Product Description
Product FeaturesNote1
Professional Test Modes to Meet Various Testing Demands
- Multiple independent test modes including tensile test, peel test, tearing test, heat seal test, tensile test at fixed elongation, and compression test, etc. at users choice
- The instrument supports bidirectional testing modes and test speed can be adjusted freely
- Intelligent designs of over-travel protection, overload protect and automatic position reset guarantee safe test operation of the users
Excellent Testing Mechanism & Improved Test Accuracy
- Force measuring system is supplied by top global supplier, which ensures the testing accuracy of better than 0.5% of full scale and guarantees accurate test results and good repeatability. Multiple test ranges can be selected freely.
- Servo control system powered by top global supplier and the patented high-precision ball screw multi-point positioning technology provide displacement accuracy of better than 0.5% of full scale and infinitely variable speed, facilitate the instrument with simplified and stable operation.
- Global renowned brand pneumatic control system supports pneumatic specimen clamping, which avoids the specimen slipping and guarantees the accuracy of test data
High-end, Secure and Easy-to-Use Embedded Computer-controlled System
- Large size touch screen tablet for better viewing and easy operation
- Brand new software and system provide smooth and simplified operating experience
- The system supports displaying and comparison analysis of group of test data as well as unit conversions of test results.
- Labthinks unique data security design by separating the test data from the computer, totally avoids the system software malfunctions caused by computer virus or faulty operations, conforms to the requirements for data traceability of China GMP (optional).
- The instrument is equipped with USB ports and Internet ports for convenient data transmission.
- Unique DataShieldTM system supports centralized management of test data and can be connected to other information management system.
Test StandardNote1
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
C610H is equipped with more than 100 grips for tests of more than 1000 materials. Customization is available for special material tests. Examples of instrument applications:
| Basic Applications |
|
|
- Test of Tensile Strength and Elongation Rate
|
- Test of Tensile Strength at Break
|
|
|
|
|
|
|
|
|
- Tensile Strength Test at Defined Elongation
|
Extended Applications (Additional Accessories Required) |
- Puncture Test of Hypodermic Needles in Artificial Skin
|
|
- Puncture Test of Infusion Bags
|
- Puncture/Pullout Test of Flexible Rubber Closures
|
- Opening Resistance Test of Combined Covers
|
- Tear Test of ZD - Type Caps
|
- Opening Force Test of Oral Liquid Caps
|
- Puncture/Pullout Test of Oral Liquid Caps
|
- 90 Degree Pullout Test of Infusion Bag Caps
|
- Pullout Test of Infusion Bag Caps
|
- 23 Degree Pullout Test of Bottle Caps
|
- Puncture/Pullout Test of Bottle Caps or Rubber Closures
|
- 90 Degree Peel Test of Adhesive Tapes
|
- Tear Resistance Test of Adhesive Binding Books
|
- 90 Degree Peel Test of Water-soluble Plasters
|
- Tear Resistance Test of Adhesives
|
- Adhesive Strength Test (soft)
|
- Adhesive Strength Test (hard)
|
- Peel Test of Flexible Tube Caps
|
- Removal Force of Pipes and Pipe Joints
|
- Pullout Test of Cosmetic Brush Hair
|
- Pullout Test of Tooth Brush Hair
|
- Tensile Strength of Ropes at Break
|
- Opening Force Test of Jelly Cups and Yogurt Cups
|
|
|
- Pullout Test of Rubber Stoppers
|
- 45 Degree Peel Test of Bottle Membranes
|
- Tensile Strength of Sealing Bags
|
- Peel Test of Magnetic Cores
|
- 90 Degree Peel Test of Magnetic Cards
|
- Tear Resistance of Heat Sealing Films
|
- Separating Force of Protection Films
|
- Peel Test of Release Paper
|
- Tear Test Using Trouser Method
|
- Unwrapping Force of Adhesive Tapes
|
- Compressive Resistance of Plastic Bottles
|
|
|
- 135 Degree Peel Test of Plugs
|
- Peeling Grips of Floating Rollers
|
|
|
|
|
|
|
- Tensile Strength of Contact Lenses at Break
|
- Compression Resistance of Jelly Cups
|
- Compression Resistance of Package
|
- Compression Resistance of Sponge
|
|
Technical SpecificationsNote2
| Specifications |
C610H Auto Tensile Tester |
| Load Cell Capacity |
500 N (standard) 50 N, 100 N, 250 N, 1000 N (optional) |
| Accuracy |
