stable temperature and humidity, creating a uniform and stable testing environment. As a result, the test duration is shortened and the test results will be more accurate.
Excellent Testing Abilities of High and Low Barrier Materials
The testing conditions will be regulated precisely in real time, which ensures the high testing accuracy and repeatability of high and low barrier materials.
Automatic Controlling of Temperature, Humidity and Air Velocity
Labthinks proprietary thermostat technology ensures that the test chamber is precisely temperature controlled and remains stable throughout the test.
Air velocity is monitored and regulated in real time.
High-efficiency and mist-free automatic humidity regulator meets the requirements for long-term continuous tests.
It is unnecessary to replace the inner core of the desiccator, which can continuously work for 20,000 hours.
Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system facilitates centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.
User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.
Test Principle
The test specimen is mounted in the test dish which contains water or desiccant inside. The test dish is placed in the test chamber with stable temperature, humidity and air flow. The water vapor permeates through the specimen and into the dry side. By measuring the weight changes of the test dish periodically, water vapor transmission rate and other parameters can be obtained.
Test Standards
ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, GB/T 1037, GB/T 16928, YBB 00092003-2015
Applications
| Basic Applications |
- Films
Plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminum coated films, aluminum foil composite films, glass fiber aluminum foil paper composite films and many other film materials
|
- Sheeting
PP, PVC and PVDC sheeting, metal foils, rubber pads and other sheeting materials
|
- Paper and Paper Board
Aluminum coated paper for cigarette, paper aluminum plastic composite film and other paper and paperboards
|
- Textiles and Nonwovens
Textiles and nonwoven fabrics
|
| Extended Applications |
- Construction Materials
Geotextiles, felt, roofing and building materials, vapor barrier membranes, etc.
|
- Aseptic Wound Protection Films and Medical Plasters
Aseptic wound protecting films, medical plasters and protective clothing materials
|
Technical Specifications
Table 1: Test Parameters Note1
| Parameter |
Model C360H |
| Testing Efficiency |
0.01g/(m2day) 0.5g/(m2day) |
>24 hours |
| 0.0006g/(100in2day) 0.0323g/(100in2day) |
| 0.5 g/(m2day)5 g/(m2day) |
12 24 hours |
| 0.0323g/(100in2day) 0.3225g/(100in2day) |
| > 5 g/(m2day) |
12 hours |
| > 0.3225 g/(100in2day) |
| Max. Test Range |
Water Method |
10000/ni141-12i14g/(m2day) |
| 645/ni141-12i14g/(100in2day) |
| Desiccant Method |
1200g/(m2day) per piece |
| 77g/(100in2day) per piece |
| Test Station |
|
12 |
| Test Temperature |
C |
20 55 0.2 |
| Test Humidity |
RH |
10% 90% 1% |
| Additional Functions |
DataShieldTM Note2 |
Optional |
| Computer System required by GMP |
Optional |
| CFR21 Part11 |
Optional |
Table 2: Technical Specifications
| Specimen Size |
I74mm |
| Specimen Thickness |
3mm |
| Test Method |
Desiccant Method / Water Method |
| Standard Test Area |
33cm2 |
| Carrier Gas |
Compressed Air |
| Drying of Carrier Gas |
Long Service-life Desiccator (unnecessary to replace inner core) |
| Humidifying of Carrier Gas |
High-efficiency mist-free humidity generator |
| Carrier Gas Pressure |
0.6 MPa |
| Port Size |
I6mm PU Tubing |
Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.
Advanced Dual-Mode TestingThis system features both gravimetric (weight loss) and precision sensor-based test modes for tackling diverse measurement requirements. The selectable modes allow for versatile operation, making it ideal for businesses needing to analyze various polymer waterproof coil batches with high reproducibility and accuracy.
Intelligent Data ManagementThe integrated memory can store up to 200 sets of test data, ensuring no data loss during extensive testing runs. Automatic data recording and fast digital LCD display facilitate efficient result retrieval and analysis, optimizing workflow in busy laboratory settings.
Built for Durability and PrecisionConstructed with corrosion-resistant stainless steel, the testing chambers ensure longevity and consistent performance even under high humidity conditions. The microprocessor-based control provides precise, automatic regulation of test parameters for reliable, repeatable outcomes.
FAQ's of Essential Water Vapor Barrier Testing System for Polymer Waterproof Coil:
Q: How does the Essential Water Vapor Barrier Testing System operate?
A: The system functions by placing polymer waterproof coil specimens in its chambers and utilizing gravimetric (weight loss) or precision electronic balance sensor modes to measure water vapor transmission rates. The operation is managed automatically by an integrated microprocessor, ensuring accurate and stable test conditions.
Q: What types of specimens can be tested, and in what quantity?
A: It is designed specifically for polymer waterproof coil specimens with a standard diameter of 80 mm. The system supports simultaneous testing of 1-3 specimens, making it efficient for comparative and repeatability analysis.
Q: When should calibration of the system be performed?
A: Calibration should be performed before initial use and periodically per laboratory quality standards. The system supports both automatic and manual calibration to maintain test accuracy and compliance with testing protocols.
Q: Where can this water vapor barrier testing system be used?
A: This equipment is intended for indoor laboratory use in non-corrosive environments. Its robust, tabletop-mounted design and corrosion-resistant chamber make it suitable for research, quality control, and manufacturing labs handling polymer waterproof materials.
Q: What is the testing process and how are environmental conditions regulated?
A: Specimens are placed inside the stainless steel chambers where temperature (15-50C) and humidity (up to 95% RH) are set via the digital interface. The automated control system maintains these parameters throughout the duration of the test, with adjustable test speed and stroke for flexibility.
Q: How does automatic data storage benefit laboratory testing?
A: With a capacity to store up to 200 test sets, the system eliminates manual data entry errors, streamlines result management, and ensures quick data retrieval for analysis and reporting-all of which speed up workflow and improve data integrity.
Q: What are the advantages of using the system for polymer waterproof coil testing?
A: Users benefit from precise, reliable measurement of water vapor permeability over a wide range (0.01-10,000 g/m224h) with 2% accuracy. The automatic operation, durability in high humidity, and compatibility with Windows PC software make it an efficient, long-lasting solution for material analysis and quality assurance.