Product Description
Featuresnote1
Batch Testing
- Equipped with fully-automatic gravity fed sample feeder, which is Labthinks latest scientific and technological achievement that can facilitate continuous testing of 20 to 120 samples.
- A & B dual-channel design can test samples of two different specifications simultaneously.
- The target vacuum degree can be set by the operator to meet testing requirements of different samples.
- Dual methods of vacuum decay and pressure decay provide the flexibility to accommodate various types of package samples.
Precise Data
- Advanced pressure detection technology, using world renowned components for data stability which is not affected by ambient environment.
- Advanced microflow automatic flow control technology that can accurately simulate different sizes of leakage holes without manual adjustment.
- Both the differential pressure transducer and flow meter are traceable to NIST.
- The system can achieve a higher test repeatability of 1um.
Intelligent Control
- 15.6" embedded touch tablet computer with Windows OS.
- New longitudinal interface layout, and easy to use graphic user interface.
- Automatic alarm, automatic capture, automatic collection of unqualified samples.
- The pressure curve is displayed in real time, and the test results are counted automatically.
- Leakage rates are calculated automatically.
- The system is equipped with various sensors as intelligent reminders for safer operation and control.
- Universal printer can be connected for test results output.
- The system features embedded with USB and network ports to facilitate the external access and data transmission of the system, which can be upgraded remotely
Security Compliance
- Verified by compensation and calibration methods.
- The leak tester meets GMP requirements for data traceability and meets the needs of the pharmaceutical industry.
- User operation permission is managed at multiple levels, and the permission content can be configured on demand.
- Electronic signature is designed according to the standard requirements of 21 CFR Part11.
Test Principle
The sample is placed in the sample feeder and automatically delivered into the test cell. The leak rate and other results can be calculated and obtained by analyzing pressure changes measured by the sensor.
Reference Standards
ASTM F2338, YY-T 0681.18, and USP<1207>
Applications
| Basic Applications |
Vials |
Various vial sealing test. |
| Extended Applications |
Ampoule |
Various ampoule bottle sealing tests. |
| Cartridge Bottles |
Various cartridge bottle sealing tests. |
| Injection bottles |
Various injection bottles sealing test. |
Technical Parameters
Table 1: Test Parameters Note2
| ParameterModel |
C690H |
| Testing Range |
um(Reference aperture size USP1207) |
3i8igreat leakage |
| Detection Lower Limit |
um |
3 |
| Resolution |
um |
0.1 |
| Repeatability |
um |
1 |
| Pressure Range |
kPa |
-100i0ii14100 |
| Extended Functions |
21 CFR Part11 |
Optional |
| GMP computer system requirements |
Optional |
Table 2: Technical Specifications
| Testing Cell |
1 set for A group and 1 set for B group |
| Sample Feeder |
1 set for A group and 1 set for B group |
| Sample Size |
I45 mm80mmNote3 |
| Sample Quantity |
20120 pieces |
| Gas Specifications |
Compressed Air (Gas source is provided by the user) |
| Gas Source Pressure |
40.6 PSI / 500 kPa |
| Port Size |
I6 mm Polyurethane tube |
| Dimensions |
33.4 H x 19.6 W x 28.7 D (85cm 50cm 73cm) |
| Power |
120VAC10% 60Hz / 220VAC10% 50Hzi14select one from the twoi14 |
| Net weight |
209Lbs (95kg) |
Product Configuration
| Standard Configuration |
Mainframe, embedded tablet computer, software, flow meter, European vacuum pump, I6 mm polyurethane tube |
| Customization |
Test cell and sample feeder of group A, test cell and sample feeder of group B, negative standard reference sample and positive standard reference sample designed according to sample specifications |
| Optional Parts |
GMP computer system requirements, 21 CFR Part11, air compressor, IQ/OQ/PQ documents |
Note 1: The described product characteristics are subject to the specific annotation of the "Technical Parameters" table.
Note 2: The parameters in the table are measured in the Labthink laboratory by professional operators according to the requirements and conditions of the relevant laboratory environmental standards.
Note 3: Group C test cell can be customized for samples beyond the "Sample Size", but the lower detection limit and test range will change according to the sample size, and the actual delivery shall prevail.
Advanced Non-Destructive Leak Testing TechnologyUtilizing vacuum decay and differential pressure methods, this leak detection solution delivers highly repeatable, non-destructive assessments for electronic packaging. Suitable for a variety of tray and packaging materials, it ensures component safety while maximizing throughput and minimizing downtime.
Seamless Integration and Easy OperationEquipped with a color LCD touch screen and intuitive software interface, users can monitor, analyze, and manage test results effortlessly. The system supports both single and batch testing modes, with programmable controls, internal memory, USB export, and multiple communication ports for seamless workflow integration.
Robust Safety and Data Management FeaturesIntegrated over-pressure protection, visual and audible alarms, error diagnostics, and both automatic and manual calibration secure safe operation. Data is stored internally and can be exported via USB, allowing efficient traceability and compliance with stringent quality standards.
FAQ's of Non-Destructive Electronic Component Packaging Leak Detection Solutions:
Q: How does the non-destructive electronic component packaging leak detection system work?
A: The system uses vacuum decay or differential pressure methods to detect leaks in IC and electronic component trays without damaging the packaging. It measures minute pressure changes caused by leaks, delivering precise and quantitative results within as little as five seconds.
Q: What types of packaging and materials can be tested with this solution?
A: The solution is compatible with a range of test materials including plastic, metal, and composite IC and component trays. It accommodates specimen sizes up to 320 x 260 x 120 mm, making it versatile for different packaging applications.
Q: When is calibration required and how is it performed?
A: Calibration can be set to automatic or manual, depending on user preference or regulatory requirements. Calibration ensures ongoing measurement accuracy and can be accessed and managed directly through the color LCD touch screen interface.
Q: Where is the data stored and how can it be accessed for analysis?
A: Test data are stored internally within the system and can be quickly exported via USB for backup or deeper analysis. Additionally, PC software supported by the system allows comprehensive data evaluation and trend monitoring.
Q: What is the process for conducting a leak test?
A: Place the specimen tray on the pedestal (approx. 250 x 300 mm), configure the test using the touch screen, ensure the test medium (dry/inert gas) is set, and start the automatic or manual cycle. The microprocessor-based programmable controller then handles the leak detection process, providing results and alarms as configured.
Q: How does the system enhance safety during operation?
A: The leak detection equipment is built with over-pressure protection, error diagnostic capabilities, and uses EPDM/Silicone sealing to prevent contamination. Visual and audible alarms notify users immediately if a leak or fault is detected, ensuring operator and product safety.
Q: What are the benefits of using this quantitative leak detection system?
A: Manufacturers benefit from rapid, accurate, and non-destructive testing, reducing scrap and rework costs while ensuring packaging integrity. Adjustable cycle times, batch testing, and robust data management streamline quality control for high-volume production environments.