0.5% of indicated value (2%FS100%FS) 0.01%FS (0% 2%FS) |
| Resolution |
0.001 N |
| Test Speed |
0.05 500 mm/min |
| Speed Accuracy |
0.5% of indicated value (1%100% of maximum speed) |
| Number of Specimens |
1 |
| Specimen Width |
30 mm (Standard Grip) |
| 50 mm (Optional Grip) |
| Clamping Way |
Pneumatic Specimen Clamp |
| Gas Supply |
Air (outside of supply scope) |
| Gas Supply Pressure |
0.5 MPa 0.7 Mpa (72.5psii101.5psi) |
| Stroke |
1000 mm |
| Instrument Dimension |
500 mm (L) 520 mm (W) 1900 mm (H) |
| Power Supply |
220VAC10% 50Hz / 120VAC10% 60Hz |
| Net Weight |
110 kg |
Configurations
- Standard Configurations
- Instrument, Professional Software, Tablet, Pneumatic Sample Grips
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Customized Grips, Laser Printer, Air Compressor, Computer System required by GMP, DataShieldTM Note3
- Note
- 1. The gas supply port of this instrument is I4mm PU Tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Comprehensive Compliance and Testing PrecisionFully conforming to USP, ISO 8536-4, and key pharmacopeia standards, this system ensures rigorous quality control for non-PVC infusion bags. Multiple testing modes, including pressure, tensile, and leakage, offer detailed assessment of bag integrity and function. Results are delivered through a digital LCD display, ensuring clarity and traceability.
User-Friendly Operation with Enhanced SafetyEquipped with microprocessor controls and an intuitive interface, the system supports both manual and automatic calibration. Safety is enhanced by an interlock system, overcurrent, and overheating protection. The adjustable sample fixture accommodates various bag sizes, ensuring comprehensive testing flexibility.
Efficient Data Management & Real-Time MonitoringThe system stores up to 200 test records and features real-time data monitoring. Automatic alarms signal any out-of-spec results, while data is easily exported or printed via USB/RS232 interfaces for streamlined documentation. This ensures efficient quality reporting and quick decision-making.
FAQ's of Key Quality Control Tests for Non-PVC Infusion Bags:
Q: How does the system ensure compliance with international quality standards for infusion bags?
A: The system is engineered to conform to USP, ISO 8536-4, and relevant pharmacopeia standards. Each test mode and data output is designed to meet these quality benchmarks, ensuring all results are reliable and regulatory-compliant.
Q: What types of tests can be performed on non-PVC infusion bags using this equipment?
A: Users can conduct pressure, tensile, sealing, leakage, and microbial tests on DEHP-free, non-PVC infusion bags. The machine accommodates various testing protocols and provides flexibility in test parameters to meet diverse quality control needs.
Q: When should calibration of the equipment be performed, and what options are available?
A: Calibration can be conducted both automatically and manually, ensuring consistent accuracy. Routine calibration is recommended, especially before critical testing cycles or after major maintenance, to guarantee precise measurements.
Q: Where can data reports be accessed and how can they be exported or printed?
A: Test data is stored digitally within the system's memory (up to 200 records) and can be easily accessed through the LCD interface. Reports are printable and exportable via USB or RS232 ports, facilitating streamlined documentation and compliance reporting.
Q: What is the process to test different bag sizes and materials with the system?
A: The adjustable sample fixture and clamps are designed to securely hold a range of bag sizes and types. Users can select test parameters and customize the fixture based on the infusion bag's dimensions and material, ensuring versatile compatibility.
Q: How does the alarm function benefit laboratory operations?
A: Automatic alarms instantly notify users if any test results fall outside set specifications, ensuring faster corrective action. This reduces the risk of non-conforming products and enhances laboratory responsiveness and product safety.
Q: What are the main benefits of using this Automated QC Test System for manufacturers?
A: Manufacturers benefit from accurate, real-time results, comprehensive compliance, high data security, flexible test modes, and reduced manual intervention. Onsite installation and training further ensure efficient integration and optimized workflow.