Call Us
Send Inquiry
Labthink C303H Water Vapor Transmission Rate Test System for Silica Gel Pads

Labthink C303H Water Vapor Transmission Rate Test System for Silica Gel Pads

50000 USD ($)/Set

Product Details:

  • Application WVTR measurement of silica gel pads and films
  • Display Type 7-inch color touchscreen
  • Test Range 0.01 1000 g/(m24h)
  • Accuracy 0.01 g/(m24h)
  • Operating Voltage AC 220V 10%, 50Hz
  • Humidity Up to 100% RH controlled chamber
  • Automation Grade Automatic
  • Click to View more
X

Labthink C303H Water Vapor Transmission Rate Test System for Silica Gel Pads Price And Quantity

  • 50000 USD ($)/Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 1 Cubic Centimeter
  • Coulometric/infrared sensor method (dry method)
  • 5C 35C, relative humidity 80%
  • Dry nitrogen or specified carrier gas
  • C303H
  • ASTM F1249, ISO 15106-2, JIS K7129 standards
  • Overpressure, overcurrent, leakage protection features
  • Automatic report generation in multiple formats
  • Integrated audible/visual warning system
  • Corrosion-resistant stainless steel
  • Sealed chamber, quick-clamp type
  • Multi-point calibration with traceable standards

Labthink C303H Water Vapor Transmission Rate Test System for Silica Gel Pads Product Specifications

  • Bench-top/Lab table
  • 480 mm
  • 0.6 MPa (max)
  • Real-time analysis
  • 0.001 g/(m24h)
  • Up to 1000 g/(m24h)
  • 74 mm
  • Standard gas connection ports
  • 3 (simultaneous testing)
  • 220V AC, 50Hz
  • Multi-chamber, high sensitivity, automatic flow adjustment
  • Water Vapor Transmission Rate Test System
  • 15C 55C adjustable
  • USB, Ethernet
  • Single phase, 50/60Hz
  • High throughput automation
  • 0.01 g/(m24h)
  • 0.01 1000 g/(m24h)
  • 7-inch color touchscreen
  • Permeation testing for silica gel pads, films, and packaging
  • Approx. 80 kg
  • WVTR measurement of silica gel pads and films
  • Automatic
  • AC 220V 10%, 50Hz
  • Up to 100% RH controlled chamber
  • Microcomputer controlled, touchscreen interface
  • Standard, automatic continuous measurement
  • Coulometric/infrared sensor method (dry method)
  • 5C 35C, relative humidity 80%
  • Dry nitrogen or specified carrier gas
  • C303H
  • ASTM F1249, ISO 15106-2, JIS K7129 standards
  • Overpressure, overcurrent, leakage protection features
  • Automatic report generation in multiple formats
  • Integrated audible/visual warning system
  • Corrosion-resistant stainless steel
  • Sealed chamber, quick-clamp type
  • Multi-point calibration with traceable standards

Product Description

Product FeaturesNote1

Infrared Moisture Sensor

  • The Labthink patented technology infrared moisture sensor can obtain lower test limit.
  • Designed according to ASTM F1249.
  • Long service life, non-consumable.
  • It has the functions of over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor for real-time monitoring and recording temperature and humidity changes.
  • In the test process, the automatic control of flow, temperature and relative humidity is realized, and the accuracy is higher.
  • It can achieve higher test repeatability of 0.005 g / (m2day) .

High Efficient Three-chamber

  • Independent three sets of 50cm2 standard area test chamber, in line with the standard requirements of parallel sample detection.
  • Three samples are tested at the same time under the same condition, and the data are independent of each other.
  • In the same test cycle, the testing number of samples completed increased from 2 to 3.
  • Automatic sample clamping, saving time and effort, realizing consistent clamping force and better sealing.

Intelligent Control

  • The 12 Inch Touch panel of Windows system is used to control, which is more convenient.
  • Automatic mode: input the test temperature and humidity, click one key to start the automatic test.
  • New drawer type test chamber, one key automatic in and out, sound and light reminder.

Safe and Reliable

  • Safe running: the unique high-end industrial computer of Labthink is embedded to eliminate the system failure caused by computer virus, and ensure the operation reliability and data storage security.
  • Safe operation: equipped with optical and other intelligent sensors, sound and light alarm and other intelligent alarms to ensure the safety of operation.
  • Safe Performance: the instruments are made of world famous brand components, stable and reliable.

Powerful Functions

  • Professional test mode provides flexible and rich control functions to meet the needs for scientific research.
  • Provide water vapor transmission curve, water vapor transmission coefficient curve, temperature curve, humidity curve.
  • Ultra wide test range, meet the barrier test of various materials. (Customized)
  • Ultra wide temperature range to meet the permeability tests at different temperatures. (Customized)

Testing Principle

The pre-treated sample is clamped between the test chambers, the nitrogen with stable relative humidity flows on one side of the film, and the dry nitrogen flows on the other side of the film; due to the existence of humidity difference, water vapor will diffuse from the high humidity side through the film to the low humidity side; on the low humidity side, the water vapor is carried to the infrared water sensor by the flowing dry nitrogen, and different water vapor is generated. The concentration produces different light signals, and the concentration value is obtained through analysis and calculation, and then the water vapor transmission rate of the sample is calculated.

