Packaging Permeation Tests to Ensure Food and Medicine Freshness

Packaging Permeation Tests to Ensure Food and Medicine Freshness

50000 USD ($)/Set

Product Details:

  • Display Type Digital Touchscreen
  • Specimen Size 50 mm, 100 mm, Customizable
  • Test Range 0.01~50000 cm/m24h0.1MPa
  • Humidity 30%~90% RH
  • Automation Grade Automatic
  • Mounting Type Benchtop
  • Equipment Type Permeation Test Instrument
  • Click to View more
X

Packaging Permeation Tests to Ensure Food and Medicine Freshness Price And Quantity

  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set
  • 1 Set

Packaging Permeation Tests to Ensure Food and Medicine Freshness Product Specifications

  • Approx. 60 kg
  • Standard 6 mm
  • Up to 300 mm
  • 1-3 (Customizable)
  • 15C~50C
  • 220V
  • High Sensitivity Sensors, Real-Time Data, Auto Calibration, Multi-Layer Film Support
  • Food and Medicine Packaging Freshness Testing
  • 0.01 cm/m24h
  • 500 Tests/Day
  • 50 Hz
  • 220V 50Hz
  • RS232, USB
  • 3 Seconds
  • 0 ~ 300 mm
  • 400 mm
  • 0.01~50000 cm/m24h0.1MPa
  • 0.6 MPa
  • Digital Touchscreen
  • 0.01~50000 cm/m24h0.1MPa
  • 50 mm, 100 mm, Customizable
  • Microcomputer/Program Control
  • Permeation Test Instrument
  • Benchtop
  • 0.001 cm/m24h
  • 30%~90% RH
  • 0.01 ~ 10 mm/min Adjustable
  • Lab Testing Equipment
  • Automatic

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Using 360 air circulation constant temperature technology, the temperature stability is better.
  • Equipped with high-precision temperature and humidity sensor, to monitor and record temperature and humidity changes in real time.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • Higher test repeatability of 0.01 cc / (m2day) can be achieved.

High Efficiency Three-cell

  • Independent three sets of 50cm2 standard area test cells, in line with parallel sample detection required by standards.
  • Three samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 3.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • New drawer type test cell, one key automatic in-and-out with sound and light reminder.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C403H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.01 200
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.01 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.005 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.005 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.05
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 test chambers
Specimen Size 4.4 x 4.4i1411.2cm11.2cm)
Specimen Thickness 120 Mili143mmi14
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzi14either one of twoi14
Instrument Dimensions 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm)
Net weight 220Lbsi14100kgi14

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument isI 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Precise and Versatile Testing

The instrument accommodates a wide variety of packaging films-including plastic, foil, composite, and paper-ensuring versatility in meeting testing standards for the food and pharmaceutical industries. With adjustable test speeds and specimen sizes, it can analyse between 1 and 3 samples simultaneously and reports results within seconds, offering laboratories flexibility and efficiency.


Advanced Features for Reliable Results

Equipped with programmable microcomputer control, built-in over-limit alarm, high-accuracy sensors, and real-time data display, this permeation tester delivers highly accurate, repeatable results. Auto calibration every six months and digital touchscreen operation streamline workflow and minimize operator errors, ensuring consistent quality assurance.


Efficient Data Management and Compatibility

The system stores up to 2000 test results and is compatible with Windows OS, allowing seamless integration into modern laboratory settings. Data can be exported via RS232 and USB interfaces, making report generation and compliance tracking simple and efficient.

FAQ's of Packaging Permeation Tests to Ensure Food and Medicine Freshness:


Q: How does the permeation test instrument ensure the freshness of food and medicine packaging?

A: By measuring the rate at which gases such as oxygen, carbon dioxide, or nitrogen pass through packaging materials, the instrument detects potential breaches or weaknesses that could compromise product freshness, allowing manufacturers to ensure optimal barrier performance for food and medicine safety.

Q: What types of packaging materials can I test with this instrument?

A: This permeation tester supports plastic, foil, composite, and paper membranes. Its multi-layer film support and customizable specimen sizes make it suitable for a broad range of packaging formats encountered in the food and pharmaceutical sectors.

Q: When should the calibration of the instrument be performed?

A: For precise and reliable results, calibration should be performed every six months, as guided by the auto-calibration system in the tester. Regular calibration helps maintain measurement accuracy and compliance with laboratory standards.

Q: What is the typical process for conducting a permeation test with this equipment?

A: Users select the gas type, set specimen size, and configure test parameters via the digital touchscreen or microcomputer. After mounting up to three samples, the system automatically manages gas flow and conditions, displays real-time data, and stores up to 2000 measurement records. Alarms notify users of any over-limit results during testing.

Q: Where is this permeation test instrument best utilized?

A: This equipment is intended for laboratory environments focused on quality control, research and development, and compliance testing in food and medicine packaging industries. Its benchtop design and automatic operation make it ideal for extensive daily testing.

Q: What are the main benefits of using this permeation tester?

A: Users benefit from high sensitivity, adjustable test parameters, rapid response (3 seconds), real-time digital monitoring, and extensive data storage. Its flexibility in supporting multiple gas types and materials, along with software compatibility and automatic calibration, makes quality assurance more efficient.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail