Product Description
Product FeaturesNote1
Coulometric Oxygen Sensor
- The instrument is equipped with ppb level Coulometric Oxygen Sensor of Labthink which can obtain lower test limit.
- Designed according to ASTM D3985 with absolute value and no need to calibrate.
- Super long service life, three times longer than traditional Coulometric oxygen sensor.
- Functions of over limit alarm and automatic protection.
Accurate Data
- Using 360 air circulation constant temperature technology, the temperature stability is better.
- Equipped with high-precision temperature and humidity sensor, real-time monitoring and recording temperature and humidity changes.
- In the test process, the automatic control of flow, temperature and relative humidity is realized, and the accuracy is higher.
- Higher test repeatability of 0.01 cc / (m2day) can be achieved.
Effective Three-Cell
- Independent three sets of 50cm2 standard test area cells, in line with the standard requirements for parallel sample detection.
- Three samples are tested at the same time under the same condition, and the data are independent.
- In the same test cycle, the number of samples completed increases from 2 to 3.
- Automatic clamping sample, saving time and labor, clamping force is consistent, better sealing.
Intelligent Operation
- The 12 Inch Touch panel of windows system is used for more convenient operation.
- Automatic mode - after inputting the test temperature and humidity and clicking one key to start the test, the test proceeds automatically.
- New drawer type test cell, one key automatic in-and-out with sound and light reminder.
Safe and Reliable
- Safe Running: the innovative Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus, and ensure the operation reliability and data storage security.
- Safe Operation: equipped with optical and other intelligent sensors as well as sound and light intelligent alarms to ensure the safety of operation.
- Safe Performance: the instrument uses global famous brand with stable and reliable performance.
Powerful Functions
- Professional test mode provides flexible and rich control functions to meet the needs of scientific research.
- Provide oxygen permeability curve, oxygen transmission coefficient curve, temperature curve and humidity curve.
- Ultra wide test range, meet the barrier test (customized) of various materials.
- Ultra wide temperature range, meet the barrier test at different temperatures (customized).
- The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen free carrier gas (optional).
Testing Principle
The sample is clamped between the test chambers, oxygen or air flows on one side of the film, and high-purity nitrogen flows on the other side of the film. Oxygen molecules diffuse through the film into the high-purity nitrogen in the other side. The flowing nitrogen is carried to the sensor. Through the analysis of the oxygen concentration measured by the sensor, the oxygen transmittance is calculated.
Reference Standards
ASTM D3985, ASTM F1307, ASTM F1927(option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Applications
| Applications |
- Films
The oxygen permeability tests of various plastic films, paper plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film like materials.
|
- Sheet
The oxygen permeability tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.
|
Technical Parameters
Table 1: Test Parameters Note2
| Parameters/Model |
C203H |
| Test Scope |
cc/(m2day) (standard area 50cm2) |
0.01200 0.005200 (optional) |
| cc/(m2day) (standard area 50cm2) |
0.01400000Customize |
| cc/(m2day) (MASK area 5cm2) |
0.12000 (optional) |
| cc/(m2day) (MASK area 1cm2) |
0.510000 (optional) |
| Resolving Power |
cc/(m2day) |
0.0001 |
| Repeatability |
cc/(m2day) |
0.01 or1%, whichever is greater |
| Temperature Range |
|
1550 560 (customized) |
| Temperature Fluctuation |
|
0.05 |
| Humidity Range |
%Rh (within standard temperature range) |
O2: 0%5901% Carrier Gas: 0%, 5902% |
| Extended Functions |
GP-01 Gas Purification Unit |
Optional |
| DataShieldTM Data Shield Note 3 |
Optional |
| GMP Computer System Requirements |
Optional |
| CFR21Part11 |
Optional |
Table 2: Technical Specifications
| Test Chamber |
3 sets |
| Sample Size |
4.4 x 4.411.2cm11.2cm |
| Sample Thickness |
120 Mil3mm |
| Standard Test Area |
50cm2 |
| Gas Specification |
99.999% nitrogen, 99.5% oxygen (gas source prepared by the buyer) |
| Air Source Pressure |
40.6 PSI / 280 kPa |
| Interface Size |
1 / 8 "metal tube |
| Dimensions |
23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm) |
| Power Supply |
120VAC 10% 60Hz / 220VAC 10% 50Hz (choose one from those two) |
| Instrument Dimension |
23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm) |
| Net weight |
220Lbs(100kg) |
Table 3: Product Configuration
| Standard Configuration |
Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm |
| Options |
Gp-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements DataShieldTM Data ShieldNote3 |
| Remarks |
The compressed air inlet of the machine is 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the buyer. |
Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.
