Product Description
Product FeaturesNote1
Accurate Data
- Brand new dome design test chamber and 360 air circulation constant temperature technology ensures better temperature stability.
- Imported high-precision vacuum sensor can accurately test ultra-high barrier materials with 0.01i0.09cm3/ m324h0.1MPa test range.
- Imported pneumatic control system has a low failure rate and an ultra-long service life, ensuring good overall system air tightness and high test accuracy.
- Imported vacuum pump can reach 0.2Pa extreme pressure with increased vacuum rate.
- The vacuum pump is controlled automatically by the system without manual opening and closing, increases efficiency and saves labor.
- Labthinks unique high-precision automatic pressure compensation technology in the test process realizes a constant pressure difference in the high-pressure chamber, and the pressure fluctuation is less than 0.2 kPa.
- The pressure in high-pressure chamber can be set within the range of 10kPa210kPa, the pressure can be maintained accurately and stably by the system.
High Efficiency
- Six independent test cells with standard area, three times the number of test cells in traditional oxygen permeability testing instruments.
- Six specimens can be tested simultaneously under the same testing condition, delivering independent test result.
- Medium and low barrier materials, test time <4 hours (including vacuumize time).
- High barrier materials, test time <4 hours (including vacuumize time).
- Automatic specimen clamping saves time and effort. The clamping force is consistent, resulting in better air tightness.
Intelligent control
- 12 touch-screen tablet powered by WindowsTM 10 operating system makes the operation simpler and more convenient.
- Automatic test mode requires only inputting temperature and humidity, one click start, the test is fully automated.
- Intelligent test chamber hood automatically opens and closes with sound and light alert
Safe and reliable
- System security -- Built-in Labthink's unique high-end industrial computer prevents system failures caused by computer viruses, ensures operational reliability and data storage security.
- Operation safety-- Equipped with intelligent optics sensors which give sound and light alert to ensure safe operation.
- Performance reliabilitythe instrument adopts components of global renowned brands, to ensure stable and reliable performance.
Space saving
- The width of the instrument is only 1/3 of the traditional six-cell instrument, saving space for a laboratory.
Powerful functions
- Professional test mode provides flexible and diverse control options to meet various needs of scientific research.
- The system provides gas transmission rate curve, gas transmission coefficient curve, and temperature curve.
- Ultra-wide test temperature range to enable the barrier tests under various extreme temperature (Optional).
- Ultra-wide test range to meet the barrier test of various materials (customize).
- Tests of hazardous gases such as H2aCH4 are applicable (Customize).
Test Principle
The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.
Standard
ISO 15105-1aISO 2556aGB/T 1038-2000aASTM D1434aJIS K7126-1aYBB 00082003
Applications
| Applications |
- Films
Gas transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films, glass fiber aluminum foil composite films and many others
|
- Sheets
Gas transmission rate test of PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheet materials
|
Technical Specifications
Table 1: Test Parameters Note2
| Parameters/Model |
C106H |
| Test range |
cm3/m224h0.1MPa |
0.01i50,000 |
| Resolution |
cm3/m224h0.1MPa |
0.001 |
| Test temperature |
|
15i50i145i60i14Optionali14 |
| Temperature resolution |
|
0.01 |
| Temperature fluctuation |
|
0.15 |
| Test humidity |
%RHi14Within standard test temperature rangei14 |
0%i145i902%i14Customizei14 |
| Vacuum Resolution |
Pa |
0.01 |
| Vacuum Accuracy |
Pa |
0.2%i141%-100% of Full Scalei14 |
| Vacuum Degree of Test Chamber |
Pa |
10 |
| Additional Functions |
DataShieldTM note3 |
Optional |
| GMP Computer System requirement |
Optional |
| CFR21Part11 |
Optional |
Table 2: Technical Specifications
| Test Cell |
6 Cells |
| Specimen Size |
4.6 x 4.6i1411.7cm11.7cmi14 |
| Specimen Thickness |
120 Mili143mmi14 |
| Standard test area |
38.48cm2 |
| Test Gas |
O2aN2aCO2 etc.i14Outside of supply scopei14 |
| Test Pressure |
10 kPa210 kPai14Can be set betweeni14 |
| Pressure Fluctuation |
0.2 kPa |
| Gas Pressure |
79.7 PSI / 550 kPa |
| Port Size |
I6 mm PU tubing |
| Instrument Dimension |
23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm) |
| Power Supply |
120VAC10% 60Hz/220VAC10% 50Hzi14one of twoi14 |
| Net Weight |
220Lbsi14100kgi14 |
Table 3: Product Configuration
| Standard Configuration |
Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, I6 mm PU tubing |
| Optional Parts |
Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3 |
| Note |
The gas compressor port of the instrument is I6 mm PU tubingi14pressure79.7 PSI/ 550kPai14, customers need to prepare gas supply. |
Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
Designed for Accurate Film Permeability TestingUtilizing advanced precision gas sensors and a stainless steel test chamber, this instrument measures the permeability coefficient of film materials reliably. It accommodates a broad sample size and supports both continuous and batch testing, making it suitable for diverse applications in quality assurance, R&D, and manufacturing.
Intelligent Operation and Data ManagementEquipped with automatic calibration using standard gases, microcomputer control, and internal memory storage, the instrument ensures high accuracy and hassle-free operation. Integration with PCs is streamlined through RS232 and USB, allowing seamless data export for further analysis and documentation.
Comprehensive Safety and Environmental ComplianceWith built-in safety measures against overload, leakage, and over-voltage, the instrument ensures operator security. Additionally, it meets RoHS and CE standards, and performs efficiently within a 5-40C ambient temperature and 10-90% relative humidity, making it suitable for global laboratory and industrial environments.
FAQ's of Film Material Permeability Coefficient Measuring Instrument:
Q: How does the instrument calibrate itself automatically?
A: The instrument features automatic calibration using certified standard gases, ensuring that daily measurements remain accurate. This process is handled by the microcomputer control system, requiring minimal user intervention and reducing the risk of manual calibration errors.
Q: What is the process for measuring a film's gas permeability using this equipment?
A: To measure gas permeability, place a prepared specimen (up to 100100 mm) inside the 2-liter stainless steel test chamber. Select the desired test mode-continuous or batch-via the digital LCD display. The instrument then controls gas flow and pressure, collects the data, and provides results within seconds.
Q: Where can I access and export my test data?
A: Test results and data are automatically saved in the device's internal memory. You can export this data to a PC using either the RS232 or USB interface for record-keeping, analysis, or generating test reports.
Q: What safety features protect users during operation?
A: The instrument is designed with multiple safety protections, including automatic shutdown in the event of overload, gas leakage, or over-voltage conditions. These features help ensure safe operation in laboratory and industrial settings.
Q: When is this instrument most beneficial to use?
A: This measuring instrument is ideal for routine quality control in manufacturing, research and development projects, and material certification processes. Its high accuracy and automation are especially beneficial when frequent, repeatable, or multi-point measurements are required.
Q: What are the benefits of the microcomputer control and digital display?
A: Microcomputer control provides precise automation and reliable data processing, streamlining complex test procedures. The digital LCD makes setting up tests simple and offers clear real-time feedback on status and results, improving operational efficiency.
Q: How does the instrument ensure accuracy and environmental compliance?
A: The system maintains high measurement accuracy (1%) via precision sensors and regular automatic calibration. Constructed with RoHS- and CE-compliant components, it also operates effectively across a wide range of ambient temperatures and humidity conditions.