Call Us
Send Inquiry    Call Me Free
C830H Migration and Non-volatile-matter Content Tester

C830H Migration and Non-volatile-matter Content Tester

50000 USD ($)/Set

Product Details:

  • Accuracy 0.2 mg
  • Response Time < 3 seconds
  • Power Supply AC 220V, 50Hz
  • Interface Type RS232
  • Specimen Size 110 mm 50 mm
  • Application Measurement of migration and non-volatile content in plastics, rubber, and packaging materials
  • Display Type LCD touch screen
  • Click to View more
X

C830H Migration and Non-volatile-matter Content Tester Price And Quantity

  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Cubic Centimeter

C830H Migration and Non-volatile-matter Content Tester Product Specifications

  • Testing migration/residual matter in packaging
  • 0 ~ 300
  • 0.6 MPa
  • 50 Hz
  • 6 mm gas port
  • AC 220V 10%
  • Automatic
  • 45% ~ 75% RH
  • 1 ~ 3
  • 0.1 mg to 1000 mg
  • About 16 kg
  • Room temperature to 300
  • Migration and Non-volatile-matter Content Tester
  • Measurement of migration and non-volatile content in plastics, rubber, and packaging materials
  • 110 mm 50 mm
  • LCD touch screen
  • Microcomputer automatic control
  • 100 mm
  • Desktop
  • 0.01 mg
  • Automatic temperature control, Over-temperature protection, Touch screen operation
  • 210 mm
  • < 3 seconds
  • AC 220V, 50Hz
  • RS232
  • 150 mm
  • 2 L
  • 0.2 mg
  • 50 mm/min

Product Description

Features

Professional

As an innovator and leading manufacturer, Labthink is dedicated to development of testing instrument for determination of migration and non-volatile contents, which is highly-integrated, automatic, precise and harmless.

  • Integrated testing process with evaporation, drying and weighing all-in-one instrument, which can be used for determination of migration and non-volatile contents with trichloromethane, acetic acid, ethanol, n-hexane and many other reagents.
  • Harmless testing process. The evaporated reagent will be collected and processed through special gas pipes, without requiring additional gas handling systems in laboratory.
  • High efficiency reagent recycling function makes it possible to recycle 90% Note1 of n-hexane without introducing extra foreign matters (e.g. bath water).
  • The testing process is automatic without human intervention, which can protect the operators from the hazardous gases and guarantee the safety of operators.
  • Automatic testing process. With precise automatic weighing system, operating errors can be minimized and constant weight can be obtained effectively.
  • Precise testing process. Specially designed constant temperature chamber and weighing system can guarantee the testing accuracy.

High Efficiency

High-efficiency and automatic design minimize the human operation. With advanced technology, the instrument supports simplified test method, testing process and combination of tests.

  • Worlds leading fast evaporation technology can reduce the evaporation time by heating the reagent to the status most close to boiling.
  • The test chamber can be opened and shut automatically. The airtight test chamber makes the operation safe and simplified.
  • With gas balancing technology, the concentration of evaporated reagent can be reduced quickly, which improves the evaporation efficiency and operating safety.
  • The testing process is efficient with flexible and professional process parameters as well as multiple test modes including proportional mode, standard mode, differential mode and fast mode, etc.
  • The instrument is equipped with 9 working stations, with independent test parameters, process data and test results.
  • Labthinks exclusive extended working station mode (optional) supports 9 to 90 stations of multiple testing instruments Note3.

Intelligent

The instrument is embedded with Labthinks latest operating software, which is featured with user-friendly interface, intelligent data processing, strict user management and secure data storage. It also supports Labthink exclusive DataShieldTM Note4 (Optional) which provides the users with safe and reliable management of test data and test reports.

  • Test data can be displayed in various forms including curves and data list
  • Test data will be saved and encrypted in a unique way so that all the test information will be saved securely and reliably and protected from being tampered
  • Various forms of test data can be searched, exported and printed out

Test Principle

Total Migration

The specimen shall be soaked in the solution which is simulator of various food. When the solution is evaporated to dryness, the total migration of non-volatile contents can be measured and calculated.

Non-volatile-matter Content

The specimen shall be soaked in standard reagent. When the reagent and blank liquid bath are evaporated to dryness, the total weight of non-volatile-matter contents can be obtained by comparing with the blank liquid.

Test Standards

ISO 759-1981, GB 31604.8-2016, GB/T 9740-2008, YBB00342002-2015 and YBB00132002-2015, etc.