Product FeaturesNote1
Coulometric Oxygen Sensor
- The instrument is equipped with ppb level Coulometric Oxygen Sensor of Labthink which can obtain lower test limit.
- Designed according to ASTM D3985 with absolute value and no need to calibrate.
- Super long service life, three times longer than traditional Coulometric oxygen sensor.
- Functions of over limit alarm and automatic protection.
Accurate Data
- Using 360 air circulation constant temperature technology, the temperature stability is better.
- Equipped with high-precision temperature and humidity sensor, real-time monitoring and recording temperature and humidity changes.
- In the test process, the automatic control of flow, temperature and relative humidity is realized, and the accuracy is higher.
- Higher test repeatability of 0.01 cc / (m2day) can be achieved.
Effective Three-Cell
- Independent three sets of 50cm2 standard test area cells, in line with the standard requirements for parallel sample detection.
- Three samples are tested at the same time under the same condition, and the data are independent.
- In the same test cycle, the number of samples completed increases from 2 to 3.
- Automatic clamping sample, saving time and labor, clamping force is consistent, better sealing.
Intelligent Operation
- The 12 Inch Touch panel of windows system is used for more convenient operation.
- Automatic mode - after inputting the test temperature and humidity and clicking one key to start the test, the test proceeds automatically.
- New drawer type test cell, one key automatic in-and-out with sound and light reminder.
Safe and Reliable
- Safe Running: the innovative Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus, and ensure the operation reliability and data storage security.
- Safe Operation: equipped with optical and other intelligent sensors as well as sound and light intelligent alarms to ensure the safety of operation.
- Safe Performance: the instrument uses global famous brand with stable and reliable performance.
Powerful Functions
- Professional test mode provides flexible and rich control functions to meet the needs of scientific research.
- Provide oxygen permeability curve, oxygen transmission coefficient curve, temperature curve and humidity curve.
- Ultra wide test range, meet the barrier test (customized) of various materials.
- Ultra wide temperature range, meet the barrier test at different temperatures (customized).
- The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen free carrier gas (optional).
Testing Principle
The sample is clamped between the test chambers, oxygen or air flows on one side of the film, and high-purity nitrogen flows on the other side of the film. Oxygen molecules diffuse through the film into the high-purity nitrogen in the other side. The flowing nitrogen is carried to the sensor. Through the analysis of the oxygen concentration measured by the sensor, the oxygen transmittance is calculated.
Reference Standards
ASTM D3985, ASTM F1307, ASTM F1927(option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Applications
| Applications |
- Films
The oxygen permeability tests of various plastic films, paper plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film like materials.
|
- Sheet
The oxygen permeability tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.
|
Technical Parameters
Table 1: Test Parameters Note2
| Parameters/Model |
C203H |
| Test Scope |
cc/(m2day) (standard area 50cm2) |
0.01200 0.005200 (optional) |
| cc/(m2day) (standard area 50cm2) |
0.01400000Customize |
| cc/(m2day) (MASK area 5cm2) |
0.12000 (optional) |
| cc/(m2day) (MASK area 1cm2) |
0.510000 (optional) |
| Resolving Power |
cc/(m2day) |
0.0001 |
| Repeatability |
cc/(m2day) |
0.01 or1%, whichever is greater |
| Temperature Range |
|
1550 560 (customized) |
| Temperature Fluctuation |
|
0.05 |
| Humidity Range |
%Rh (within standard temperature range) |
O2: 0%5901% Carrier Gas: 0%, 5902% |
| Extended Functions |
GP-01 Gas Purification Unit |
Optional |
| DataShieldTM Data Shield Note 3 |
Optional |
| GMP Computer System Requirements |
Optional |
| CFR21Part11 |
Optional |
Table 2: Technical Specifications
| Test Chamber |
3 sets |
| Sample Size |
4.4 x 4.411.2cm11.2cm |
| Sample Thickness |
120 Mil3mm |
| Standard Test Area |
50cm2 |
| Gas Specification |
99.999% nitrogen, 99.5% oxygen (gas source prepared by the buyer) |
| Air Source Pressure |
40.6 PSI / 280 kPa |
| Interface Size |
1 / 8 "metal tube |
| Dimensions |
23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm) |
| Power Supply |
120VAC 10% 60Hz / 220VAC 10% 50Hz (choose one from those two) |
| Instrument Dimension |
23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm) |
| Net weight |
220Lbs(100kg) |
Table 3: Product Configuration
| Standard Configuration |
Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm |
| Options |
Gp-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements DataShieldTM Data ShieldNote3 |
| Remarks |
The compressed air inlet of the machine is 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the buyer. |
Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.
High-Precision Testing for Packaging SolutionsAchieve reliable oxygen transmission measurements for fruit and vegetable packaging with our advanced tester. The electrochemical sensor ensures precision, while adjustable test parameters suit various packaging materials. By assessing oxygen barrier properties, users can enhance shelf life and maintain product quality.
Customizable Testing EnvironmentTailor the test environment with adjustable gas mixture, concentration, temperature (15C50C), and humidity (1090% RH) controls. This flexibility addresses diverse testing requirements for packaging producers, exporters, and quality control labs.
Efficient Data Management and ConnectivityBenefit from real-time and batch data export, proprietary software compatibility, and storage of up to 1000 test datasets. With RS232 and USB interfaces, integrating data into your existing workflow is seamless, improving reporting efficiency and traceability.
FAQs of Measuring Oxygen Transmission Rate for Optimal Fruit and Vegetable Packaging:
Q: How does the oxygen transmission rate tester benefit fruit and vegetable packaging quality control?
A: The tester accurately measures the oxygen permeability of packaging materials, ensuring optimal barrier properties. This helps prevent spoilage, extend shelf life, and maintain the freshness of fruits and vegetables during storage and transport.
Q: What is the principle behind oxygen transmission rate measurement in this equipment?
A: It utilizes the coulometric sensor method under equal pressure, with an electrochemical oxygen sensor that detects and quantifies oxygen permeating through the specimen, providing highly precise results in real-time or batch modes.
Q: When and where should this tester be used for packaging analyses?
A: This instrument is ideal for use during packaging development, routine quality checks, and research in laboratory or industrial settings. Its suitable for manufacturers, exporters, and suppliers seeking to ensure the integrity of fruit and vegetable packaging.
Q: What is the process for running a test with this instrument?
A: Place the specimen in the corrosion-resistant chamber, set the desired gas mixture, temperature, and humidity. Start the automated test using the microcomputer control. The device will monitor and display results digitally, sounding an alarm if parameters are out of range.
Q: How is test data managed and exported from the system?
A: Test results can be monitored in real time and exported in batches via proprietary software to an external PC using RS232 or USB interfaces. The device stores up to 1000 datasets, ensuring comprehensive traceability and record-keeping.
Q: What calibration options and measures ensure result accuracy?
A: The tester offers both internal and external calibration modes, supporting regular and precise maintenance. Auto-calibration and high-resolution detection (0.01 cc/m24h) ensure consistent and accurate measurements.
Q: What are the usage benefits of the corrosion-resistant stainless steel chamber and compact design?
A: The stainless steel chamber reduces maintenance, resists corrosion from custom gas mixtures, and ensures reliable long-term performance. The compact benchtop design allows for easy integration into a variety of laboratory and industrial testing environments.