Call Us
Send Inquiry    Call Me Free
Testing Protein-Based Films Water Vapor and Oxygen Barrier Performance

Testing Protein-Based Films Water Vapor and Oxygen Barrier Performance

50000 USD ($)/Set

Product Details:

  • Specimen Size 80 mm x 80 mm
  • Accuracy 2% of Reading
  • Humidity 20%90% RH
  • Interface Type RS232/USB
  • Application Testing protein-based films water vapor & oxygen barrier performance
  • Max Height 400 mm
  • Measuring Range 0.1100 g/m24h (water vapor), 0.110 cc/m24h (oxygen)
  • Click to View more
X

Testing Protein-Based Films Water Vapor and Oxygen Barrier Performance Price And Quantity

  • 1 Set
  • 50000.00 - 100000.00 USD ($)/Set
  • 50000 USD ($)/Set

Testing Protein-Based Films Water Vapor and Oxygen Barrier Performance Product Specifications

  • Automatic
  • 0.4 MPa
  • 0.01 g/m24h
  • Fully automatic, programmable tests, data logging
  • 15C50C
  • Research, Food Packaging, Pharmaceutical Films
  • Laboratory Tester
  • 30 seconds
  • 50 Hz
  • 13 samples
  • 100900 mm
  • AC 220V
  • 3 L/min
  • 220 V AC 10%, 50 Hz
  • Bench Top
  • 1/8 inch
  • 300 mm
  • 400 mm
  • Testing protein-based films water vapor & oxygen barrier performance
  • RS232/USB
  • Microcomputer Controlling
  • 48 kg
  • 20%90% RH
  • 2% of Reading
  • 80 mm x 80 mm
  • 20-100 mm/min
  • LCD Digital Display
  • 0.1100 g/m24h (water vapor), 0.110 cc/m24h (oxygen)
  • 0.01100 g/m24h (water vapor), 0.0110 cc/m24h (oxygen)

Product Description

Product Featuresnote1

OTR/WVTR tested in One Instrument

  • OTR \ WVTR mode, OTR mode and WVTR mode are available for selection.
  • OTR and WVTR tests can be automatically completed for each sample mounting.
  • Genuinely reflect the OTR \ WVTR performance of the same sample, avoiding effect on test data due to sample contamination arising from instrument switching.

Coulometric Oxygen Sensor

  • The instrument is equipped with a ppb level Coulometric Oxygen Sensor, as one of new Labthink technical achievements, which can obtain a lower limit of the test.
  • Designed according to ASTM D3985 with absolute value, and no calibration is permitted.
  • Longer service life, two times longer than that of a traditional Coulometric oxygen sensor.
  • Over limit alarm and automatic protection.

Infrared Moisture Sensor

  • The instrument is equipped with Labthink patented infrared moisture sensor which can obtain a lower limit of the test.
  • Designed according to ASTM F1249.
  • Longer service life, non-consumable.
  • Over limit alarm and automatic protection.

Accurate Data

  • Brand new rainbow bridge structural test cell and 360 air circulation constant temperature technology ensure better temperature stability.
  • In the test process, the automatic control on flow, temperature and relative humidity is realized, reaching higher accuracy.
  • The test cell is equipped with a high-precision humidity sensor to monitor and record humidity changes in real time.

High Efficiency 6 Test Cells

  • Independent six sets of 50cm2 standard area test cells, which is three times the traditional oxygen transmission rate test instrument.
  • Six samples can be tested at the same time under the same conditions, with independent tests data.
  • In the same test cycle, the number of samples completed increases from 2 to 6.
  • Automatic sample clamping, saving time and effort, ensuring consistent clamping force and better sealing.

Intelligent Operation

  • The 12 Inch Touch panel of windows system is used for more convenient operation.
  • Automatic mode - after inputting test temperature and humidity and clicking one key, the test proceeds automatically.
  • Intelligent test cell hood which opens and closes automatically with sound and light alert.

Safe and Reliable

  • Safe Running: Labthinks high-end industrial computer is embedded to eliminate the system failure caused by computer virus and ensure the operation reliability and data storage security.
  • Safe Operation: equipped with optical and other intelligent sensors as well as intelligent sound and light alarms to ensure the operation safety.
  • Safe Performance: the instrument uses global renowned brand components with stable and reliable performance.

Space Saving

  • The width of the instrument is only 1/3 of the traditional six-cell instrument, saving laboratory space.

Powerful Functions

  • Professional test mode provides flexible and plentiful control functions to meet the needs of scientific research.
  • Display oxygen/water vapor transmission rate curve, oxygen/water vapor transmission coefficient curve, temperature curve and humidity curve.
  • Wide temperature range, allowing the barrier test at different temperatures (customized).
  • The gas purification device independently developed by Labthink can remove trace oxygen in nitrogen, providing oxygen-free carrier gas (optional).