Reference Standards

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The water vapor transmission rate tests of various plastic film, paper plastic composite film, co-extrusion film, aluminum plating film, aluminum foil composite film, glass fiber aluminum foil paper composite film and other film materials.
  • Sheet
    The water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Parameters

Table 1: Test Parameters Note2

Parameters/Model C303H
Test Scope g/(m2day) (standard area 50cm2) 0.005i40 (standard)
0.005100i14optionali14
g/(m2day) (MASK area 5cm2) 0.05400 (optional)
g/(m2day) (MASK area 1cm2) 0.252000 (optional)
Resolution g/(m2day) 0.0001
Repeatability g/(m2day) 0.005 or2%, whichever is greater
Temperature Range 15i50
560 (customized)
Temperature Fluctuation 0.05
Humidity Range %Rh (within standard temperature range) 5i901%
Extended Functions DataShieldTM Data Shield Note 3 Optional
GMP Computer System Requirements Optional
CFR21Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 sets
Sample Size 4.4 x 4.4i1411.2cm11.2cmi14
Sample Thickness 120 Mili143mmi14
Standard Test Area 50cm2
Carrier Gas Specification 99.999% high purity nitrogen (gas source is prepared by the user)
Air Source Pressure 40.6 PSI / 280 kPa
Interface Size 1 / 8 "metal tube
Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Power Supply 120VAC 10% 60Hz / 220VAC 10% 50Hz
Net Weight 220Lbsi14100kgi14

Table 3: Product Configuration

Standard Configuration Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm
Options Air compressor, CFR21Part11, GMP computer system requirements, DataShieldTM Data Shield Notes3
Note The compressed air inlet of the machine is I 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the user.

Note 1: the product features are subject to the specific notes in the "Technical Parameters" table.
Note 2: the parameters in the table are measured by professional operators in Labthink laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield system provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase it separately according to the usage.



Advanced Testing Technology

The C303H system features the dry method using coulometric and infrared sensors for real-time WVTR determination, ensuring quick and accurate detection for silica gel pads and related materials. Multi-point calibration with traceable standards guarantees reliable results.


User-Friendly Operation and Automation

With microcomputer control and a 7-inch color touchscreen, the C303H offers intuitive operation and supports high-throughput, automatic continuous measurement. Built-in data management, automatic report generation, and USB/Ethernet connectivity streamline workflow and result documentation.


Safety and Compliance Focused

The corrosion-resistant stainless steel chamber, integrated audible/visual alarms, and protections for overpressure, overcurrent, and leakage ensure safe operation. Full compliance with global testing standards assures trustworthy performance for manufacturers, exporters, and researchers.

FAQ's of Labthink C303H Water Vapor Transmission Rate Test System for Silica Gel Pads:


Q: How does the Labthink C303H measure the water vapor transmission rate of silica gel pads?

A: The C303H uses a coulometric and infrared sensor method (dry method) where the specimen is placed in a sealed chamber. Controlled dry nitrogen or carrier gas flows, and water vapor transmission is precisely measured, ensuring accurate WVTR results in real time.

Q: What types of materials can be tested with the C303H system?

A: While optimized for silica gel pads, the C303H is also suitable for films and various packaging materials, making it versatile for research, quality control, and packaging development applications.

Q: When is it necessary to calibrate the C303H instrument?

A: Multi-point calibration with traceable standards is recommended upon installation, after significant maintenance, or at scheduled intervals to ensure ongoing measurement accuracy and compliance with ASTM F1249, ISO 15106-2, and JIS K7129.

Q: Where should the Labthink C303H be installed for optimal performance?

A: The system is designed for benchtop or lab table mounting in controlled laboratory conditions (5C-35C, RH 80%). Proper installation ensures consistent results and operational safety.

Q: What is the process for running a measurement on the C303H?

A: Specimens are placed in the quick-clamp, sealed chamber. The touchscreen interface guides through test setup, and automatic measurement begins. Real-time data is displayed, and automatic reports are generated post-test in multiple formats.

Q: How does the C303H system enhance workflow efficiency?

A: With the capacity for testing three specimens simultaneously and features like high throughput automation, automatic data output, and user-friendly controls, the C303H significantly streamlines laboratory testing and data management.

Q: What are the key benefits of using the Labthink C303H for WVTR testing?

A: The C303H delivers high accuracy, repeatability, and real-time analysis, ensures safety with integrated protection systems, and provides automatic documentation, supporting compliance and efficient operation for manufacturers, exporters, and labs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Water Vapor Transmission Rate Tester' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.