Applications

Basic Applications
  • Determination of migration of packaging materials for food and their products
    Determination of migration of food packages made of PE, polystyrene, PVC, PP, melamine, EPS and plant fiber, etc.
    Determination of migration of rubber gasket, sealing ring of pressure cooker, rubber nipple, rubber tubes in food industry.
    Determination of migration of coatings in the interior wall of food containers such as Vinylidene Chloride, epoxy novolac, Polyamide epoxy resin and PTFE, etc.
  • Determination of Non-volatile-matter Contents of packaging materials for pharmaceuticals
    Determination of non-volatile contents in transfusion bottles, eye drop bottles, oral liquid vials, oral medicine bottles, transfusion bags and their caps which are made of LDPE, HDPE, PP and PET, etc.
    Determination of non-volatile contents in compound films and bags made of PE, BOPP, VMCPP and PET, etc.
    Determination of non-volatile contents in compound rigid sheeting made of PVC, LDPE, PVDC and PA for medical use
    Determination of non-volatile contents in PE/Aluminum/PE compound tubes for ointment and LDPE films and bags.
    Determination of non-volatile contents in Halogenated butyl rubber closures for injection or injection powder
    Determination of non-volatile contents in medicinal gasket, rubber closure, piston and protective cap.

Technical Specifications

Table 1: Test Parameters Note1

Parameter Model C830H
Test Range mg 0.3 80000
Resolution mg 0.1
Repeatability mg 0.3
Test Temperature C Room Temperature 130
Temperature Accuracy C 0.5
Additional Functions Fast Evaporation Mode Standard
Reagent Recycling Function Standard
Acid, Alcohol & Alkane Test Standard
Extended Working Station Optional
DataShieldTM Optional

Table 2: Technical Specifications

Number of Working Stations 9 stations with independent weighing systems, test parameters can be different from each other, test data is independent, Customization Available
Test Cup Capacity 200ml, Customization Available
Gas Supply Compressed Air (Power Gas), High-purity Nitrogen (99.999%, Balance Gas)
Note: The gas supply is not in supply scope.
Gas Supply Pressure 0.6MPa
Port Size 6mm PU Tubing



Intelligent Control and Precise Measurements

Equipped with microcomputer automatic control and advanced PID temperature regulation, the C830H tester delivers accurate, repeatable results for migration and non-volatile content analysis. Its LCD touchscreen interface streamlines the testing process for operators, while the rapid response ensures efficiency in laboratory workflows.


High Storage Capacity and Flexible Testing

With the ability to store up to 200 test results and accommodate 1 to 3 specimens at a time, this tester supports large-scale and batch testing needs. The programmable timer allows flexible operation for up to 300 minutes, and its stainless steel chamber provides durability and reliability in various laboratory environments.


Safety-Oriented and User-Friendly Design

Overcurrent and overtemperature protections safeguard both users and equipment. Its automatic/manual calibration modes, touch screen operation, and desktop mounting enhance user convenience. Designed for ease of use, the C830H promotes stable and safe testing under ambient temperatures from 10C to 40C.

FAQ's of C830H Migration and Non-volatile-matter Content Tester:


Q: How does the C830H ensure accurate temperature control during testing?

A: The C830H uses an intelligent PID temperature control system that actively regulates heating to maintain stable and precise test conditions. This guarantees accurate results when assessing migration or non-volatile content within the desired temperature range (room temperature to 300C).

Q: What are the benefits of the automatic calibration feature in this tester?

A: Automatic calibration minimizes human error and simplifies setup, ensuring consistent measurement accuracy (0.2 mg) across multiple tests. Users can also opt for manual calibration for customized adjustments and compliance with specific laboratory protocols.

Q: When should I use the programmable timer function, and how long can it operate?

A: The programmable timer allows users to set test durations based on specific material requirements, supporting test times up to 300 minutes. This function is particularly useful for lengthy migration analyses where controlled timing is essential for reproducible outcomes.

Q: Where is the C830H typically used and what materials can it test?

A: The device is commonly utilized in quality control labs, research institutions, and manufacturing facilities. It is designed for measuring migration and residual non-volatile matter in plastics, rubber, and diverse packaging materials as per industry and regulatory standards.

Q: What is the process for storing and accessing historical test results?

A: Test results are automatically saved within the device's memory, which accommodates up to 200 entries. Users can review stored data via the LCD touch screen, streamlining analysis, reporting, and quality traceability.

Q: How does the safety system protect users and the equipment during operation?

A: Integrated overcurrent and overtemperature protection mechanisms monitor operating conditions continuously, shutting off power or alerting users if any unsafe thresholds are detected. This robust system ensures operator safety and equipment longevity during intensive testing procedures.

Q: What advantages does the touch screen display provide in daily operation?

A: The LCD touch screen facilitates easy navigation, real-time monitoring, and instant input of parameters, improving user experience and efficiency. It enhances precision by enabling direct control of settings and quick access to stored data.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Migration & Non-volatile-matter Content' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.