Testing Principle

The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.

Reference Standards

ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015

ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015

Test Applications

Applications
  • Films
    The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
  • Sheets
    The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.

Technical Specifications

Table 1: Test Parameters Note2

Parameter/Model Model C406H
OTR Test Range cc/(m2day) (Standard area 50cm2) 0.02 200
cc/(m2day) (MASK area 1cm2) 1 10000 (Optional)
cc/(m2day) (MASK area 5cm2) 0.2 2000 (Optional)
OTR Resolution cc/(m2day) 0.0001
OTR Repeatability cc/(m2day) 0.02 or 1%, whichever is greater
WVTR Test Range g/(m2day) (Standard area 50cm2) 0.02 40
g/(m2day) (MASK area 5cm2) 0.2 400 (Optional)
g/(m2day) (MASK area 1cm2) 1 2000 (Optional)
WVTR Resolution g/(m2day) 0.0001
WVTR Repeatability g/(m2day) 0.02 or 2%, whichever is greater
Temperature range C 15 - 50
5 60 (Customized)
Temperature fluctuation C 0.15
Humidity range %RH (Within standard temperature range) 0%, 5 - 902%, 100%
Extended functions GP-01 Gas Purification Unit Optional
DataShieldTM Note3 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 6 test chambers
Specimen Size 4.6 x 4.611.7cm11.7cm)
Specimen Thickness 120 Mil3mm
Standard Test Area 50 cm2
Carrier Gas 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure 40.6 PSI / 280 kPa
Port Size 1/8 inch metal tubing
Power Supply 120VAC10% 60Hz / 220VAC10% 50Hzeither one of two
Instrument Dimensions 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm)
Net weight 220Lbs100kg

Configurations

Standard Configurations
Mainframe, tablet, sampler, vacuum grease, polyurethane pipe of 6 mm in diameter
Optional Parts
GP-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements and DataShieldTM Data ShieldNote3
Remarks
1. The gas supply port of the instrument is 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa);
2. Customers will need to prepare for gas supply and distilled water.

Note 1: All the product features are subject to detailed descriptions in the "Technical Parameters.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.



Reliable Barrier Performance Analysis

Assessing water vapor and oxygen transmission in protein-based films is crucial for preserving product integrity. This tester provides accurate, repeatable results essential for evaluating packaging quality in research and manufacturing environments. Compliance with ASTM E96 and ASTM D3985 ensures industry-standard testing.


Cutting-Edge Automated Testing

With fully programmable, automatic operations and advanced data logging, the instrument streamlines testing procedures. Automatic calibration, microcomputer control, and immediate LCD display feedback optimize workflow and guarantee consistency for up to three simultaneous samples.


Comprehensive Data Handling and Integration

USB and RS232 interfaces enable easy data transfer to laboratory networks, while integrated software simplifies result management and record-keeping. The systems print feature supports documentation, and compliance reporting remains effortless for research and quality control teams.

FAQs of Testing Protein-Based Films Water Vapor and Oxygen Barrier Performance:


Q: How does the Laboratory Tester measure the water vapor and oxygen barrier performance of protein-based films?

A: The tester employs gravimetric methods for water vapor transmission and coulometric principles for oxygen barrier assessment. It evaluates samples up to 3 mm thick, providing precise readings for packaging films resistance to water and oxygen permeation under controlled temperature and humidity.

Q: What test standards does this equipment comply with and why is it important?

A: This instrument complies with ASTM E96 for water vapor transmission and ASTM D3985 for oxygen transmission rate. Compliance guarantees that measurement results are internationally recognized and suitable for regulatory, research, and industry applications.

Q: When is automated calibration performed and what are its benefits?

A: Automatic calibration is conducted before each test or as scheduled by the software, ensuring data accuracy and consistency. This reduces operator error, saves time, and provides reliable, repeatable results with minimal user intervention.

Q: Where can this laboratory tester be used?

A: The tester is ideally suited for use in research institutes, food packaging labs, pharmaceutical film testing, quality control laboratories, and production facilitiesall environments where evaluating moisture and oxygen barrier properties is essential.

Q: What is the process for testing a film sample with this equipment?

A: A film specimen (80 mm x 80 mm) is mounted in the stainless steel chamber. The test parameters are programmed via the microcomputer interface. The machine then measures barrier properties, with data collected through automated sensors. Results are displayed and can be exported or printed via USB or RS232.

Q: How can users benefit from the software integration and data handling features?

A: Software integration facilitates seamless control, data logging, and report generation. Users can easily transfer results for further analysis, maintain a digital archive, and enhance efficiency by automating records managementall crucial for research validation and regulatory compliance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'OTR/WVTR Test System' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.